New POCT instrument, GBTsol ICA system for HIV monitoring by CD4 and CD8 enumeration in resource-poor settings
aghamoradi, s.; Sung, S.; Kim, H.-S.; Song, J.; Lee, J.; Baek, S.
Show abstract
According to WHO report 39.0 million (33.1-45.7 million) people around the world were living with HIV infection till Dec of 2022. One method that we need for treatment and monitoring of HIV patients is CD4 counting and CD4/CD8 ratio. For this purpose, there are many different laboratory test with technical complexity and in other hand most of them are time consuming, expensive or cannot be used in resource limited places. This work demonstrates POCT microchip platform for enumerating leukocytes, CD4+ T- lymphocytes, and CD8+ T lymphocytes from whole blood, using fluorochrome-conjugated primary antibodies as a detection method. This device and its method omits all obstacles for WBC and CD4, CD8 T lymphocytes and it offers fast, cost effective and easy absolute WBC and CD4, CD8 T lymphocytes count for monitoring HIV patients immune situation with high accuracy which can be implemented insource limited stings or doctors office. We incubated Phycoerythrin (PE) conjugated primary antibodies specific to CD4 and CD8 antigens to enumerate CD4+ and CD8+ T cells, respectively. Comparison studies were performed with FACS count to evaluate total leukocytes, CD4+T cell number, and CD8+T cell number in whole blood samples for monitoring the immune systems of patients with human immunodeficiency virus (HIV)/AIDS. Statistical analyses for precision, correlation, and agreement were performed. Coefficients of variation (CV) ranging from 0.67% to 12.78%, 0.81 to 13.68%, and 0.29% to 8.33% were obtained for CD4, CD8 and leukocyte recovery respectively. A significant correlation was found between the two assays for CD4 count and CD8 count, with correlation coefficients of 0.90 and 0.91, respectively. Using Bland-Altman plots, a mean bias of 23, 38, and 490 cells/{micro}L (95% CI, n=113) was obtained for CD4, CD8, and total leukocyte count, respectively. These data show that the GBTsol ICA (Immune Cell Analyzer) is comparable to the FACS count platform method for measuring the amounts of CD4 T cells, CD8 T cells, and total leukocytes in blood samples for the purpose of monitoring HIV/AIDS patients with cheap, easy and fast way.
Matching journals
The top 1 journal accounts for 50% of the predicted probability mass.
Similar papers in this journal
- A High-throughput Microsphere-based Immunoassay of Anti-SARS-CoV-2 IgM Testing for COVID-19 Diagnostics 96%
- Analytical performance of 17 commercially available point-of-care tests for CRP to support patient management at lower levels of the health system 95%
- Evaluating diagnostic accuracies of Panbio ™ COVID-19 rapid antigen test and RT-PCR for the detection of SARS-CoV-2 in Addis Ababa, Ethiopia using Bayesian Latent-Class Models (BLCM) 95%
Similar papers in this journal
- Multispectral Imaging for MicroChip Electrophoresis Enables Point-of-Care Newborn Hemoglobin Variant Screening 96%
- High-sensitive detection and quantitation of thyroid-stimulating hormone (TSH) from capillary/fingerstick and venepuncture whole-blood using fluorescence-based rapid lateral flow Immunoassay (LFIA) 93%
- Retrospective and prospective studies evaluating the performance of the SARS-Cov-2 “AQ+ COVID-19 Ag Rapid Test” from InTec on symptomatic and non-symptomatic patients 93%
Similar papers in this journal
- Hilab system, a new point-of-care hematology analyzer supported by the Internet of Things and Artificial Intelligence 97%
- A serological assay to detect SARS-CoV-2 antibodies in at-home collected finger-prick dried blood spots 94%
- Are commercial antibody assays substantially underestimating SARS-CoV-2 ever infection? An analysis on a population-based sample in a high exposure setting 94%
Similar papers in this journal
- Evaluation of three rapid lateral flow antigen detection tests for the diagnosis of SARS-CoV-2 infection 95%
- Clinical evaluation of a SARS-CoV-2 RT-PCR assay on a fully automated system for rapid on-demand testing in the hospital setting 93%
- Pushing beyond specifications: Evaluation of linearity and clinical performance of a fully automated SARS-CoV-2 RT-PCR assay for reliable quantification in blood and other materials outside recommendations 93%
Similar papers in this journal
- Evaluation of seven different rapid methods for nucleic acid detection of SARS-COV-2 virus 96%
- Validation and Performance Comparison of Three SARS-CoV-2 Antibody Assays 94%
- Clinical evaluation of an automated, rapid mariPOC ® antigen test in screening of symptomatics and asymptomatics for SARS-CoV-2 infections 94%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.