Performance verification of human field of view occluders for light measurement and simulation
Mardaljevic, J.; de Vries, S. W.; van Duijnhoven, J.
Show abstract
The measurement of light received at the cornea of the eye is a paramount consideration for the understanding of the relation between environmental illumination and the non-image-forming effects of light. The field of view (FOV) at the cornea is less than a full hemisphere, because it is partially occluded by human facial morphology. The International Commission on Illumination (CIE) has defined a standard model of human FOV. A suitably designed physical occluder attached to the sensor (of a light meter) has been proposed as a means of incorporating the effect of human FOV when taking measurements. Similarly, when using simulation to predict light received at the cornea, a geometrical description of the occluder at the eye point(s) can be added to the 3D model of the scene. The first occluder model proposed to represent CIE human FOV was enumerated in terms of: the CIE definition; the radius of the occluder; and, the radius of the light sensor disc. We present a simpler model based only on the CIE definition and the occluder radius. Both models were tested using a virtual goniophotometer. Various sensor response functions describing the spatial sensitivity across the sensor disc, including several we characterized through laboratory measurements, were included in the test. For all functions considered, the performance of the simpler occluder model was equivalent to or better than the model first proposed.
Matching journals
The top 4 journals account for 50% of the predicted probability mass.
Similar papers in this journal
Similar papers in this journal
- A simple method to separate birds and insects in single-pol weather radar data 89%
- High-resolution three-dimensional mapping of eelgrass (Zostera marina) habitat and blue carbon using drone-borne LiDAR 89%
- Individual tree-crown detection in RGB imagery using semi-supervised deep learning neural networks 88%
Similar papers in this journal
Similar papers in this journal
- A simple method for comparing peripheral and central color vision by means of two smartphones 95%
- PyPlr: A versatile, integrated system of hardware and software for researching the human pupillary light reflex 94%
- Measuring motion-to-photon latency for sensorimotor experiments with virtual reality systems 90%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.