Unleashing the Potential of He OPM-MEG: A Comparison with SQUID-MEG for Detecting Interictal Epileptic Activity
Schwartz, d. P.; Badier, J.-M.; Gutteling, T.; Daligault, S.; Labyt, E.; Bonini, F.; Jung, J.
Show abstract
ObjectivesConventional magnetoencephalography (MEG) based on superconducting quantum interference devices sensors (SQUIDs), are the only widely used MEG systems in both clinical and research settings. However, they have limitations that hinder their widespread deployment. Optically pumped magnetometers (OPMs) offer several advantages over SQUIDs, particularly for epilepsy studies: lightweight and flexible, OPMs can be integrated into adaptable motion-tolerant headsets, enabling recordings during seizures or natural head movements, and potentially enhancing the detection of interictal epileptiform discharges (IEDs). In the present study, we assess the capabilities of a 5-sensors MEG system with helium OPMs (4He-OPMs) in detecting IEDs. MethodsFirst, we compare the performance of SQUID-MEG and 4He-OPM-MEG in a routine clinical setup with a group of 7 patients. Second, we perform combined intra-cerebral (SEEG) 4He-OPM-MEG and SQUID-MEG recordings in a single patient to demonstrate the ability of both systems to detect IEDs originating from deep brain structures. ResultsThe key finding is that, even with a very limited number of sensors, the 4He-OPM-MEG prototype successfully captured interictal epileptic activity in most patients. This activity was clearly detectable and exhibited the characteristic morphology with strikingly similar time courses between 4He-OPM-MEG and SQUID-MEG signals. Using combined SEEG and OPM-MEG recordings, we obtained the first direct validation of the ability of 4He OPM sensors to record epileptic activities originating from deep structures. SignificanceThese results strongly support the clinical adoption of a lightweight, high-sensitivity, whole-head 4He OPMs-MEG system, offering new perspectives for epilepsy diagnostics and beyond, and enabling the democratization and spread of MEG in clinical and research settings. Plain language summaryMagnetoencephalography is a non-invasive neuroimaging technique that has been shown to improve surgical outcomes in epileptic patients. However, its use remains limited due to several constraints, which could be overcome by a new generation of sensors: the optically pumped magnetometers (OPMs). Here, we validate the ability of OPM sensors to record epileptic brain activity in a regular clinical setup and thanks to simultaneous intracerebral recordings. These sensors open new venues for the widespread application of magnetoencephalography in the management of epilepsy and other neurological diseases, as well as for fundamental neuroscience. Key pointsO_LIEpileptic abnormalities are detected by 4He OPMs as well as with classical magnetoencephalography. C_LIO_LIHippocampal interictal activity can be detected by 4He OPMs as shown by simultaeous SEEG-OPM recordings. C_LIO_LIThis results represents significant step towards the validation of OPM-MEG for epilepsy diagnosis and neuroscience research. C_LI
Matching journals
The top 7 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Improved spatio-temporal measurements of visually evoked fields using optically-pumped magnetometers 95%
- Probabilistic comparison of gray and white matter coverage between depth and surface intracranial electrodes in epilepsy: a patient-specific modeling and empirical study 93%
- Target of selective auditory attention can be robustly followed with MEG 93%
Similar papers in this journal
- On-scalp MEG SQUIDs are sensitive to early somatosensory activity unseen by conventional MEG 95%
- Sensor localization using magnetic dipole-like coils: A method for highly accurate co-registration in on-scalp MEG 95%
- A multi-site, multi-participant magnetoencephalography resting-state dataset to study dementia: The BioFIND dataset 95%
Similar papers in this journal
- Detection of interictal epileptiform discharges: A comparison of on-scalp MEG and conventional MEG measurements 97%
- Fast oscillations >40Hz localize the epileptogenic zone: an electrical source imaging study using high-density electroencephalography 95%
- Optimizing Detection and Deep Learning-based Classification of Pathological High-Frequency Oscillations in Epilepsy 94%
Similar papers in this journal
Similar papers in this journal
- A studyforrest extension, MEG recordings while watching the audio-visual movie "Forrest Gump" 95%
- Simultaneous human intracerebral stimulation and HD-EEG: ground-truth for source localization methods 95%
- Open multimodal iEEG-fMRI dataset from naturalistic stimulation with a short audiovisual film 95%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.