Use of Implantable Loop Recorders: Incidence, Indications for Use, and Pre-implant Rhythm Monitoring Across U.S. Health Systems from 2020-2025
Andersen, M. C.; Ross, J. S.; Ghosh, R.; Correia, L. C. L.; Dhruva, S. S.
Show abstract
Background Implantable loop recorders (ILRs) provide continuous rhythm monitoring. Professional society guidelines and expert consensus statements recommend ILR use for patients with recurrent syncope and cryptogenic stroke, but recommendations are weaker for other indications. We assessed ILR use over time and concordance between indication and clinical guidance. Methods We conducted a retrospective cohort study using Epic Cosmos data from 1/1/2020-12/31/2025. Among active patients with at least one of 13 diagnoses potentially eligible for ILR placement, we identified ILR placements and classified them by concordance with professional society guidance: concordant, possibly, or non-addressed. Annual incidence was estimated overall and by indication. We also described the proportion of patients who received longer-term (>7 days) rhythm monitoring in the year prior to placement. Results Of 47,046,706 patients with diagnoses potentially eligible for ILR placement, 201,103 (0.4%) had an ILR placed. ILR placements increased from 3.08 ILRs per 100,000 patient-days in 2020 to 4.13 in 2025 (5.9% annual growth). The most common indications were cryptogenic stroke (28.6%) and atrial fibrillation without prior ablation (21.4%). Overall, 43.9% were guidance concordant, 28.5% possibly concordant, and 24.8% non-addressed. Relative annual growth in ILR placements per 100,000 patient-days was significant across all guidance categories: concordant (1.3%, 95% CI, 0.9%-1.7%), possibly concordant (5.5%, 95% CI, 5.0%-6.0%) and non-addressed (7.4%, 95% CI, 6.8%-8.0%). Among 125,631 outpatient placements, 50,181 (39.9%) had any prior long-term rhythm monitoring. Conclusion ILR placements are uncommon but increasing, with faster annual growth for indications that may not be guidance concordant. More than half of patients lacked long-term rhythm monitoring prior to outpatient ILR placement.
Matching journals
The top 6 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- The Effect of Medical Therapy on Reducing the Risk of Pacing Induced Cardiomyopathy 94%
- Surgical strategy for atrial functional mitral regurgitation with atrial fibrillation 94%
- Smartwatch Facilitated Remote Health Care for Patients Undergoing Transcatheter Aortic Valve Replacement Amid COVID-19 Pandemic 94%
Similar papers in this journal
- Sex and racial differences in cardiovascular disease risk in patients with atrial fibrillation 93%
- Applications of Machine Learning in Decision Analysis for Dose Management for Dofetilide 93%
- High-resolution Spatiotemporal Changes in Dominant Frequency and Structural Organization During Persistent Atrial Fibrillation 93%
Similar papers in this journal
- High Initial Heart Rate Score is an Independent Predictor of New Atrial High-Rate Episodes in Pacemaker Patients with Sinus Node Dysfunction 95%
- Procedural Volume and Outcomes with Atrial Fibrillation Ablation: A Report from the NCDR AFib Ablation Registry 95%
- Competing Risks in Patients with Primary Prevention Implantable Cardioverters Defibrillators: Global Electrical Heterogeneity and Clinical Outcomes (GEHCO) Study 94%
Similar papers in this journal
- Registration, Publication, and Outcome Reporting among Pivotal Clinical Trials that Supported FDA Approval of High-Risk Medical Devices Before and After FDAAA 90%
- Decision support system to evaluate VENTilation in the Acute Respiratory Distress Syndrome (DeVENT study) – Trial Protocol 90%
- Rationale and design of the Learning Implementation of Guideline-based decision support system for Hypertension Treatment (LIGHT) Trial and LIGHT-ACD Trial 88%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.