Comparative evaluation of serum lithium estimation in serum samples using plain glass vial and serum clot activator vacutainer by reflectance photometry principle.
Sahu, P. K.; Sahoo, S.; Chatterjee, N.; Majhi, J.; Dutta, A. K.; Goswami, K.; Pal, A.
Show abstract
BackgroundThe collection of blood samples in different vacutainers can affect the result of serum lithium estimation due to the presence of distinct additives added in the blood collection vacutainer for enhancing the clot formation process. The presence of these additives has proven to interfere with laboratory results of biochemical analytes. In this case, both the pre-analytical and the analytical phases have a significant impact on the accuracy and precision of the test result. Thus, it has become a challenge for the lab physician to estimate lithium in any clinical laboratory setup. Materials and MethodsIn total, 100 patient samples were collected and paired into clot activator vacutainers and plain glass vials. Both the paired collecting tubes after centrifugation were processed immediately via Vitros 4600 analyzer working on the principle of reflectance photometry. Both the paired tubes were stored at 2-8 degrees centigrade and were further analyzed, at 24 and 48 hours respectively, from the time of their collection. The statistical analysis was done in IBM(R) SPSS(R) software version 23. ResultsThere was a significant difference in the lithium values obtained from clot activator vacutainers in comparison to glass vial. The difference between the measurements of the lithium levels was statistically tested by t test where it was observed that the lithium measurements by the two different collecting tubes differed significantly with a Confidence Interval of 0.03 to 0.06 implying the level of agreement of both the methods are not similar. But there was no statistical difference in the lithium values estimated at 24 hours and 48 hours of collection. ConclusionIn this study, lithium levels measured by clot-activated vacutainers are found to be low as compared to lithium levels measured through glass vials. There is no apparent change in lithium values obtained at 1hr, 24hrs & 48hrs from their collection, when measured from the glass vials and the clot-activated vacutainers respectively, by the Vitros 4600 dry chemistry analyzer. Summary StatementSerum Lithium estimation in clincal laboratory may be done different methodologies, but the result may vary due to change in principle of investigation and the pre analytical and analytical interferences.
Matching journals
The top 4 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Optimization Of Dried Blood Spot Assays For Hepatitis B Virus Surface Antibody Quantification 95%
- EDTA tubes are suitable for insulin and C-peptide measurement in resource-limited settings and can be stored at room temperature for up to 24 hours 94%
- The effects of L-carnitine and fructose in improved Ham's F10 on sperm culture in idiopathic severe asthenospermia within 24h 94%
Similar papers in this journal
- Analysis of serum trace elements, macro-minerals, antioxidants, malondialdehyde and immunoglobulins in seborrheic dermatitis patients: A case-control investigation 95%
- Enzyme Kinetics and Inhibition parameters of Human Leukocyte Glucosylceramidase 93%
- Heavy Metals Induced Health Risk Assessment Through Consumption of Selected Commercially Available Spices in Noakhali District of Bangladesh 93%
Similar papers in this journal
- Evaluation of seven different rapid methods for nucleic acid detection of SARS-COV-2 virus 94%
- Probable causes and risk factors for positive SARS-CoV-2 test in recovered patients: Evidence from Brunei Darussalam 92%
- COVID-19 Sniffer Dog experimental training: which protocol and which implications for reliable identification? 91%
Similar papers in this journal
- Seroprevalence of SARS-CoV-2 in Niger State: A Pilot Cross Sectional Study 91%
- In-silico development of a method for the selection of optimal enzymes using L-asparaginase II against Acute Lymphoblastic Leukemia as an example. 90%
- Impact on Mental Health of students due to restriction caused by COVID-19 pandemic: Cross-sectional study 90%
Similar papers in this journal
- Measuring Repositioning in Home Care for Pressure Injury Prevention and Management 90%
- On the prediction of arginine glycation using artificial neural networks 89%
- CellCountCV - a web-application for accurate cell counting and automated batch processing of microscopy images using fully-convolutional neural networks 89%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.