Back

Diagnostic accuracy of automated Lumipulse plasma pTau-217 in Alzheimer disease

Cecchetti, G.; Agosta, F.; Rugarli, G.; Spinelli, E. G.; Ghirelli, A.; Zavarella, M.; Bottale, I.; Orlandi, F.; Santangelo, R.; Caso, F.; Magnani, G.; Filippi, M.

2024-05-20 neurology
10.1101/2024.05.20.24307613 medRxiv
Show abstract

INTRODUCTIONConsiderable advancements have occurred in blood-based Alzheimers disease (AD) biomarkers, with automated assays emerging for clinical use. Demonstrating the reliability of these automated systems is crucial with upcoming AD therapies. METHODSThis cross-sectional study in a Memory Center enrolled 98 patients along the AD continuum or affected by other neurodegenerative disorders, stratified by CSF A/T status and clinical syndrome. Plasma pTau-217, pTau-181, and A{beta}42/A{beta}40 were measured using Lumipulse. Relationships with CSF and glomerular filtration rate (GFR) were explored. ROC analysis was conducted to assess diagnostic performance. RESULTSGFR effect was lowered by the use of ratios and pTau-217 correlation with CSF was strong. Plasma pTau-217 discriminated A+/T+ status with excellent accuracy in both dementia and mild cognitive impairment (AUC 0.93-0.97), outperforming pTau-181 and A{beta}42/A{beta}40. Cutoffs displayed high diagnostic performance. DISCUSSIONLumipulse automated pTau-217 and identified cutoffs exhibit excellent diagnostic accuracy for CSF A+/T+ status and clinical group detection, facilitating future clinical translation.

Matching journals

The top 5 journals account for 50% of the predicted probability mass.

50% of probability mass above