3D-DXA Cortical and Trabecular Parameters; Agreement and Precision Between GE Healthcare Prodigy and iDXA Densitometers
Krueger, D.; Binkley, N.; Madeira, M.; Chen, Z.; Di Gregorio, S.; Del Rio, L.; Humbert, L.
Show abstract
3D-DXA reconstructs DXA hip scans to 3-dimensional images allowing measurement of trabecular and cortical bone parameters. Given the higher image quality of GE Healthcare iDXA than GE Healthcare Prodigy, it could be hypothesized that the reconstruction might differ, thereby affecting 3D-DXA results. The aim of the study was to assess agreement and precision of 3D-DXA cortical and trabecular femur parameters between Prodigy and iDXA densitometers in adult subjects. The study cohort was composed of 391 men and women recruited from 3 clinical centers (USA and Brazil). All subjects were scanned on either Prodigy or iDXA scanners. Short-term precision was assessed on two Prodigy and two iDXA densitometers. 3D-DXA analyses were performed using 3D-Shaper software version 2.14. Agreement between densitometers was assessed by regression and Bland-Altman analyses. Short-term precision was determined following International Society for Clinical Densitometry recommendations. Strong agreements for 3D-DXA parameters were obtained between devices regardless of the center or the DXA device model (all R2 > 0.96). Bland-Altman analyses demonstrated statistically (p < 0.05), but not clinically, significant difference between both aBMD and 3D-DXA measurements obtained using Prodigy and iDXA scanners. Short-term precision of areal BMD and 3D-DXA parameters was similar between densitometers. This study demonstrated excellent 3D-DXA measurement agreement and similar precision between iDXA and Prodigy densitometers. These data provide evidence that no adjustments are required when using 3D-Shaper software on iDXA or Prodigy instruments. Mini AbstractWe assessed agreement and precision of 3D-DXA parameters between GE Healthcare Prodigy and iDXA densitometers in adults. Strong agreement was observed between devices, and short-term precision was comparable. Findings indicate that no adjustment is needed when using 3D-DXA with GE Healthcare densitometers.
Matching journals
The top 3 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Estimation equation of limb lean soft tissue mass in Asian athletes using bioelectrical impedance analysis 94%
- Intra- and inter-rater reliability, agreement, and minimal detectable change of the handheld dynamometer in individuals with symptomatic hip osteoarthritis 94%
- A way to break bones? The weight of intuitiveness 94%
Similar papers in this journal
- Large-scale quantification of human osteocyte lacunar morphological biomarkers as assessed by ultra-high-resolution desktop micro-computed tomography 96%
- Large-scale osteocyte lacunar morphological analysis of transiliac bone in normal and osteoporotic premenopausal women 95%
- Automated Segmentation of Fractured Distal Radii by 3D Geodesic Active Contouring of in vivo HR-pQCT Images 95%
Similar papers in this journal
- Definition of normal vertebral morphology using NHANES-II radiographs 94%
- Low Intensity Vibration Protects the Weight Bearing Skeleton and Suppresses Fracture Incidence in Boys with Duchenne Muscular Dystrophy 93%
- Assessment of bovine cortical bone fracture behavior using impact microindentation as a surrogate of fracture toughness 93%
Similar papers in this journal
- Clinical Observation of Diminished Bone Quality and Quantity through Longitudinal HR-pQCT-derived Remodeling and Mechanoregulation 95%
- Evaluation of longitudinal time-lapsed in vivo micro-CT for monitoring fracture healing in mouse femur defect models 94%
- Lactobacillus rhamnosus attenuates bone loss and maintains bone health by skewing Treg-Th17 cell balance in Ovx mice 94%
Similar papers in this journal
- A Novel Optimized Silver Nitrate Staining Method for Visualizing the Osteocyte Lacuno-Canalicular System 92%
- Characterisation of growth plate dynamics in murine models of osteoarthritis 91%
- Inspiratory Muscle Strength Training to Improve Cardiometabolic Health in Patients with Type 2 Diabetes Mellitus: Protocol for the Diabetes Inspiratory Training (DIT) Clinical Trial 88%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.