Back

Systematic review finds keratoconus AI unproven in fellow eyes with normal topography and tomography

Jiang, H.; Gao, F.; Jie, Y.; Yang, L.; Li, Y.; Jiang, Y.

2026-10-02 ophthalmology
10.64898/2026.09.29.26364068 medRxiv
Show abstract

Published artificial intelligence for keratoconus is unproven in fellow eyes that topography and tomography call normal, the eyes where surgical decisions are made, although it reports near-perfect accuracy for early disease. In a registered systematic review of 573 studies (PROSPERO CRD420261441197), none of 2,035 claim-by-stratum units from 212 adjudicated studies established discrimination in these eyes. Most units (90.0%) answered a different question, never constructed the target population or certified its normality; external validation did not test label generation, and five systematic reviews did not assess it. In a public cohort, a frozen score yielded an area under the receiver operating characteristic curve of 0.996 against a same-eye index label and 0.549 against a contralateral proxy; its inputs reconstructed the label-generating index (r = 0.991), so accuracy there measured agreement with the index. Anchor-gap evaluation measures accuracy in these eyes against the contralateral clinical diagnosis.

Matching journals

The top 4 journals account for 50% of the predicted probability mass.

50% of probability mass above