Back

Optimisation of radiographic visibility and wear detection of total knee arthroplasty inlays using radiopaque markers

Emonde, C. K.; Eggers, M.-E.; Heide, K. M.; Pape, F.; Marian, M.; Hurschler, C.; Ettinger, M.; Denkena, B.

2025-06-28 orthopedics
10.1101/2025.06.27.25330271 medRxiv
Show abstract

Wear of the inlay in total knee arthroplasty (TKA) contributes to implant failure and the need for revision surgery. In vivo wear assessment is challenging owing to the radiolucency of the inlay in standard radiographs. This study aimed to investigate the basic feasibility of integrating radiopaque X-ray markers on standard inlays to enhance their radiographic visibility and enable wear evaluation. Preliminary experiments identified optimal process parameters for micro-milling cavities on ultra-high molecular weight polyethylene (UHMWPE). A total of 450 parameter combinations were evaluated, with burr formation serving as the quality criterion. A process chain, comprising pre-contouring, micro-milling, filling cavities with radiopaque composite, and final contouring, was developed for inlay production. Eleven inlays with varying marker alignments, orientations, and geometries were manufactured, featuring grooves ([≤]0.8 mm wide) and holes (diameter = 1.6 mm), both 1 mm deep. Three HDPE + BaSO composites (10, 20, and 30 wt.% BaSO) were formulated and assessed for radiopacity per ASTM F640-20. Final marker cavities were filled with HDPE + 20 wt.% BaSO via pellet extrusion. The inlays were positioned in a phantom knee setup and radiographed in the anteroposterior view. Projected markers were evaluated based on edge visibility, measurability, homogeneity, and obscuration by the implant. None of the parameter combinations resulted in burr-free cavities, indicating an unstable five-axis process. X-ray images revealed that grooves aligned in the X-ray direction and drilled holes exhibited the best visibility for wear markers. Pin-on-plate tribological experiments revealed that BaSO addition to pure HDPE reduced its CoF from 0.25 to 0.1, reaching a value comparable to UHMWPE (0.15), while also enhancing wear resistance. This study demonstrated the feasibility of integrating wear markers on standard TKA inlays by micro-milling cavities at different positions and orientations on the inlay surface and filling them with a radiopaque composite. Further research is required to optimise process parameters and investigate marker wear.

Matching journals

The top 5 journals account for 50% of the predicted probability mass.

1
PLOS ONE
4510 papers in training set
Top 11%
15.2%
2
Applied Sciences
24 papers in training set
Top 0.1%
12.9%
3
Acta Biomaterialia
85 papers in training set
Top 0.1%
12.7%
4
Scientific Reports
3102 papers in training set
Top 9%
8.5%
5
Computational and Structural Biotechnology Journal
216 papers in training set
Top 0.9%
4.5%
50% of probability mass above
6
Annals of Biomedical Engineering
34 papers in training set
Top 0.3%
3.7%
7
Cureus
67 papers in training set
Top 2%
2.7%
8
Medical Physics
14 papers in training set
Top 0.3%
2.1%
9
International Journal of Molecular Sciences
453 papers in training set
Top 6%
1.9%
10
Bioengineering
24 papers in training set
Top 0.4%
1.7%
11
Frontiers in Human Neuroscience
67 papers in training set
Top 1%
1.5%
12
Journal of Orthopaedic Research
19 papers in training set
Top 0.2%
1.5%
13
Advanced Functional Materials
41 papers in training set
Top 1%
1.4%
14
Biomaterials Science
21 papers in training set
Top 0.3%
1.4%
15
Biomacromolecules
25 papers in training set
Top 0.2%
1.4%
16
Journal of Advanced Research
15 papers in training set
Top 0.4%
1.3%
17
BMJ Open
554 papers in training set
Top 10%
1.3%
18
Advanced Materials Technologies
27 papers in training set
Top 0.4%
1.3%
19
Bioactive Materials
18 papers in training set
Top 0.5%
1.3%
20
Journal of the Mechanical Behavior of Biomedical Materials
22 papers in training set
Top 0.2%
1.3%
21
International Journal of Biological Macromolecules
65 papers in training set
Top 3%
0.8%
22
Biomaterials Advances
20 papers in training set
Top 0.6%
0.8%
23
Journal of Clinical Medicine
91 papers in training set
Top 7%
0.7%
24
Frontiers in Bioengineering and Biotechnology
88 papers in training set
Top 3%
0.7%
25
Peer Community Journal
254 papers in training set
Top 5%
0.5%
26
Frontiers in Cell and Developmental Biology
218 papers in training set
Top 11%
0.5%