A Comparative Study Between Nasopharyngeal/Oropharyngeal, Faecal and Saliva Viral Shedding In Ghanaian COVID-19 Patients attending KATH from October-December, 2020

Badu-Boateng, E.; Asante, L. S.; Dompreh, A.; Wihibeturo, L. A. B.; Asante, K. A.; Karikari, S.; Adubofour, A.; Oppong, C.; Acheampong, F.

2021-09-14 public and global health
10.1101/2021.09.04.21262932 medRxiv
Show abstract

BackgroundDiagnostic testing for the current SARS-CoV-2 infections involves the collection and testing of invasive pharyngeal specimens by qualified Health workers. Though fully clad in personal protective equipment, the concern is that sampling in close proximity to the patient poses as a major health hazard. The present study sought to verify if saliva or faeces could become a possible surrogate for pharyngeal samples for SARS-CoV 2 testing in suspected Ghanaian COVID-19 patients. ObjectivesTo ascertain if there is SARS-CoV 2 viral shedding in the saliva and faecal samples of Ghanaian COVID-19 patients, their sensitivity and specificity as compared to pharyngeal samples. MethodFifty (50) recruited COVID-19 patients who have been confirmed via RT-PCR using their nasopharyngeal/oropharyngeal samples and twenty (20) SARS-CoV 2 negative suspected patients each provided some faecal and saliva sample for RT-PCR analysis for SARS-CoV 2. ResultsForty-three (43) out of the fifty (50) COVID-19 patients recruited representing 86% tested positive for SARS-CoV 2 via their saliva sample whiles all their faecal samples tested positive for SARS-CoV 2 representing 100%. The sensitivity of saliva samples was 86% whiles the specificity was 100% but the sensitivity and specificity of the faecal samples were all 100%. ConclusionThere is indeed viral shedding of SARS-CoV 2 in the saliva and faeces of Ghanaian COVID-19 patients just like their counterparts in other parts of the world. Saliva and faeces could possibly become an alternative sample to the current in place of the invasive pharyngeal samples for SARS-CoV 2 testing in resource limited settings. Further research to explore this possibility at different testing sites with larger sample size is recommended.

Matching journals

The top 8 journals account for 50% of the predicted probability mass.

50% of probability mass above

"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.