Journal of Biomedical Optics
● SPIE-Intl Soc Optical Eng
All preprints, ranked by how well they match Journal of Biomedical Optics's content profile, based on 28 papers previously published here. The average preprint has a 0.02% match score for this journal, so anything above that is already an above-average fit. Older preprints may already have been published elsewhere.
Zanoletti, M.; Yaqub, M. A.; Cortese, L.; Buttafava, M.; Martinez Garcia, J.; Amendola, C.; Carteano, T.; Frabasile, L.; Sanoja Garcia, D.; Guadagno, C. N.; Houtbeckers, T.; Karadeniz, U.; Lacerenza, M.; Pagliazzi, M.; Parsa, S.; Wagenaar, T.; Demarteau, L.; Tomanik, J.; Tosi, A.; Weigel, U. M.; Konugolu Venkata Sekar, S.; Torricelli, A.; Contini, D.; Mesquida, J.; Durduran, T.
Show abstract
SignificanceA new platform/device is presented that advances hybrid diffuse optical monitors closed to clinical practice, bridging the gap between research-grade optical systems and practical bedside applications. Traditional devices often lack automation, multi-parameter functionality, and operator independence, hence, limiting their usability in demanding clinical environments. By offering automation, user-friendly operation, and overcoming the typical limitations of continuous-wave near-infrared spectroscopy, the hybrid diffuse optical platform (hDOS) provides a more accurate and reliable assessment of both oxygenation and perfusion. This innovation is particularly valuable for monitoring critically ill patients, where precise real-time measurements can directly influence patient management and outcomes. AimTo design, validate, and characterize the platform hDOS that integrates time-domain near-infrared spectroscopy, diffuse correlation spectroscopy, and a pulse oximeter with an automated vascular occlusion test (VOT). The platform aims to support continuous monitoring and the assessment of peripheral microvascular, and metabolic functions in both clinical and field settings. ApproachThe validation strategy for the hDOS device follows a comprehensive approach that goes beyond conventional optical performance assessments. Rather than solely verifying fundamental system parameters, the evaluation comprises of real-world usability, operator and patient safety, and clinical implementation. The devices precision and usability were rigorously tested in vivo through test-retest measurements and comparisons with a commercially available device (INVOS 5100C). This was subsequently followed by a seven-month clinical evaluation at Parc Tauli Hospital Universitari. ResultsThe device underwent extensive validation, accumulating over 200 hours of usage across approximately 150 measurement sessions. The hDOS device exhibited two-fold lower inter-subject and intra-subject variability in baseline tissue oxygen saturation compared to the INVOS 5100C. Furthermore, during a a vascular occlusion challenge, statistically significant differences were observed between the two systems across all extracted parameters. Finally, as a proof of concept, hDOS successfully detected differences in the microvasculature between a general mixed ICU patient cohort (n = 100) and a healthy control group (n = 37). ConclusionsOverall, hDOS device has performed well in both bench-top and realistic clinical applications on patients in vivo. hDOS device provides a unique combination of parameters, available for the first time in a fully automated, self-contained platform.
Watt, M. J.; Malouf, L.; Tao, R.; Racicot, I.; Else, T. R.; Groehl, J.; Bohndiek, S. E.
Show abstract
Short-wave infrared (SWIR) sensors promise to expand the capabilities of optical sensing technologies but the lack of robust data characterising tissue-constituent optical properties in the SWIR makes instrument design challenging. We characterise and evaluate the optical properties of the dominant chromophores in tissue and tissue-mimicking phantoms, from visible to SWIR wavelengths. Using single-integrating sphere systems, we measured the optical properties of single-component chromophores (H2O, haemoglobin, corn oil, synthetic melanin) and multi-component tissues (whole blood, lard), to decouple contributions from optical scattering, H2O absorption and other contributing chromophores; we also characterised commonly-used phantom materials and investigated their potential to mimic soft tissues in the SWIR range using simulations. We provide a consistent dataset of absorption and reduced scattering coefficients that characterise the dominant tissue chromophores from 450 nm out to 1600 nm. These results were shown to be consistent with literature data, where available. We integrate these data into an open-source Python toolkit, SIMPA, for optical modelling and demonstrate soft tissue simulations that can be probed continuously from visible to SWIR wavelengths. Our findings are compared with tissue-mimicking phantoms, highlighting a need for additives for polymer-based phantoms that mimic SWIR water absorption. By providing this open-source dataset, we aim to enable future studies exploring SWIR light-tissue interactions that facilitate rapid assessment and prototyping of next-generation spectroscopy and imaging techniques.
Lacerenza, M.; Amendola, C.; Bargigia, I.; Bossi, A.; Buttafava, M.; Calcaterra, V.; Contini, D.; Damagatla, V.; Negretti, F.; Rossi, V.; Spinelli, L.; Zanelli, S.; Zuccotti, G.; Torricelli, A.
Show abstract
Recently, skin pigmentation has been shown to affect the performance of pulse oximeters and other light-based techniques like photoacoustic imaging, tissue oximetry, and continuous wave near infrared spectroscopy. Evaluating the robustness to changes in skin pigmentation is therefore essential for the proper use of optical technologies in the clinical scenario. We conducted systematic time domain near infrared spectroscopy measurements on calibrated tissue phantoms and in vivo on volunteers during static and dynamic (i.e., arterial occlusion) measurements. To simulate varying melanosome volume fractions in the skin, we inserted, between the target sample and the measurement probe, thin tissue phantoms made of silicone and nigrosine (skin phantoms). Additionally, we conducted an extensive measurement campaign on a large cohort of pediatric subjects, covering the full spectrum of skin pigmentation. Our findings consistently demonstrate that skin pigmentation has a negligible effect on time domain near infrared spectroscopy results, underscoring the reliability and potential of this emerging technology in diverse clinical settings.
Park, S. M.; McMorrow, S. R.; George, T. G.; Sobolewski, C. M.; Yang, D.; Speh, E.; Daniels-Day, E.; Segel, A.; King, K. T.; Kenley, J.; Smyser, C. D.; Culver, J. P.; Guilliams, K. P.; Eggebrecht, A. T.; Said, A. S.
Show abstract
Extracorporeal membrane oxygenation (ECMO) provides life support for severe, reversible cardiac or respiratory failure but carries substantial risk of neurological complications. Pediatric ECMO patients are particularly vulnerable, with over half of survivors exhibiting abnormal neuroimaging findings following discharge. Currently available clinical neuroimaging tools are limited, offering either static anatomical snapshots (ultrasound, computed tomography) or sparse functional monitoring (electroencephalography, functional near infrared spectroscopy) with limited spatial specificity. High-density diffuse optical tomography (HD-DOT) addresses these limitations to provide noninvasive, longitudinal, wide-field measurements of changes in cortical oxygenation at the beside. Here, we investigate safety and feasibility for bedside longitudinal HD-DOT monitoring of cerebral oxygenation focusing on data collected over 20 days in seven pediatric ECMO patients. Results confirm the reliable acquisition of high-quality HD-DOT data without adverse events, establishing HD-DOT as a promising tool for continuous, and safe bedside neuroimaging in this population.
Reiser, M.; Breidenassel, A.; Amft, O.
Show abstract
We investigate the effects of skin pigmentation and light source characteristics on the performance of reflective Pulse oximetry (PO) devices used in healthcare and well-being applications. We use Monte Carlo (MC) simulations to compare ideal monochromatic and realistic LED spectral emission profiles and tolerance-related wavelength shifts. The simulation covers photon transport in skin models with melanin concentrations (2.55% to 30.5%) and arterial oxygen saturations SaO2 (70% to 100%.) Accuracy was assessed by SpO2 error, root-mean-square error RMSE (Arms), and percentile tail-errors (P90, P95, and P99). Monochromatic spectral emission yielded the lowest SpO2 error (RMSE = 1.32), while LED spectral emission profiles increased errors (RMSE = 2.10). Infrared wavelength tolerances increased SpO2 RMSE by 1.1 {+/-} 0.3. SpO2 error increased with melanin concentration, from underestimation (-1.8 {+/-} 0.1%) at 2.55% melanin concentration to overestimation (+3.9 {+/-} 1.2%) at 30.5% for low SaO2 (70%) and LED spectral emission profiles. At 30.5% melanin concentration, P95 and P99 exceeded FDA and DIN EN ISO 80601-2-61 thresholds, in particular at low SaO2 (70%). Clipping SpO2 estimates at 100% resulted in an apparent RMSE decrease of up to 3%, reflecting error masking rather than real error reduction. In conclusion, LED spectral emission profiles and wavelength tolerances can amplify melanin-related bias in SpO2 estimates. Monochromatic emission and tighter wavelength control can reduce SpO2 error and should be considered in device design and regulation. Regulatory standards should discourage clipping SpO2 estimates at 100% and mandate additional metrics as RMSE fails to reflect clinically critical percentile error thresholds, i.e. P95 and P99.
Gong, A. T.; Dulal, A.; Crane, M. M.; Reihsen, T.; Sweet, R. M.; Mendenhall, A. R.
Show abstract
Our research is focused on creating and simulating hyper-realistic artificial human tissue analogues. Generation and simulation of macroscopic biological material depends upon accurate ground-truth data on spectral properties of materials. Here, we developed methods for high fidelity spectral data collection using two differently colored simulated skin tissue samples and a portable spectral imaging camera. Using the standard procedure, we developed, we quantified the reproducibility of the spectral image signatures of the two synthetic skin samples under natural and artificial lighting conditions commonly found in clinical settings. We found high coefficients of determination for all measures taken under the same lighting. As expected, we found the spectral image signature of each sample was dependent on the illumination source. Our results confirm that illumination spectra data should be included with spectral image data. The high-fidelity methods for spectral image data collection we developed here should facilitate accurate collection of spectral image signature data for gross biological samples and synthetic materials collected under the same illumination source.
Kluiszo, E.; Belcatsro, L.; Ahmmed, R.; Sunar, U.
Show abstract
Accurate knowledge of tissue absorption (a) and reduced scattering [Formula] parameters are required to plan and monitor laparoscopic chemophototherapy (CPT) in ovarian cancer, including light dosimetry and quantitative fluorescence mapping of porphyrin-phospholipid (PoP) photobleaching and light-triggered doxorubicin (Dox) release. We implemented a depth-sensitive, multi-frequency laparoscopic spatial frequency domain imaging (SFDI) framework to improve optical-property estimation in layered tissue. A DMD-based laparoscope imaged two-layer phantoms with controlled optical contrasts and superficial thicknesses. Spatial-frequency subsets associated with different penetration depths were independently fit to recover a and [Formula], and compared with a two-layer diffusion model. Recovered [Formula] values remained bounded by the known layer references and shifted monotonically toward the superficial value as spatial frequency and top-layer thickness increased, approaching a single-layer response at high frequency/thick layers. Quantitative model comparison showed {delta}-P1 variants outperformed the standard diffusion approximation, reducing RMSPE between modeled and measured [Formula] to 0.8-6.5% (silicone/silicone) and 1.6-8.3% (silicone/intralipid), whereas SDA errors reached [~]13.8% and 21.1%, respectively. This approach demonstrates multi-frequency laparoscopic SFDI as a practical initial step for depth-sensitive fluorescence correction for individualized CPT treatment planning and monitoring.
Rasouli, R.; Hartl, B.; Konecky, S. D.
Show abstract
Circulating microclots are increasingly linked to long COVID as well as its persistent symptoms such as fatigue, cognitive deficits, and cardiovascular complications. These conditions can become debilitating or even life-threatening, which create an urgent need for rapid and reliable detection and monitoring tools. In this study we investigate pulsed speckle contrast optical spectroscopy (p-SCOS) as a non-invasive and label-free method to detect microclots in biofluids. Microclots at four concentrations (21k, 91k, 400k, and 1.7M microclots/mL), representing levels from healthy individuals to acute coagulopathic states, were generated using a freeze-thaw method. We measured speckle contrast under flowing conditions in a custom-made flow phantom. In phosphate-buffered saline (PBS) and plasma, increasing microclot concentration consistently led to measurable decreases in speckle contrast. The measurement differentiated between low and high clot burdens in transparent media which highlights its potential for microclot monitoring. In comparison, no detectable changes were observed in whole blood, likely due to dominant scattering from red blood cells masking microclot effects. Overall, our findings demonstrate the feasibility of p-SCOS as a rapid and label-free tool for microclot detection and monitoring in transparent biofluids.
Ahmmed, R.; Kluiszo, E.; Aygun-Sunar, S.; Willadsen, M.; Kutscher, H. L.; Lovell, J.; Sunar, U.
Show abstract
Chemophototherapy (CPT) is an emerging cancer treatment that leverages the synergistic effects of photodynamic therapy (PDT) and chemotherapy. This approach utilizes photosensitizers like Porphyrin Phospholipid (PoP) and Doxorubicin (Dox) to enable phototriggered drug release and targeted tumor destruction. In this study, we present the development and validation of a wide-field laparoscopic spatial frequency domain imaging (SFDI) system, designed to improve intraoperative quantitative fluorescence imaging and monitoring of PoP photobleaching, a PDT-driven effect for tumor destruction, and light-activated Dox release, which facilitates targeted chemotherapeutic drug delivery in an ovarian cancer model. Compared to previous flexible endoscopic imaging methods, our laparoscopic SFDI system offers enhanced spatial coverage, enabling accurate wide-field optical property quantification in minimally invasive surgical settings. Using this system, we performed quantitative fluorescence imaging in vivo to obtain absolute concentrations of PoP and Dox fluorescence, correcting for tissue absorption and scattering effects. This capability allows for precise assessment of PoP photobleaching and Dox release kinetics with improved spatial resolution. Fluorescence imaging revealed a significant reduction in PoP concentration in tumor regions post-illumination, demonstrating the PDT-mediated photobleaching effect and successful light-triggered drug release activation for chemo-induced tumor destruction. The ability to differentiate PoP and Dox fluorescence in a laparoscopic system underscores its potential for real-time intraoperative monitoring of CPT efficacy. These findings establish wide-field laparoscopic SFDI as a promising tool for guiding minimally invasive photodynamic therapy and targeted drug delivery in clinical settings.
Campbell, C. A.; Kennedy, G. T.; Martin-Perez, A.; Chin, T. L.; Joe, V.; Christy, R. J.; Durkin, A. J.
Show abstract
Spatial frequency domain imaging (SFDI) has demonstrated the ability to provide early, quantitative assessment of burn wound severity. Previous studies using a research-grade SFDI platform showed that high-dimensional datasets incorporating multiple spatial frequencies and wavelengths can predict healing outcomes in controlled porcine models of graded burns. To assess the impact of reduced measurement dimensionality on diagnostic performance, we compared classifications derived from a research-grade SFDI system (Reflect RS) with those obtained using a simplified commercial SFDI platform (Clarifi RS). Both systems were used to image graded burns 24 hours after injury. Pixel-level classifiers were trained using regions defined by 28-day healing outcomes, and models based on the full Reflect dataset were compared with classifiers generated from reduced Reflect feature sets and datasets designed to mimic Clarifi acquisition features. Performance was evaluated using leave-one-subject-out validation. The full Reflect dataset achieved the highest classification performance, with mean F1 scores approaching 0.88. Although reducing the number of measured features decreased classification accuracy, simplified models and Clarifi-based datasets maintained F1 scores greater than 0.8 for binary classification. These findings indicate that dimensionality reduction produces a measurable but manageable loss in performance and support the development of clinically practical, application-specific SFDI systems for burn assessment.
Yuan, N.; Ragab, S.; Nizam, N. I.; Pandey, V.; Verma, A.; Young, T.; Williams, J. C.; Barroso, M.; Intes, X.
Show abstract
SignificanceMacroscopic Fluorescence Lifetime Imaging (MFLI) is a powerful, non-invasive imaging modality that offers robust, physiologically relevant contrast largely independent of fluorophore concentration, excitation intensity, and tissue signal attenuation. However, accurately determining the depth of signal origin remains challenging, potentially leading to ambiguity in biological interpretation. Here, we present a novel optical correction method that effectively eliminates surface signal bias, such as that from skin in preclinical imaging, without the need for chemical clearance. This advancement supports the robust applicability of MFLI in translational research. AimEstablishment of a High Spatial Frequency-Fluorescence Lifetime Imaging (HSF-FLI) framework to selectively isolate subsurface fluorescence (deeper signals) from surface fluorescence, while preserving the accuracy of lifetime estimation. ApproachA modulation transfer function (MTF) that relates spatial frequency to penetration depth was derived using Monte Carlo eXtreme (MCX) simulations (for physics-based modeling) and validated with agar-based capillary phantoms on a time-gated ICCD-DMD system. Depth-independent fluorescence was decomposed into surface and subsurface components through structured three-phase sinusoidal illumination, and nonlinear least squares fitting was applied to recover lifetime or lifetime based parameters maps. HSF-FLI was demonstrated in vivo in mouse models bearing tumor xenogratfs and was cross validated with ex vivo measurements. ResultsWe extensively characterized the performance of High Spatial Frequency-Fluorescence Lifetime Imaging (HSF-FLI) through simulations and tissue-mimicking phantoms. The approach was further validated in vivo by assessing drug delivery in preclinical models using MFLI-FRET (Forster Resonance Energy Transfer). ConclusionBy coupling structured illumination with physics-based depth modeling, HSF-FLI delivers accurate, depth-selective lifetime readouts, setting the stage for robust and fast FLI implementation in translational studies.
Yang, B.; Miller, W.
Show abstract
Tissue perfusion properties reveal crucial information pertinent to clinical diagnosis and treatment. Multispectral spatial frequency domain imaging (SFDI) is an emerging imaging technique that has been widely used to quantify tissue perfusion properties. However, slow processing speed limits its usefulness in real-time imaging applications. In this study, we present a two-stage look-up table (LUT) approach that accurately and rapidly quantifies optical (absorption and reduced scattering maps) and perfusion (total hemoglobin and oxygen saturation maps) properties using stage-1 and stage-2 LUTs, respectively, based on reflectance images at 660nm and 850nm. The two-stage LUT can be implemented on both CPU and GPU computing platforms. Quantifying tissue perfusion properties using the simulated diffuse reflectance images, we achieved a quantification speed of 266, 174, and 74 frames per second for three image sizes 512x512, 1024x1024, and 2048x2048 pixels, respectively. Quantification of tissue perfusion properties was highly accurate with only 3.5% and 2.5% error for total hemoglobin and oxygen saturation quantification, respectively. The two-stage LUT has the potential to be adopted in existing SFDI applications to enable real-time imaging capability of tissue hemodynamics.
Sawyer, T. W.; Knapp, T. G.
Show abstract
Duodenal gastrinomas (DGASTs) are neuroendocrine tumors that develop in the submucosa of the duodenum and produce the hormone gastrin. Surgical resection of DGASTs is complicated by the small size of these tumors and the tendency for them to develop diffusely in the duodenum. Endoscopic mucosal resection of DGASTS is an increasingly popular method for treating this disease due to its low complication rate but suffers from poor rates of pathologically negative margins. Multiphoton microscopy (MPM) is capable of capturing high-resolution images of biological tissue with contrast generated from endogenous fluorescence (autofluorescence) through two-photon excited fluorescence (2PEF). Second harmonic generation (SHG) is another popular method of generating image contrast with MPM and is a light-scattering phenomenon that occurs predominantly from structures such as collagen in biological samples. Some molecules that contribute to autofluorescence change in abundance from processes related to the cancer disease process (e.g., metabolic changes, oxidative stress, angiogenesis). MPM was used to image 12 separate patient samples of formalin-fixed and paraffinized DGAST slides with a SHG channel 4 2PEF channels, each tuned to capture fluorescence from NADH, FAD, lipofuscin, and porphyrin. We found that there was a significant difference in the relative abundance of signal generated in the 2PEF in comparison to the neighboring tissues of the duodenum. Texture extraction was used to create linear discriminant classifiers for tumor vs all other tissue classes before and after principal component analysis (PCA) of the texture feature dataset. PCA improved the classifier accuracy and reduced the number of features required to achieve maximum accuracy of the classifier. The LDA classifier after PCA distinguished between tumor and other tissue types with an accuracy of 90.6 - 93.8%. These results suggest that MPM 2PEF and SHG imaging is a promising label-free method for discriminating between DGAST tumors and normal duodenal tissue which has implications for future applications of in vivo assessment of resection margins with endoscopic MPM.
Islam, I. S.; Rajput, J. S.; Albarran, K.; Enam, S. F.; Barwari, M.; Dobariya, A.; Patel, A.; Dunbar, M.; Pascual, J.; Hoffmann, U.; Patnaik, S.
Show abstract
BackgroundOptical Coherence Tomography Angiography (OCTA) provides high-resolution visualization of retinal microvasculature, with vascular density (VD) serving as a one of the key quantitative metrics. However, VD measurements are highly sensitive to image binarization step, and no standardized approach exists. MethodsWe analyzed 51 OCTA scans (human and porcine) using 29 binarization algorithms, including global and local thresholding techniques from ImageJ and DoxaPy, as well as Random Walker segmentation. VD was calculated for each binarization algorithm and compared against Optovue-generated values (ground truth). Results were evaluated using hierarchical clustering and agreement between them was determined by Bland-Altman analysis. ResultsWolf algorithm was found to exhibit least deviation from mean Optovue VD values for human SCP layer (46.5 {+/-} 1.2% vs. 48.3 {+/-} 1.4%; p = 3.62 x 10-5); however, there is not significant difference between VDs from Optovue and Wolf algorithms from porcine SCP layer (46.2 {+/-} 1.8 % vs 46.3 {+/-} 1.4% ; p=0.74). For DCP layer, Phansalkar algorithm exhibited least VD variability (50.7 {+/-} 2.0% vs. 51.9 {+/-} 1.7%; p=2.53 x 10-4) in the human cohort. Whereas Percentile algorithm exhibited least, non-significant variations in the porcine DCP layer VD (50.0 {+/-} 1.4 % vs. 50.3 {+/-} 1.4%; p=0.75). DiscussionEach binarization technique evaluated in this study impacts OCTA-derived VD measurements differently. Local adaptive algorithms collectively outperform global methods, particularly for SCP analysis. Standardization of image processing pipelines and layer-specific optimization are essential to improve reproducibility and clinical consistency.
Ankri, R.; Harel, M.; Arbiv, U.
Show abstract
Fluorescence lifetime imaging has an enormous impact on our understanding of biological systems, both in vitro and in vivo. It is a powerful tool for the non-invasive in vitro and in vivo biomolecular and cellular investigations. In particular, it has the potential to target and multiplex different species with high sensitivity and specificity, providing a fast and noninvasive readout at low cost. In this work, we present a time-saving Monte Carlo (MC) simulation of fluorescent photons scattering within a turbid medium, followed by phasor analyzes which enabled the simple multiplexing of different targets in one frame. We then demonstrate a simple and fast method for wide-field FLI in the near-infrared (NIR) region, where tissue scattering and autofluorescence are significantly lower, to enable imaging of deep tissue, using the state-of-the-art timed single-photon avalanche diode array camera (SPAD), SPAD512S. In particular, we show how phasor scattering increases with depth. However, using appropriate background correction, a simple "cut-off" method, and averaging, we can multiplex two targets in one image to a depth of 1 cm in tissue. Our results show that it is possible to perform in vivo FLI under challenging conditions, using standard NIR fluorophores with short lifetimes.
Langley, A.; Sweeney, A.; Shethia, R. T.; Bednarke, B.; Wulandana, F.; Xavierselvan, M.; Mallidi, S.
Show abstract
Understanding the tumor microenvironment, particularly the vascular density and the availability of oxygen, is key in individualizing treatment approaches and determining their efficacy. While there are many therapies including radiotherapy that are ineffective in hypoxic tumor microenvironments, here we demonstrate the heterogeneous oxygen consumption during photodynamic therapy (PDT), a non-invasive treatment method using localized light to activate a photosensitive drug in the presence of oxygen that has shown high effectiveness in the treatment of various types of tumors, including those presented in head and neck cancer (HNC) patients. While our previous work has demonstrated that blood oxygen saturation (StO2) mapped before and after treatment with ultrasound-guided photoacoustic imaging (US-PAI) can be used as a surrogate marker for the regionalized long-term efficacy of PDT, real-time monitoring of StO2 during PDT could provide additional insights on oxygen consumption and inform dose design for "on the spot" treatment decisions. Specifically, in this work, we integrated the US-PAI transducer probe with PDT light delivery fibers. We tested the setup on murine tumor models intravenously injected with liposomal benzoporphyrin derivative (BPD) photosensitizer at 0.5 mg/kg dose and photodynamic illumination at 100 and 400 mW/cm2 fluence rate. As expected, we observed with our US-PAI StO2 images that the rate of oxygen utilization increases when using a high fluence rate (HFR) light dose. Particularly in the higher fluence rate group, we observed StO2 reaching a minimum mid-light dose, followed by some degree of re-oxygenation. US-PAI added the advantage of spatial information to StO2 monitoring, which allowed us to match regions of re-oxygenation during therapy to retained vascular function with immunohistochemistry. Overall, our results have demonstrated the potential of US-PAI for applications in online dosimetry for cancer therapies such as PDT, using oxygen changes to detect regionalized physiological vascular response in the tumor microenvironment.
Vicente, J. R.; Durkin, A.; Shrestha, K.; Balu, M.
Show abstract
Melanin plays a significant role in the regulation of epidermal homeostasis and photoprotection of human skin. The assessment of its epidermal distribution and overall content is of great interest due to its involvement in a wide range of physiological and pathological skin processes. Among several spectroscopic and optical imaging methods that have been reported for non-invasive quantification of melanin in human skin, the approach based on the detection of two-photon excited fluorescence lifetime distinguishes itself by enabling selective detection of melanin with sub-cellular resolution, thus facilitating its quantification while also resolving its depth-profile. A key limitation of prior studies on the melanin assessment based on this approach is their inability to account for the skin heterogeneity due to the reduced field of view of the images, which results in high dispersion of the measurement values. Pigmentation in both normal and pathological human skin is highly heterogeneous and its macroscopic quantification is critical for reliable measurements of the epidermal melanin distribution and for capturing melanin-related sensitive dynamic changes as a response to treatment. In this work, we employ a fast large-area multiphoton exoscope (FLAME), recently developed by our group for clinical skin imaging, that has the ability to evaluate the 3D distribution of epidermal melanin content in vivo macroscopically (millimeter scale) with microscopic resolution (sub-micron) and rapid acquisition rates (minutes). We demonstrate significant enhancement in the reliability of the melanin density and distribution measurements across Fitzpatrick skin types I to V by capturing the intra-subject pigmentation heterogeneity enabled by the large volumetric sampling. We also demonstrate the potential of this approach to provide consistent measurement results when imaging the same skin area at different times. These advances are critical for clinical and research applications related to monitoring pigment modulation as a response to therapies against pigmentary skin disorders, skin aging, as well as skin cancers.
Daigle, N.; Knapp, T.; Duan, S.; Jones, D. W.; Azhdarinia, A.; Ghosh, S. C.; AghaAmiri, S.; Ikoma, N.; Estrella, J. S.; Schnermann, M. J.; Merchant, J. L.; Sawyer, T. W.
Show abstract
Pancreatic neuroendocrine tumors (PNETs) are a rare but increasingly more prevalent cancer with heterogeneous clinical and pathological presentation. Surgery is the preferred treatment for all hormone-expressing PNETs and any PNET greater than 2 cm, but difficulties arise when tumors are multifocal, metastatic, or small in size due to lack of effective surgical localization. Existing techniques such as intraoperative ultrasound provide poor contrast and resolution, resulting in low sensitivity for such tumors. Somatostatin receptor type 2 (SSTR2) is commonly overexpressed in PNETs and presents an avenue for targeted tumor localization. SSTR2 is often used for pre-operative imaging and therapeutic treatment, with recent studies demonstrating that somatostatin receptor imaging (SRI) can be applied in radioguided surgery to aid in removal of metastatic lymph nodes and achieving negative surgical margins. However not all PNETs express SSTR2, indicating labeled SRI could benefit from using a supplemental label-free technique such as multiphoton microscopy (MPM), which has proven useful in improving the accuracy of diagnosing more common exocrine pancreatic cancers. Our work tests the suitability of combined SRI and MPM for localizing PNETs by imaging and comparing samples of PNETs and normal pancreatic tissue. Specimens were labeled with a novel SSTR2-targeted contrast agent and imaged using fluorescence microscopy, and subsequently imaged using MPM to collect four autofluo-rescent channels and second harmonic generation. Our results show that a combination of both SRI and MPM provides enhanced contrast and sensitivity for localizing diseased tissue, suggesting that this approach could be a valuable clinical tool for surgical localization and treatment of PNETs.
Patel, A.; Zhong, X.; Moffett, M. A.; Sun, Y.; Dennis, A. M.
Show abstract
SignificanceWhile shortwave infrared (SWIR) imaging provides superior tissue penetration and reduced autofluorescence for preclinical applications, quantitative fluorescence analysis is hindered by the limited dynamic range of InGaAs cameras, forcing a focus on either bright or dim anatomical features. AimWe develop a high dynamic range (HDR) imaging method specifically adapted for the high-noise characteristics of InGaAs detectors to enable quantitative fluorescence imaging across wide intensity ranges. We demonstrate that one-time camera calibration based on a series of images encompassing the range of radiance intensities enables all subsequent image processing. ApproachWe modified classical HDR algorithms with exposure-time-dependent dark current subtraction, preprocessing to exclude saturated and noisy pixels before camera response function recovery, and dynamic weighting range adjustment to account for shrinking intensity ranges at longer exposures. HDR image processing effects on preclinical imaging outcomes were analyzed using indocyanine green and SWIR-emitting PbS/CdS quantum dots in mouse models. ResultsHDR imaging achieved a 22 dB improvement in dynamic range over single exposures, enabling simultaneous quantification across more than three orders of magnitude of fluorophore concentration. In vivo studies showed improvements in contrast-to-noise ratios across all anatomical features, with improvements in vascular contrast while maintaining quantitative accuracy. After one-time camera calibrations, this approach enables rapid processing of subsequent datasets. ConclusionsThis software-based HDR SWIR imaging approach eliminates exposure parameter optimization and enables comprehensive biodistribution analysis across all anatomical structures from a single acquisition sequence, significantly streamlining preclinical imaging workflows while preserving quantitative accuracy.
Fernandes, M.; Huang, Y. X.; Xu, I.; Noguera Saigua, C.; Li, J.; Mahler, S.
Show abstract
Cerebral blood volume (CBV) and blood flow (CBF) constitute key metrics for cerebrovascular monitoring, enabling assessment of stroke severity and risk-prediction, aging-related changes, and neurological diseases. CBF and CBV monitoring are key aspects in diagnosis, treatment triage, and clinical outcome of ischemic and hemorrhagic strokes. In recent years, there have been ongoing efforts toward the development of optical devices for noninvasive monitoring of CBV and CBF. Speckle contrast optical spectroscopy (SCOS) has recently emerged as a strong candidate for clinical translation in monitoring CBF and CBV, due to its affordability, compact and wearable design, and noninvasive nature. However, experimental demonstrations that SCOS can effectively monitor brain hemodynamics remain sparse. This is primarily due to challenges in design experiments that isolate cerebral blood dynamics from those in the scalp and skull. In this paper, we report experiments using SCOS to monitor cerebral hemodynamics in rats during intracerebral blood flow modulation. To modify cerebral blood dynamics, a surgical procedure was performed to insert a catheter for direct injection of flow modulation fluids into the brain. Using the SCOS device, we monitored changes in CBV during deliberate CBF interventions into the brains of five rats. A saline solution was also injected as a sham control of the flow intervention. The results show a significant decrease in CBV during injection, followed by a return to baseline. This behavior is consistent with physiological expectations, as the injected fluids dilute the blood, leading to a transient reduction in blood volume. Notably, the CBV decrease induced by the flow modulation fluid solution required more than twice as long to recover to baseline compared with the saline solution, which is consistent with the delayed clearance of the flow modulation fluid by design. These experimental results demonstrate the effectiveness of SCOS for monitoring cerebral hemodynamics in animal models and highlight its potential for translation to human studies. Moreover, this work paves the way for the testing and characterization of cerebral therapeutic agents intended for blood flow modulation in animal models.