Reducing Motor Variability Enhances Myoelectric Control Robustness Across Limb Positions
Stuttaford, S. A.; Dyson, M.; Nazarpour, K.; Dupan, S. S. G.
Show abstract
BackgroundThe limb position effect is a multi-faceted problem, associated with decreased upper-limb prosthesis control acuity following a change in arm position. The many factors contributing to this problem can arise from distinct environmental or physiological sources. Despite their differences in origin, the effect of each factor manifests similarly as increased variability in the detected control signal. This variability can cause incorrect decoding of user intent, leading to dropped items or inability to use the prosthesis during activities of daily living. The general approach of previous research has attempted to limit the impact of the factors or better capture the variability with data abundance. In this paper we take an alternative approach and investigate the effect of reducing the variability of the control signal by improving the consistency of muscle activity with user training. MethodsParticipants underwent 4 days of myoelectric training with either concurrent or delayed feedback in a single arm position. During this time, they were trained to control a two-dimensional cursor using muscles in the forearm. At the end of training participants underwent a zero feedback retention test in multiple limb positions. In doing so, we tested how well the skill learned in a single limb position generalized to untrained positions. ResultsWe found that delayed feedback training led to more consistent muscle activity across both the trained and untrained limb positions. Analysis of patterns of activation in the delayed feedback group suggest a structured change in muscle activity occurs across arm positions. The structured changes allowed us to quantify the limb position effect by comparing trained to untrained arm positions. Different limb positions changed mean ECR and FCR muscle activity in the range of -4.3% to +18.7%. All participants were able to counter the limb position effect if given concurrent feedback, confirming our results align with existing findings. ConclusionsOur results demonstrate that myoelectric user-training can lead to the retention of motor skills that are more robust to limb position changes. This work highlights the importance of reducing motor variability with practice, prior to examining the underlying structure of muscle changes associated with limb position. These findings will be useful for the majority of myoelectric prosthesis control systems and will create better quality input data leading to more robust machine-learning based prosthesis control systems.
Matching journals
The top 4 journals account for 50% of the predicted probability mass.
Similar papers in this journal
Similar papers in this journal
Similar papers in this journal
- Validation of two-dimensional video-based inference of finger kinematics with pose estimation 96%
- Gaze and Movement Assessment (GaMA): Inter-site validation of a visuomotor upper limb functional protocol 96%
- Reaching to inhibit a prepotent response: a wearable 3-axis accelerometer kinematic analysis 95%
Similar papers in this journal
- Comparison of vibrotactile and joint-torque feedback in a myoelectric upper-limb prosthesis 96%
- Brain-Computer Interface Robotics for Hand Rehabilitation After Stroke: A Systematic Review 96%
- Technology-aided assessment of functionally relevant sensorimotor impairments in arm and hand of post-stroke individuals 95%
Similar papers in this journal
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.