How to Develope a Novel 3D Printed Integral Customized Anatomical Acetabular Prosthesis in Hip Arthroplasty for Crowe Type II and III Developmental Dysplasia of the Hip?

Zhang, H.; Ma, X.; Cheng, Z.; Li, X.; Zhou, J.; Zhao, J.

2022-11-30 orthopedics
10.1101/2022.11.28.22282849 medRxiv
Show abstract

BackgroundThe acetabular pathomorphology in patients with Crowe type II and III developmental dysplasia of the hip(DDH)often present complicated changes, which bring challenges to the anatomical reconstruction of acetabulum in total hip arthroplasty (THA). The objective of this study was to develope a novel 3D printed integral customized acetabular prosthesis, which provides a promising way to reconstruct the acetabulum with higher accuracy and efficiency by digital softwares, compared with previous 3D printing model method. Methods15 patients (18 hips) with end-stage hip osteoarthritis due to Crowe type II/III DDH who underwent primary cementless THA from January 2015 to November 2021 were included. The 15 patients consisted of 3 men (3 hips) and 12 women (15 hips) with an average age of 53.89 {+/-} 8.48 years (range from 32 to 69 years). The novel 3D printed integral customized acetabular prosthesis was designed by the model method and software method respectively. The indicators of the cup size, the volume and superficial area of bone defect, the inclination and anteversion of acetabular cup, the horizontal and vertical distance of hip center and working time were compared between two methods. ResultsThere were statistically significant difference between the software group and model group on the volume and superficial area of bone defect as well as working time (t = 2.397, 2.707,138.509, P < 0.05). The mean anteversion and inclination of acetabular cup in the software group and model group were(15.17{+/-}0.52){degrees},(40.24{+/-}0.58){degrees}and (33.79 {+/-}13.43){degrees}, (30.50 {+/-}11.03){degrees}respectively, the difference was statistically significant (t = 5.859, 3.767, P < 0.05).There were no statistically significant difference between the software group and model group on cup size, the horizontal and vertical distance of hip center(t =1.458,0.114, 1.712, P > 0.05) ConclusionsThe application of digital softwares could design and develope the novel 3D printed integral customized anatomical acetabular prosthesis in THA for {square}Crowe type II and III DDH with high accuracy and efficiency.

Matching journals

The top 5 journals account for 50% of the predicted probability mass.

1
PLOS ONE
4510 papers in training set
Top 4%
24.2%
2
Medicine
30 papers in training set
Top 0.1%
9.0%
3
Applied Sciences
24 papers in training set
Top 0.1%
9.0%
4
Cureus
67 papers in training set
Top 0.4%
6.8%
5
Scientific Reports
3102 papers in training set
Top 14%
6.8%
50% of probability mass above
6
Medical Physics
14 papers in training set
Top 0.1%
5.2%
7
Computational and Structural Biotechnology Journal
216 papers in training set
Top 2%
2.8%
8
BMJ Open
554 papers in training set
Top 7%
2.8%
9
JMIR Medical Informatics
17 papers in training set
Top 0.5%
2.2%
10
Annals of Biomedical Engineering
34 papers in training set
Top 0.5%
1.9%
11
BioMed Research International
25 papers in training set
Top 1%
1.8%
12
Bioengineering
24 papers in training set
Top 0.3%
1.8%
13
Sensors
39 papers in training set
Top 0.9%
1.8%
14
Journal of Clinical Medicine
91 papers in training set
Top 3%
1.8%
15
Frontiers in Human Neuroscience
67 papers in training set
Top 1%
1.8%
16
JAMIA Open
37 papers in training set
Top 0.9%
1.4%
17
Osteoarthritis and Cartilage
30 papers in training set
Top 0.3%
1.3%
18
Biochemical and Biophysical Research Communications
78 papers in training set
Top 0.9%
1.3%
19
Frontiers in Medicine
113 papers in training set
Top 6%
0.8%
20
Frontiers in Bioengineering and Biotechnology
88 papers in training set
Top 3%
0.7%
21
PeerJ
261 papers in training set
Top 18%
0.5%
22
Biomedicines
66 papers in training set
Top 4%
0.5%
23
BMC Medicine
163 papers in training set
Top 8%
0.5%