Artificial intelligence-based automated left ventricular mass quantification from non-contrast cardiac CT scans: correlation with contrast CT and cardiac MRI
Han, D.; Shanbhag, A.; Miller, R. J. H.; Kwok, N.; Waechter, P.; Builoff, V.; Newby, D. E.; Dey, D.; Berman, D. S.; Slomka, P.
Show abstract
BackgroundNon-contrast CT scans are not used for evaluating left ventricle myocardial mass (LV mass), which is typically evaluated with contrast CT or cardiovascular magnetic resonance imaging (MRI). We assessed the feasibility of LV mass estimation from standard, ECG-gated, non-contrast CT using an artificial intelligence (AI) approach and compare it with coronary CT angiography (CTA) and cardiac MRI. MethodsWe enrolled consecutive patients who underwent coronary CTA, which included non-contrast CT calcium scanning and contrast CTA, and cardiac MRI. The median interval between coronary CTA and MRI was 22 days (IQR: 3-76). We utilized an nn-Unet AI model that automatically segmented non-contrast CT structures. AI measurement of LV mass was compared to contrast CTA and MRI. ResultsA total of 316 patients (Age: 57.1{+/-}16.7, 56% male) were included. The AI segmentation took on average 22 seconds per case. An excellent correlation was observed between AI and contrast CTA LV mass measures (r=0.84, p<0.001), with no significant differences (136.5{+/-}55.3 vs. 139.6{+/-}56.9 g, p=0.133). Bland-Altman analysis showed minimal bias of 2.9. When compared to MRI, measured LV mass was higher with AI (136.5{+/-}55.3 vs. 127.1{+/-}53.1 g, p<0.001). There was an excellent correlation between AI and MRI (r=0.85, p<0.001), with a small bias (-9.4). There were no statistical differences between the correlations of LV mass between contrast CTA and MRI, or AI and MRI. ConclusionsThe AI-based automated estimation of LV mass from non-contrast CT demonstrated excellent correlations and minimal biases when compared to contrast CTA and MRI.
Matching journals
The top 6 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Evaluation of the second-generation whole-heart motion correction algorithm (SSF2) used to demonstrate the aortic annulus on cardiac CT 97%
- Reduced stress perfusion in myocardial infarction with nonobstructive coronary arteries 97%
- Improved evaluation of left ventricular hypertrophy using the spatial QRS-T angle by electrocardiography 96%
Similar papers in this journal
- {-}CardiOvascular examination in awake Orangutans (Pongo pygmaeus pygmaeus): Low-stress Echocardiography including Speckle Tracking imaging (the COOLEST method) 95%
- Mechanical effects of MitraClip on leaflet stress and myocardial strain in functional mitral regurgitation: A finite element modeling study. 95%
- Predictors and outcomes of Cardiac Dyssynchrony among patients with heart failure attending Benjamin Mkapa Hospital in Dodoma, central Tanzania: A protocol of prospective-longitudinal study 94%
Similar papers in this journal
- Non-Invasive Scale Measurement of Cardiac Output Compared with the Gold-Standard Direct Fick Method: A Feasibility Study 95%
- Patient Screening for Self-Expanding Percutaneous Pulmonary Valves using Virtual Reality 94%
- Relationship of mild to moderate impairment of left ventricular ejection fraction with fatal ventricular arrhythmic events in cardiac sarcoidosis 94%
Similar papers in this journal
- Response of the Myocardium to Hypertrophic Conditions in the Adult Population: The Prospective Observational REMODEL Cohort Study Protocol 96%
- Early Structural Cardiovascular Disease, HIV, and Tuberculosis in East Africa (ASANTE): Cross-sectional study protocol for a multimodal cardiac imaging study in Nairobi, Kenya 93%
- Performance of digital Early Warning Score (NEWS2) in a cardiac specialist setting: retrospective cohort study 93%
Similar papers in this journal
- Detection, Isolation and Quantification of Myocardial Infarct with Four Different Histological Staining Techniques 95%
- Transparent and robust Artificial intelligence-driven Electrocardiogram model for Left Ventricular Systolic Dysfunction 93%
- Safety of anti-thrombotic therapy in acute aortic dissection; single center, observational study 92%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.