Novel paradigm enables accurate monthly gestational screening to prevent congenital toxoplasmosis and more
Zhou, Y.; Leahy, K.; Grose, A.; Lykins, J.; Siddiqui, M.; Leong, N.; Goodall, P.; Withers, S.; Ashi, K.; Schrantz, S.; Tesic, V.; Abeleda, A. P.; Beavis, K.; Clouser, F.; Ismail, M.; Christmas, M.; Piarrox, R.; Limonne, D.; Chapey, E.; Abraham, S.; Baird, I.; Thibodeau, J.; Boyer, K.; Torres, E.; Conrey, S.; Wang, K.; Staat, M. A.; Back, N.; Gomez Martin, J.; Peyron, F.; Houze, S.; Wallon, M.; McLeod, R.
Show abstract
BackgroundCongenital toxoplasmosis is a treatable, preventable disease, but untreated causes death, prematurity, loss of sight, cognition and motor function, and substantial costs worldwide. Methods/FindingsIn our ongoing USA feasibility/efficacy clinical trial, data collated with other ongoing and earlier published results proved high performance of an Immunochromatographic-test(ICT) that enables accurate, rapid diagnosis/treatment, establishing new paradigms for care. Overall results from patient blood and/or serum samples tested with ICT compared with gold-standard-predicate-test results found ICT performance for 4606 sera/1876 blood, 99.3%/97.5% sensitive and 98.9%/99.7% specific. However, in the clinical trial the FDA-cleared-predicate test initially caused practical, costly problems due to false-positive-IgM results. For 58 persons, 3/43 seronegative and 2/15 chronically infected persons had false positive IgM predicate tests. This caused substantial anxiety, concerns, and required costly, delayed confirmation in reference centers. Absence of false positive ICT results contributes to solutions: Lyon and Paris France and USA Reference laboratories frequently receive sera with erroneously positive local laboratory IgM results impeding patient care. Therefore, thirty-two such sera referred to Lyons Reference laboratory were ICT-tested. We collated these with other earlier/ongoing results: 132 of 137 USA or French persons had false positive local laboratory IgM results identified correctly as negative by ICT. Five false positive ICT results in Tunisia and Marseille, France, emphasize need to confirm positive ICT results with Sabin-Feldman-Dye-test or western blot. Separate studies demonstrated high performance in detecting acute infections, meeting FDA, CLIA, WHO ASSURED, CEMark criteria and patient and physician satisfaction with monthly-gestational-ICT-screening. Conclusions/SignificanceThis novel paradigm using ICT identifies likely false positives or raises suspicion that a result is truly positive, rapidly needing prompt follow up and treatment. Thus, ICT enables well-accepted gestational screening programs that facilitate rapid treatment saving lives, sight, cognition and motor function. This reduces anxiety, delays, work, and cost at point-of-care and clinical laboratories. Authors SummaryToxoplasmosis is a major health burden for developed and developing countries, causing damage to eyes and brain, loss of life and substantial societal costs. Prompt diagnosis in gestational screening programs enables treatment, thereby relieving suffering, and leading to > 14-fold cost savings for care. Herein, we demonstrate that using an ICT that meets WHO ASSURED-criteria identifying persons with/without antibody to Toxoplasma gondii in sera and whole blood with high sensitivity and specificity, is feasible to use in USA clinical practice. We find this new approach can help to obviate the problem of detection of false positive anti-T.gondii IgM results for those without IgG antibodies to T.gondii when this occurs in present, standard of care, predicate USA FDA cleared available assays. Thus, this accurate test facilitates gestational screening programs and a global initiative to diagnose and thereby prevent and treat T.gondii infection. This minimizes likelihood of false positives (IgG and/or IgM) while maintaining maximum sensitivity. When isolated IgM antibodies are detected, it is necessary to confirm and when indicated continue follow up testing in [~]2 weeks to establish seroconversion. Presence of a positive ICT makes it likely that IgM is truly positive and a negative ICT makes it likely that IgM will be a false positive without infection. These results create a new, enthusiastically-accepted, precise paradigm for rapid diagnosis and validation of results with a second-line test. This helps eliminate alarm and anxiety about false-positive results, while expediting needed treatment for true positive results and providing back up distinguishing false positive tests.
Matching journals
The top 8 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Comparative Analysis of Commercially Available Typhoid Point of Care Tests: Results of a Prospective and Hybrid Retrospective Multicenter Diagnostic Accuracy Study in Kenya and Pakistan 94%
- Clinical Development and Performance of the First To Know ® Syphilis Self-Test for Over-the-Counter Usage: a De Novo Rapid Test for Treponemal Antibody 94%
- Performance and Implementation Evaluation of the Abbott BinaxNOW Rapid Antigen Test in a High-throughput Drive-through Community Testing Site in Massachusetts 94%
Similar papers in this journal
- Clinical evaluation of the Diagnostic Analyzer for Selective Hybridization (DASH): a point-of-care PCR test for rapid detection of SARS-CoV-2 infection 94%
- Evaluation of SARS-CoV-2 Antibody Point of Care Devices in the Laboratory and Clinical Setting 94%
- Assessing the performance of a serological point-of-care test in measuring detectable antibodies against SARS-CoV-2 94%
Similar papers in this journal
- Performance of Repeat BinaxNOW SARS-CoV-2 Antigen Testing in a Community Setting, Wisconsin, November-December 2020 94%
- Evaluating the accuracy of self-collected swabs for the diagnosis of monkeypox 93%
- Stool processing methods for Xpert Ultra testing in childhood tuberculosis: A prospective, multi-country accuracy study 92%
Similar papers in this journal
- A highly sensitive and specific SARS-CoV-2 spike- and nucleoprotein-based fluorescent multiplex immunoassay (FMIA) to measure IgG, IgA and IgM class antibodies 94%
- Evaluation of the INDICAID™ COVID-19 Rapid Antigen Test in symptomatic populations and asymptomatic community testing 94%
- Performance of the Cue COVID-19 Molecular Test for Point of Care: Insights from a multi-site clinic service model 93%
Similar papers in this journal
- Target product profiles for new diagnostics to inform strongyloidiasis control programs 94%
- Perceptions and priorities for the development of multiplex rapid diagnostic tests for acute non-malarial fever in rural South and Southeast Asia: an international modified e-Delphi survey 93%
- Evaluation of a rapid lateral flow assay for the detection of taeniosis and cysticercosis at district hospital level in Tanzania: A prospective multicentre diagnostic accuracy study 93%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.