Back

A high-performance liquid chromatography-mass spectrometry method for simultaneous determination of dolutegravir, nevirapine, efavirenz, rifampicin and rifapentine concentrations in human plasma

Omali, D.; Ocan, M.; Lanyero, H.; Angwe, M. K.; Castelnuovo, B.; Buzibye, A.

2025-06-09 pharmacology and therapeutics
10.1101/2025.06.08.25329229 medRxiv
Show abstract

Variations in clinical pharmacokinetics and genetics, and polypharmacy affect attainment of target drug concentrations in HIV-TB co-infected patients. However, scarcity of analytical methods hinders drug concentration measurement for therapeutic drug monitoring in this doubly vulnerable population in low-and-middle income countries. This study aimed to develop and validate an LC-MS method for simultaneous determination of dolutegravir, nevirapine, efavirenz, rifampicin, isoniazid and rifapentine concentrations in plasma. ThermoScientific LCQ ion trap operated by Xcalibur software was used. Analyte extraction from plasma was achieved by protein precipitation using 100% acetonitrile. Injection volume was 30{micro}l for dolutegravir, efavirenz and nevirapine and 10{micro}l for rifampicin and rifapentine. Analyte separation was achieved on Waters Atlantis dC18 column by 400{micro}l flow rate of mobile phase under gradient elution. Transitions used were; dolutegravir (419.13[->]277.00), efavirenz (315.03[->]316.00), nevirapine (266.16[->]267.10), rifampicin (822.41[->]790.20), rifapentine (876.45[->]845.50), dolutegravir-d4 (423.13[->]280.10) and rifampicin-d4 (826.41[->]795.20). Calibration curves were constructed using quadratic regression with dynamic weighting of x = y, 1/x and 1/x2 and accepted at r2 [≥] 0.95 for all validation parameters. Method linearity and recovery ranged from 0.25{micro}g/ml to 10.00{micro}g/ml and 86.12% to 109.89% respectively for all analytes. Intra-and inter-day accuracy ranged from 88.73% to 109.67% and 93.38% to 104.30% respectively for all analytes. Both intra-and inter-day precision ranged from 2.47 RSD to 12.39 RSD and 5.34 RSD to 16.83 RSD respectively for all analytes. The method was selective and specific with no significant ghost peak identified in blank samples at expected retention times of dolutegravir, efavirenz, nevirapine, rifampicin and rifapentine. An LC-MS method for simultaneous determination of dolutegravir, efavirenz, nevirapine, rifampicin and rifapentine in human plasma was developed and validated. The method could be useful to the Uganda Ministry of Health for therapeutic drug monitoring in HIV-TB patients in health facilities in the country.

Matching journals

The top 7 journals account for 50% of the predicted probability mass.

50% of probability mass above

"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.