Efficacy and Safety of Magnetic Seed Pre-Operative Non-Palpable Breast Lesion Localization: a series of 37 consecutive cases.
Bouvier, M.; Abrahami, Y.; Belaroussi, I.; El Bejjani, M.-R.; Beranger, S.; Cascarino, M.; Afriat, R.; Lotersztajn, N.; Alran, S.
Show abstract
Context40% of breast surgery patients have a lesion that requires preoperative localization, a process that demands close cooperation between radiological and surgical team. Magnetic seed localization is a new tracking technique which does not require programming the day before or on the day of the intervention. The aim of our study was to evaluate the efficacy and safety of magnetic localization of non-palpable breast lesions. Methods and patientsThis is a study of 39 consecutive preoperative ultrasound-guided implantations of a magnetic seed (MS) in 37 patients, for non-palpable breast lesions, performed at the Breast Center at Saint-Joseph Hospital in Paris, France, between May 15th and December 21st, 2018. One patient who was operated on for papillomatous lesions had a double magnetic seed implanted. In the operating room, the MS was percutaneously localized by a magnetic probe. The ex-vivo magnetism was noted and the removed tissue was sent to radiology to look for the MS, after which it was sent for histopathological examination. All localized lesions had previously been biopsied, and there were 29 infiltrative cancers, 7 atypical lesions, and 3 benign lesions. The sentinel node was identified by super paramagnetic iron peroxide in 11 cases, and by isotopes in the 18 others. ResultsOur patients were on average 57 years old (33-86 years old). All magnetic localization was realized using ultrasound. The mean ultrasound size of the lesions was 12.7 mm (5-34mm). The period of time from implantation to surgery varied from 0 to 21 days. The localization method was characterized by a rapid pose, facilitated by the excellent luminosity of the needle for the tracking. No compression pad was needed, optimizing the implementation and quality of the control mammography. The mean time for the tissue resection from incision to excision was 15 minutes for the first 10 cases. On the radiography of removed tissue: the clip was present in 38 out of 39 cases. One failure was registered, in relation to loss of the clip, found in the tumorectomy limits, in the patient with the double localization procedure. However, the target was effectively removed and detected histo-pathologically. In the 13 cases of super paramagnetic iron peroxide, the sentinel node was identified each time. All biopsied lesions were removed, and in cancerous lesions, the surgical margins were healthy in all cases. ConclusionThe MS localization technique is reliable and safe. For the patient, the main interest is a simplified procedure without long-term damage of the skin; for the radiologist, the rapidity of the procedure; for the surgeon, a real time guide for localizing the target; and for the hospital, an eased organization with regard to preoperative tracking during ambulatory surgery, with implantations possible up to 1 month prior to surgery, for instance at the time of the radiological review. The main limit to MSs development remains its cost.
Matching journals
The top 3 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- A Machine Learning Ensemble Based on Radiomics to Predict BI-RADS Category and Reduce the Biopsy Rate of Ultrasound-Detected Suspicious Breast Masses 95%
- The NILS study protocol - a retrospective validation study of a preoperative decision-making tool for non-invasive lymph node staging in women with primary breast cancer [ISRCTN14341750] 93%
- Passive Microwave Radiometry (MWR) for diagnostics of COVID-19 lung complications in Kyrgyzstan 88%
Similar papers in this journal
- Automated and Manual Quantification of Tumour Cellularity in Digital Slides for Tumour Burden Assessment 91%
- Towards integration of 64Cu-DOTA-Trasztusumab PET-CT and MRI with mathematical modeling to predict response to neoadjuvant therapy in HER2+ breast cancer 90%
- Development and Validation of Collaborative Robot-assisted Cutting Method for Iliac Crest Flap Raising: Randomized Crossover Trial 90%
Similar papers in this journal
- Evaluation of the efficacy of using indocyanine green associated with fluorescence in sentinel lymph node biopsy 96%
- Improved accuracy of breast volume calculation from 3D surface imaging data using statistical shape models 96%
- Silicone Induced Granuloma of Breast Implant Capsule (SIGBIC) diagnosis: Breast Magnetic Resonance (BMR) ability to detect silicone bleeding. 93%
Similar papers in this journal
- Palliative care in the treatment of women with breast cancer: a scoping review protocol 91%
- Protocol for a prospective cohort study on the feasibility of application of nutritional ultrasound in the diagnosis and follow-up of patients with nutritional risk at hospital discharge: Study on body composition and function (DRECO) 88%
- Patterns of peritoneal dissemination and response to systemic chemotherapy in common and rare peritoneal tumors treated by cytoreductive surgery: Study protocol of a prospective, multi-center, observational study 88%
Similar papers in this journal
- Association between Hormonal Contraceptive Use and Lipedema: A Cross-Sectional Study with 637 Brazilian Women 87%
- Effects of contrast-medium and vertebral measurement level on computed tomography-based body composition parameters of skeletal muscle and adipose tissue 87%
- Dosimetric Analysis of Fast Forward Breast Radiotherapy Using 3D-CRT with Deep Inspiration Breath Hold(DIBH) 87%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.