A Prototype Thermoregulator for Prosthetic Socket Microenvironments in a Low-resourced Setting
Opoku-Gyamfi, D.; Agbewoavi, C. K.; Yamoah, Z.; Ansah, H. A.; Akwetey, B. Y.; Govindan, K.; Abiwu, N.
Show abstract
BackgroundThermal discomfort significantly hinders consistent prosthesis use among amputees, particularly in low-resource settings like Ghana, where conventional sockets often lead to passive heat accumulation and associated skin issues. MethodsA convection-based thermoregulator prototype was developed using widely available, open-source components. The system was integrated into a hard transtibial prosthetic socket with four strategically drilled ventilation holes. A rigorous bench-top experiment was conducted, employing a standardized heat gun to apply a consistent thermal load for 14 minutes, followed by a 26-minute cooling phase. Two identical setups were tested for direct comparison. Performance was evaluated and quantitative analysis of cooling rates using exponential decay models. ResultsThe active thermoregulator demonstrated superior cooling, reducing the experimental socket temperature from its peak to below the 35{degrees}C comfort threshold in approximately 8 minutes, achieving a total reduction of 13.9{degrees}C at an average rate of 0.53{degrees}C/min over the 26-minute cooling phase. In contrast, the control group exhibited a slower, natural cooling, with a total reduction of 6.5{degrees}C at an average rate of 0.25{degrees}C/min. Quantitative analysis of cooling constants confirmed the active systems rate (k=0.01/min) was 2.5 times greater than natural convection (k=0.004/min). These findings establish the fundamental feasibility of an active, convection-based thermoregulator for prosthetic sockets. ConclusionThe prototype effectively demonstrates the ability to actively dissipate heat, offering a significant improvement over passive cooling.
Matching journals
The top 8 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Open-source 3D Printable Forearm Crutch 94%
- Randomized, Crossover Clinical Trial on the Safety, Feasibility, and Usability of the ABLE Exoskeleton: A Comparative Study with Knee-Ankle-Foot Orthoses 92%
- Validity and reliability of an app-based medical device to empower individuals in evaluating their physical capacities 92%
Similar papers in this journal
- A Plantar Surface Shear Strain Methodology Utilising Digital Image Correlation 91%
- Nonthermal plasma treatment of polymers modulates biological fouling but can cause material embrittlement 90%
- An Investigation into Patient-Specific 3D Printed Titanium Stents and the use of Etching to Overcome Selective Laser Melting Design Constraints. 90%
Similar papers in this journal
- Wireless networks of injectable microelectronic stimulators based on rectification of volume conducted high frequency currents 92%
- Successful transfer of myoelectric skill from virtual interface to prosthesis control 92%
- A Block-Capable and Module-Extendable 4-Channel Stimulator for Acute Neurophysiology 92%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.