Back

Breaking the seasonal barrier: feasibility of cuffless fingertip-based continuous blood pressure monitoring in older adults during winter exercise

Mizutani, N.; Nishizawa, S.; Enomoto, Y.; OKAMOTO, H.; Baba, R.; Misawa, A.; Takahashi, K.; Tada, Y.; LIN, Y.-C.; Shih, W.-P.

2026-04-16 health systems and quality improvement
10.64898/2026.04.14.26350440 medRxiv
Show abstract

While the need for continuous blood pressure (BP) monitoring in Japan is high, there are no commercially available cuffless devices for personal daily monitoring use. Fingertip-based sensors are a promising alternative as they eliminate the discomfort of repeated cuff inflation. However, their reliability during winter has been a major technical limitation due to cold-induced peripheral vasoconstriction. This study aimed to address this issue by validating a novel fingertip-based continuous BP monitor used by exercising adults during summer and winter. Eleven community-dwelling older adults (mean age, 73.1 {+/-} 8.8 years) were included in this seasonal comparative study. During exercise, we compared a personal fingertip-based continuous monitor (ArteVu) with a standard oscillometric cuff device (Omron) in summer (mean, 26.5{degrees}C) and winter (mean, 7.4{degrees}C). The study also evaluated the device's accuracy during exercise-induced BP fluctuations and seasonal environmental changes. Awareness of the participants regarding BP management was also assessed using questionnaires. There were strong correlations for systolic BP (SBP) between summer and winter (r = 0.93 in summer; r = 0.88 in winter). Although the mean difference for the SBP was higher in winter than in summer (3.1 {+/-} 11.2 mmHg vs. 0.2 {+/-} 9.4 mmHg), the values remained within a clinically acceptable range for personal monitoring. Notably, 72.7% of participants reported that the ease of using the fingertip-based device significantly increased their awareness and motivation for daily BP management. This study confirms the feasibility of cuffless fingertip-based continuous BP monitoring across different seasons, including in winter. By overcoming the seasonal limitations, this device fills a critical gap in the Japanese health-monitoring market. Our findings support the development of smaller and more portable models, representing a shift from traditional "snapshot" cuff measurements to continuous and integrated lifestyle monitoring for older adults.

Matching journals

The top 2 journals account for 50% of the predicted probability mass.

1
Sensors
39 papers in training set
Top 0.1%
42.6%
2
PLOS ONE
4510 papers in training set
Top 9%
18.8%
50% of probability mass above
3
Physiological Measurement
12 papers in training set
Top 0.1%
3.9%
4
Scientific Reports
3102 papers in training set
Top 32%
3.9%
5
Frontiers in Bioengineering and Biotechnology
88 papers in training set
Top 0.8%
2.5%
6
Environment International
42 papers in training set
Top 0.6%
1.8%
7
Physiological Reports
35 papers in training set
Top 0.4%
1.8%
8
Frontiers in Digital Health
20 papers in training set
Top 0.8%
1.3%
9
F1000Research
79 papers in training set
Top 3%
1.0%
10
Journal of the American Heart Association
119 papers in training set
Top 3%
1.0%
11
Frontiers in Public Health
140 papers in training set
Top 7%
1.0%
12
Computer Methods and Programs in Biomedicine
27 papers in training set
Top 0.8%
0.8%
13
Heliyon
146 papers in training set
Top 5%
0.8%
14
Frontiers in Cardiovascular Medicine
49 papers in training set
Top 2%
0.8%
15
BMJ Open
554 papers in training set
Top 12%
0.8%
16
Journal of Biomedical Optics
25 papers in training set
Top 0.7%
0.7%
17
Wellcome Open Research
57 papers in training set
Top 2%
0.7%
18
iScience
1063 papers in training set
Top 36%
0.7%
19
Cureus
67 papers in training set
Top 5%
0.7%
20
Science of The Total Environment
179 papers in training set
Top 5%
0.7%
21
Sleep Medicine
18 papers in training set
Top 0.4%
0.5%
22
Nature Communications
4913 papers in training set
Top 66%
0.5%
23
Journal of Personalized Medicine
28 papers in training set
Top 2%
0.5%
24
Biotechnology and Bioengineering
49 papers in training set
Top 1%
0.5%