Depth-Resolved Macroscopic Fluorescence Lifetime Imaging via High-Spatial-Frequency Structured Illumination

Yuan, N.; Ragab, S.; Nizam, N. I.; Pandey, V.; Verma, A.; Young, T.; Williams, J. C.; Barroso, M.; Intes, X.

2025-06-15 bioengineering
10.1101/2025.06.10.658928 bioRxiv
Show abstract

SignificanceMacroscopic Fluorescence Lifetime Imaging (MFLI) is a powerful, non-invasive imaging modality that offers robust, physiologically relevant contrast largely independent of fluorophore concentration, excitation intensity, and tissue signal attenuation. However, accurately determining the depth of signal origin remains challenging, potentially leading to ambiguity in biological interpretation. Here, we present a novel optical correction method that effectively eliminates surface signal bias, such as that from skin in preclinical imaging, without the need for chemical clearance. This advancement supports the robust applicability of MFLI in translational research. AimEstablishment of a High Spatial Frequency-Fluorescence Lifetime Imaging (HSF-FLI) framework to selectively isolate subsurface fluorescence (deeper signals) from surface fluorescence, while preserving the accuracy of lifetime estimation. ApproachA modulation transfer function (MTF) that relates spatial frequency to penetration depth was derived using Monte Carlo eXtreme (MCX) simulations (for physics-based modeling) and validated with agar-based capillary phantoms on a time-gated ICCD-DMD system. Depth-independent fluorescence was decomposed into surface and subsurface components through structured three-phase sinusoidal illumination, and nonlinear least squares fitting was applied to recover lifetime or lifetime based parameters maps. HSF-FLI was demonstrated in vivo in mouse models bearing tumor xenogratfs and was cross validated with ex vivo measurements. ResultsWe extensively characterized the performance of High Spatial Frequency-Fluorescence Lifetime Imaging (HSF-FLI) through simulations and tissue-mimicking phantoms. The approach was further validated in vivo by assessing drug delivery in preclinical models using MFLI-FRET (Forster Resonance Energy Transfer). ConclusionBy coupling structured illumination with physics-based depth modeling, HSF-FLI delivers accurate, depth-selective lifetime readouts, setting the stage for robust and fast FLI implementation in translational studies.

Matching journals

The top 2 journals account for 50% of the predicted probability mass.

1
Journal of Biomedical Optics
28 papers in training set
Top 0.1%
45.2%
2
Biomedical Optics Express
95 papers in training set
Top 0.1%
11.8%
50% of probability mass above
3
Photoacoustics
12 papers in training set
Top 0.1%
10.5%
4
Scientific Reports
3612 papers in training set
Top 35%
3.2%
5
ACS Photonics
13 papers in training set
Top 0.1%
2.4%
6
Optica
27 papers in training set
Top 0.2%
2.4%
7
Analytical Chemistry
218 papers in training set
Top 1%
1.9%
8
Neurophotonics
42 papers in training set
Top 0.3%
1.7%
9
Optics Letters
13 papers in training set
Top 0.1%
1.7%
10
ACS Sensors
49 papers in training set
Top 0.6%
1.1%
11
Communications Biology
993 papers in training set
Top 22%
1.1%
12
npj Imaging
12 papers in training set
Top 0.2%
1.1%
13
Light: Science & Applications
16 papers in training set
Top 0.2%
1.1%
14
Science Advances
1243 papers in training set
Top 28%
1.0%
15
Optics Express
26 papers in training set
Top 0.3%
0.8%
16
Advanced Science
286 papers in training set
Top 10%
0.8%
17
Biophysical Journal
631 papers in training set
Top 5%
0.8%
18
International Journal of Molecular Sciences
494 papers in training set
Top 15%
0.8%
19
IEEE Transactions on Medical Imaging
21 papers in training set
Top 0.5%
0.8%
20
European Journal of Nuclear Medicine and Molecular Imaging
20 papers in training set
Top 0.2%
0.6%
21
Bioconjugate Chemistry
20 papers in training set
Top 0.4%
0.6%
22
Nature Communications
5641 papers in training set
Top 60%
0.6%