"hDOS": An automated hybrid diffuse optical device for real-time non-invasive tissue monitoring - precision and in vivo validation.
Zanoletti, M.; Yaqub, M. A.; Cortese, L.; Buttafava, M.; Martinez Garcia, J.; Amendola, C.; Carteano, T.; Frabasile, L.; Sanoja Garcia, D.; Guadagno, C. N.; Houtbeckers, T.; Karadeniz, U.; Lacerenza, M.; Pagliazzi, M.; Parsa, S.; Wagenaar, T.; Demarteau, L.; Tomanik, J.; Tosi, A.; Weigel, U. M.; Konugolu Venkata Sekar, S.; Torricelli, A.; Contini, D.; Mesquida, J.; Durduran, T.
Show abstract
SignificanceA new platform/device is presented that advances hybrid diffuse optical monitors closed to clinical practice, bridging the gap between research-grade optical systems and practical bedside applications. Traditional devices often lack automation, multi-parameter functionality, and operator independence, hence, limiting their usability in demanding clinical environments. By offering automation, user-friendly operation, and overcoming the typical limitations of continuous-wave near-infrared spectroscopy, the hybrid diffuse optical platform (hDOS) provides a more accurate and reliable assessment of both oxygenation and perfusion. This innovation is particularly valuable for monitoring critically ill patients, where precise real-time measurements can directly influence patient management and outcomes. AimTo design, validate, and characterize the platform hDOS that integrates time-domain near-infrared spectroscopy, diffuse correlation spectroscopy, and a pulse oximeter with an automated vascular occlusion test (VOT). The platform aims to support continuous monitoring and the assessment of peripheral microvascular, and metabolic functions in both clinical and field settings. ApproachThe validation strategy for the hDOS device follows a comprehensive approach that goes beyond conventional optical performance assessments. Rather than solely verifying fundamental system parameters, the evaluation comprises of real-world usability, operator and patient safety, and clinical implementation. The devices precision and usability were rigorously tested in vivo through test-retest measurements and comparisons with a commercially available device (INVOS 5100C). This was subsequently followed by a seven-month clinical evaluation at Parc Tauli Hospital Universitari. ResultsThe device underwent extensive validation, accumulating over 200 hours of usage across approximately 150 measurement sessions. The hDOS device exhibited two-fold lower inter-subject and intra-subject variability in baseline tissue oxygen saturation compared to the INVOS 5100C. Furthermore, during a a vascular occlusion challenge, statistically significant differences were observed between the two systems across all extracted parameters. Finally, as a proof of concept, hDOS successfully detected differences in the microvasculature between a general mixed ICU patient cohort (n = 100) and a healthy control group (n = 37). ConclusionsOverall, hDOS device has performed well in both bench-top and realistic clinical applications on patients in vivo. hDOS device provides a unique combination of parameters, available for the first time in a fully automated, self-contained platform.
Matching journals
The top 1 journal accounts for 50% of the predicted probability mass.
Similar papers in this journal
- A combined frequency domain near infrared spectroscopy and diffuse correlation spectroscopy system for comprehensive metabolic monitoring of inspiratory muscles during loading 96%
- Targeted spectroscopy in the eye fundus 96%
- Application of Transfer Learning for Rapid Calibration of Spatially-resolved Diffuse Reflectance Probes for Extraction of Tissue Optical Properties 94%
Similar papers in this journal
- A scalable, multi-wavelength, broad bandwidth frequency-domain near-infrared spectroscopy platform for real-time quantitative tissue optical imaging 96%
- Development and evaluation of a wearable peripheral vascular compensation sensor in a swine model of hemorrhage 95%
- First-in-clinical application of a time-gated diffuse correlation spectroscopy system at 1064nm using superconducting nanowire single photon detectors 95%
Similar papers in this journal
- Portable Six-Channel Laser Speckle System for Simultaneous Cerebral Blood Flow and Volume Measurement with Potential Application for Characterization of Brain Injury 96%
- Mid-infrared photoacoustic brain imaging enabled by cascaded gas-filled hollow-core fiber lasers 92%
- Laser speckle contrast imaging for visualizing blood flow during cerebral aneurysm surgery: A comparison with indocyanine green angiography 91%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.