Evaluation of the diagnostic value of YiDiXie™-SS, YiDiXie™-HS and YiDiXie™-D in lung tumors

Li, X.; Chen, W.; Wang, W.; Sun, C.; Zhou, H.; Wu, Y.; Ge, Z.; Li, Y.; Lin, S.; Zhang, P.; Chen, S.; Li, W.; Chen, H.; Ji, L.; Liu, J.; Lai, Y.

2024-07-18 oncology
10.1101/2024.07.18.24310612 medRxiv
Show abstract

BackgroundLung cancer poses a serious threat to human health. Lung CT is widely used for lung tumor screening or initial diagnosis, while contrast-lung CT is extensively employed in lung tumor diagnosis. However, false-positive lung CT results can lead to misdiagnosis and incorrect surgery or treatment, while false-negative lung CT results can lead to missed diagnosis and delayed treatment. There is an urgent need to find convenient, cost-effective and non-invasive diagnostic methods to reduce the false-positive rate and false-positive rates of lung CT. The aim of this study was to evaluate the diagnostic value of YiDiXie-SS, YiDiXie-HS and YiDiXie-D, in lung cancer. Patients and methodsThis study finally included 1250 subjects (the malignant group, n=1078; the benign group, n=172). Remaining serum samples from the subjects were collected and tested using the YiDiXie all-cancer detection kit, which was applied to assess the sensitivity and specificity of YiDiXie-SS, YiDiXie-HS and YiDiXie-D, respectively. Results: YiDiXie-SS has a sensitivity of 97.5% (96.4% - 98.3%) and its specificity is 66.9% (59.5% - 73.5%). This means that YiDiXie-SS has very high sensitivity and high specificity in lung tumors.YiDiXie-HS has a sensitivity of 85.3% (83.0% - 87.2%) and its specificity is 83.1% (76.8% - 88.0%). This means that YiDiXie-HS has high sensitivity and high specificity in lung tumors.YiDiXie-D has a sensitivity of 73.9% (71.2% - 76.5%) and its specificity is 92.4% (87.5% - 95.5%). This means that YiDiXie-D has high sensitivity and very high specificity in lung tumors.YiDiXie-SS has a sensitivity of 98.2% (95% CI: 96.8% - 99.0%) and a specificity of 66.0% (95% CI: 51.7% - 77.8%) in patients with CT-positive tumors. This means that the application of YiDiXie-SS reduces the CT false-positive rate by 66.0% (95% CI: 51.7% - 77.8%) with essentially no increase in malignancy underdiagnosis. The sensitivity of YiDiXie-HS in CT negative patients was 84.2% (95% CI: 80.6% - 87.2%) and its specificity was 82.4% (95% CI: 74.8% - 88.1%). This means that the application of YiDiXie -HS reduces the false-negative lung CT rate by 84.2% (95% CI: 80.6% - 87.2%). YiDiXie-D has a sensitivity of 73.7% (70.1% - 77.1%) and a specificity of 93.6% (82.8% - 97.8%) in CT-positive patients. This means that YiDiXie -D reduces the rate of CT false positives by 93.6% (82.8% - 97.8%). YiDiXie-D has a sensitivity of 74.2% (70.1% - 78.0%) and a specificity of 92.0% (85.9% - 95.6%) in patients with a negative CT. This means that YiDiXie-D reduces the CT false-negative rate by 74.2% (70.1% - 78.0%) while maintaining high specificity. ConclusionYiDiXie-SS provides extremely high sensitivity and high specificity in lung tumors. YiDiXie-HS provides high sensitivity and high specificity in lung tumors. yiDiXie-D provides high sensitivity and very high specificity in lung tumors. YiDiXie -SS significantly reduces the rate of lung CT false positives with essentially no increase in delayed treatment of malignant tumors. YiDiXie-HS significantly reduces the false-negative rate of lung CT. YiDiXie-D can significantly reduce the false-positive rate of lung CT or significantly reduce the false-negative rate while maintaining high specificity. the YiDiXie test has important diagnostic value in lung cancer and is expected to solve the problems of "too high false-positive rate" and "too high false-negative rate" of lung CT. Clinical trial numberChiCTR2200066840.

Matching journals

The top 2 journals account for 50% of the predicted probability mass.

50% of probability mass above

"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.