Imaging solute transportation along the posterior lymphatic pathway in the ocular glymphatic system in healthy human participants
Wen, X.; Sun, Y.; Zhou, X.; Li, Y.; Paez, A.; Varghese, J.; Pillai, J. J.; Knutsson, L.; Van Zijl, P. C. M.; Leigh, R.; Kamson, D. O.; Graley, C. R.; Saidha, S.; Bakker, A.; Ward, B. K.; Kashani, A. H.; Hua, J.
Show abstract
Background: Recently, a posterior pathway for fluid drainage from the retina to the meningeal lymphatics in the optic nerve (ON) sheath was identified in rodents using intravitreal imaging tracers directly injected into the ocular-globe. Fluid and solute clearance along this pathway may be associated with many diseases. However, intravitreal tracers are rarely used in clinical imaging. As intravenous Gadolinium-based-contrast-agent (GBCA) can enter the globe via the blood-ocular-barriers, it may provide an alternative approach to image this pathway. Purpose: To establish a clinically feasible intravenous GBCA-based MRI approach for tracking fluid and solute transport along the posterior lymphatic pathway in the ocular glymphatic system. Materials & Methods: This prospective study was conducted from March 2021 to September 2022 in healthy participants. Dynamic-susceptibility-contrast-in-the-CSF (cDSC) MRI was performed before, immediately and 4 hours after intravenous-GBCA administration to track GBCA distribution in aqueous humor (AH) and cerebrospinal fluid (CSF) in regions-of-interest (ROIs) in the globe (anterior-cavity, vitreous-body), in the intraorbital and extraorbital ON, and in the intracranial CSF space proximal to the ON (chiasmatic-cistern, interpeduncular-cistern). Kruskal-Wallis tests with post-hoc Dunn's tests were used for group comparisons. Results: Sixteen healthy participants (mean age +/- SD: 51 +/- 21 years, 5 men) were recruited. Intravenous-GBCA enhancement was observed in all ROIs immediately after injection. At 4-hour-post-GBCA, the vitreous body showed a trend of smaller enhancement area (55 +/- 11% versus 49 +/- 11%, P=.14) and lower GBCA-concentration (0.044 +/- 0.014 versus 0.028 +/- 0.010 mmol/L, P=.07) compared to immediate-post-GBCA. The intraorbital ON showed more widespread enhancement (39 +/- 5% versus 59 +/- 6%, P=.01) and significantly higher GBCA-concentration (0.023 +/- 0.009 versus 0.059 +/- 0.015 mmol/L, P<.001) at 4-hour-post-GBCA. Conclusion: Dynamic fluid and solute transportation along the posterior lymphatic pathway in the ocular glymphatic system in healthy participants was measured by tracking intravenous-GBCAs entering the globe via the blood-ocular-barriers using cDSC-MRI.
Matching journals
The top 6 journals account for 50% of the predicted probability mass.