Electrical Impedance Spectroscopy to easily assess structural changes in dominant versus auxiliary upper arms due to pathophysiological events.
Dell'Osa, A. H.; Fois, A.; Mela, Q.; Loviselli, A.; Capone, A.; Marongiu, G.; Tocco, F.; Concu, A.; Velluzzi, F.
Show abstract
The resistive component of the bioimpedance was non invasively assessed in both right and left forearms of 11 healthy female and 9 males (28.4 {+/-} 1.4 years; 63.8 {+/-} 11.8 kg; 167.4 {+/-} 7.5 cm) all of which were right-handed. A homemade electrical impedance spectroscopy device which implemented the AD 5933 electronic board from Analog Devices Inc., USA, was utilized, and the bipolar modality of bioimpedance assessment was chosen using two disposable ECG surface electrodes placed in each end of the biceps brachial muscles while subject were comfortably sitting. Forearms resistance was acquired at sweeping frequencies steps of 15, 30, 45, 60 and 75 KHz. Results showed a significantly lower man value of resistance in right versus left forearms (- 27.4 {Omega}, P<0.05), or about -4%, at the frequency of 15 KHz. Even though there was a progressive reduction, this right versus left forearm resistance difference persisted as statistically significant up to the frequency of 45 KHz. It was concluded that the risk of some mistakes do exists when lymphedema may occur in one arm and electrical impedance spectroscopy was utilized to monitoring in that arm the water volume trend in comparison with the other side arm since these results underline in the main forearm a largely low value of the resistance than in the auxiliary one, even in healthy subjects. So, care must be taken when the electrical impedance spectroscopy was adopted in these clinical assessments.
Matching journals
The top 2 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Comparison of TENS electrodes and textile electrodes for electrocutaneous warning 95%
- Estimation equation of limb lean soft tissue mass in Asian athletes using bioelectrical impedance analysis 94%
- Impact of galvanic vestibular stimulation electrode current density on brain current flow patterns: Does electrode size matter? 94%
Similar papers in this journal
- Comparison of wearable and clinical devices for acquisition of peripheral nervous system signals 94%
- Feasibility of Ultra-Short Term Analysis of Heart Rate and Systolic Arterial Pressure Variability at Rest and During Stress via Time-domain and Entropy-based Measures 94%
- A computational study on the role of parameters for identification of thyroid nodules by infrared images (and its comparison with real data) 94%
Similar papers in this journal
Similar papers in this journal
Similar papers in this journal
- Tuning the Pennes Perfusion Rate to Model Large Vessel Cooling Effects in Hepatic Radiofrequency Ablation 91%
- Mechanical Efficiency Investigation of an ankle-assisted robot for human walking with a backpack-load 91%
- Experiments and Simulations to Assess Exercise-Induced Pressure Drop Across Aortic Coarctations 90%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.