Exploiting Zeta potential of air borne pathogenic bacteria for effective air decontamination
Peketi, A. S. K.; SVL, S. K. k.; P, K. K.; Bulagonda, E. P.
Show abstract
BackgroundAirborne microorganisms contribute significantly to hospital-associated infections (HAIs), particularly causing respiratory tract infections (RTIs). Multi-drug resistant (MDR) airborne pathogens pose a global clinical threat, challenging existing air decontamination technologies. While current methods effectively trap microbes, they often lack microbicidal properties. Exploitation of Zeta potential of microbes which are naturally charged could be a potential strategy for air decontamination, independent of their antimicrobial resistance. In this study, we tested the efficacy of ZeBox technology which relies on zeta potential to trap and eliminate airborne pathogens such as clinically isolated, MDR Klebsiella pneumoniae, Acinetobacter baumannii, Pseudomonas aeruginosa, Escherichia coli of respiratory origin and a non RTI isolate Staphylococcus aureus. MethodsFive MDR bacterial pathogens which include K. pneumoniae (2 nos), A. baumannii, P. aeruginosa, and E. coli from patients with RTI and one pus isolate of S. aureus were included in the study. These isolates were aerosolized in a certified BSL-2 setting containing a ZeBox-powered Air Sterilization device. Viable bacteria were enumerated before and after exposure to the Zebox powered device. Clinical and laboratory isolated bacterial strains were assessed for zeta potential variations to understand its association with antibiotic resistance and pathogenicity. ResultsOur analyses revealed that Zeta potential is species specific, but independent of the pathogenicity and antibiotic susceptibility of the tested bacteria. Exposure to Zebox powered device for 5 mins resulted in a remarkable decline of microbial load with a minimum 5 log reduction (99.999%) of all the tested isolates, irrespective of their species. Zeta potential measurements further indicated a consistent killing mechanism of MDR pathogens by Zebox technology. ConclusionsThe current study underscores the reliability of zeta potential based air decontamination strategies for potential elimination of diverse, air borne MDR bacteria in healthcare settings. HighlightsO_LIZeta potential value of bacteria is not influenced by AST or pathogenicity of bacteria. C_LIO_LIZeta potential driven device traps and kills airborne MDR bacteria with 99.999% efficiency. C_LIO_LIThe efficacy of ZeBox technology is consistent across pathogens. C_LI
Matching journals
The top 4 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Decontamination of Geobacillus Stearothermophilus Using the Arca Aerosolized Hydrogen Peroxide Decontamination System 95%
- A comparison of several media types and basic techniques used to assess outdoor airborne fungi in Melbourne, Australia. 95%
- N95 respirators, disposable procedure masks and reusable cloth face coverings: total inward leakage and filtration efficiency of materials against aerosol 95%
Similar papers in this journal
- Effectiveness of portable air filtration on reducing indoor aerosol counts: preclinical observational trials 95%
- Comparison of the in vitro-efficacy of different mouthwash solutions targeting SARS-CoV-2 based on the European Standard EN 14476 94%
- In vitro and in situ analysis of a novel copper-based antimicrobial surface coating designed to reduce the microbial bioburden of high touch surfaces in a hospital environment. 94%
Similar papers in this journal
- A low power flexible dielectric barrier discharge disinfects surfaces and improves the action of hydrogen peroxide 95%
- Scalable, effective, and rapid decontamination of SARS-CoV-2 contaminated N95 respirators using germicidal ultra-violet C (UVC) irradiation device 94%
- The virucidal effects of 405 nm visible light on SARS-CoV-2 and influenza A virus 94%
Similar papers in this journal
- Low-cost, local production of a safe and effective disinfectant for resource-constrained communities 94%
- The impact of heating, ventilation, and air conditioning design features on the transmission of viruses, including the 2019 novel coronavirus: a systematic review of ventilation and coronavirus 92%
- Prevalence and determinants of evidence of silicosis and impaired lung function, among small scale tanzanite miners and the peri-mining community in northern Tanzania 92%
Similar papers in this journal
- Exploration of the antimicrobial synergy between selected natural substances on Streptococcus mutans to identify candidates for the control of dental caries 93%
- Novel Pentafluorosulfanyl-containing Triclocarban Analogs selectively kill Gram-positive bacteria. 93%
- Generation of false positive SARS-CoV-2 antigen results with testing conditions outside manufacturer recommendations: A scientific approach to pandemic misinformation 92%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.