Back

Design and Test Novel EEG Electrode Attachments for Type 4 Afro-textured Hairstyles

Broor, M.; Ogunniyi, K.; Williamson, L.; Liu, C.

2026-10-08 neuroscience
10.64898/2026.10.01.755885 bioRxiv
Show abstract

Black participants remain underrepresented in electroencephalography (EEG) research, partly because current EEG devices work poorly with dense, coily Type 4 Afro-textured hair. Research-grade EEG typically wires electrodes on a cap, and therefore the electrodes often fail to reach the scalp through dense, Afro-textured hair. Protocols that ask Black participants to unbraid or restyle protective hairstyles add burdens that discourage enrollment in research studies. To address this, we designed and tested 3D-printed attachments that fit onto an EEG electrode and anchored it directly in the hair, using the hairstyle itself as the mounting structure. We fabricated three design configurations for natural Afro-textured hair, cornrows/braids, and twists/microlocs. Seventeen healthy adults with Type 4a-4c hair used electrode attachments that matched their hairstyle. During a single visit, EEG was recorded with 16 conventional cap electrodes defined by the international 10-20 system and with 16 electrodes using novel electrode attachments anchored directly to their hair. Participants completed resting and walking trials with each system. Electrode-to-scalp distance and gel volume were measured during setup. Electrode disconnection, impedance, signal quality (i.e. peak alpha power and aperiodic (1/f) component), and comfort level were measured throughout the data collection. Compared with the conventional cap, the novel attachments reduced electrode-to-scalp distance, gel use, and impedance. Twenty percent of the conventional cap electrodes failed to connect to the scalp compared with 0.1% of novel electrodes. Impedance rose across trials for the conventional cap, whereas the novel attachments showed a smaller increase and maintained lower impedance throughout. Signal quality was significantly better using the novel attachments, while comfort level did not differ between systems. In conclusion, hair-anchored electrode attachment may present a feasible alternative to conventional cap-based EEG for people with Type 4 hair, yielding more usable channels and better signal quality, and supporting more inclusive EEG acquisition.

Matching journals

The top 5 journals account for 50% of the predicted probability mass.

50% of probability mass above

"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.