Quantitative Semisolid Magnetization Transfer and Relayed Nuclear Overhauser Effect Imaging in a Multiple Sclerosis Mouse Model Using Deep Magnetic Resonance Fingerprinting
Ben Chaim, R.; Rivlin, M.; Perlman, O.
Show abstract
Magnetic resonance imaging (MRI) is the imaging modality of choice for the diagnosis, characterization, and monitoring of multiple sclerosis (MS). Nevertheless, the contrasts manifested by MS lesions often overlap with those of other pathological conditions, highlighting the need for additional disease biomarkers. In addition, while saturation transfer (ST) MRI provides molecular information associated with myelin, protein, and lipids, quantifying the underlying proton exchange parameters remains challenging. Here, we describe a strategy that extends and modifies AI-boosted ST magnetic resonance fingerprinting (MRF) imaging at 7T. This approach was used to quantify the dynamics of the semisolid magnetization transfer (MT) and the aliphatic relayed nuclear Overhauser effect (rNOE at -3.5 ppm and -1.6 ppm relative to water) in a longitudinal cuprizone MS mouse model (n=12). In lipid phantoms, the reconstructed proton volume fractions were strongly correlated with known lipid concentrations across all three proton pools (r>0.96, p<0.001). In vivo, semisolid MT and rNOE proton volume fractions in the corpus callosum demonstrated a significant decrease (p<0.01) as early as week 4 of cuprizone feeding, preceding changes detected by conventional water relaxometry. ST-MRF based biomarkers were in agreement with histological findings. Overall, our results demonstrate the feasibility of rapid, multi-pool ST-MRF quantification for MS characterization.
Matching journals
The top 2 journals account for 50% of the predicted probability mass.
Similar papers in this journal
Similar papers in this journal
- Rapid Tissue-CSF Water Exchange in the Human Brain Revealed by Magnetization Transfer Indirect Spin Labeling 94%
- Mitochondrial Oxidative Phosphorylation Capacity in Skeletal Muscle Measured by Ultrafast Z-Spectroscopy (UFZ) MRI at 3T 94%
- MR Spectroscopy without Water Suppression using the Gradient Impulse Response Function 94%
Similar papers in this journal
- AI-powered Gradient Echo Plural Contrast Imaging (AI-GEPCI): a Comprehensive Multiparametric Neurological Protocol from a Single MRI Scan 94%
- Test-retest reproducibility of in vivo magnetization transfer ratio and saturation index in mice at 9.4 Tesla 92%
- T2-weighted T1 mapping and automated segmentation of CSF: Assessment of solute gradients in the healthy brain 92%
Similar papers in this journal
Similar papers in this journal
- An optimal 1H-MRS technique at 7T: Proof-of-principle in Chronic Multiple Sclerosis and Neuromyelitis Optica Brain Lesions and Normal Appearing Brain Tissue. 95%
- The dot-compartment revealed? Diffusion MRI with ultra-strong gradients and spherical tensor encoding in the living human brain 94%
- Detection of Nanoliter-Scale Cortical Perivascular Spaces Using Heavily T2-weighted MRI at 7T 93%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.