BackgroundScarce data exist regarding the occurrence of mitral valve interference after transcatheter aortic valve replacement (TAVR) with Venus-A valve implantation. Several case reports have noted that the anterior mitral leaflet (AML) is mechanically affected by the prosthesis frame, particularly when implanted in a low position. This study aimed to investigate the potential factors influencing the clinical outcomes of AML interference after Venus-A valve implantation. MethodsWe retrospectively included 20 severe aortic valve stenosis patients who had undergone TAVR and had been implanted with the Venus-A valve at our hospital between October 2020 and June 2021. Pre- and post-procedural CT scans were used for the FEops HEARTguide simulation. Anatomically influencing factors were measured using the 3mensio software and derived from the FEops HEARTguide. The prosthesis-AML interference (PAI) was defined when it met both of two criteria:1) significant interference and limited AML movement shown by transthoracic or transoesophageal echocardiography, and 2) more than half cell intersection between the simulated Venus-A valve and the reconstructed AML revealed by the FEops HEARTguide. Anatomical factors and clinical outcomes were compared between the PAI and non-PAI groups. ResultsNine PAI patients and 11 non-PAI cases were identified. PAI was associated with shorter mitral-aortic annulus distance (2.7{+/-}1.7 mm vs 5.0{+/-}2.2 mm, P = 0.019), larger prosthesis valve size (P = 0.013), deeper implantation (12.2{+/-}3.3 mm vs 6.2{+/-}2.9 mm at non-coronary cusp side, P < 0.001) and less calcification of non-coronary cusp (median calcification score, 52.2 mm3 vs 156.0 mm3, P = 0.046). Regarding the clinical impact, PAI was associated with a higher rate of moderate or severe perivalvular leakage before discharge than those associated with the absence of PAI, with no difference in haemodynamic parameters and incidence of adverse events at the 30-day and 12-month follow-ups between the groups. ConclusionsInterference between the Venus-A prosthesis valve and AML after TAVR was associated with a shorter mitral-aortic annulus distance, larger prosthesis usage, greater implantation depth, and less calcification of the non-coronary cusp. However, further studies are required to explore its long-term clinical impact.
Matching journals
The top 6 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Patient Screening for Self-Expanding Percutaneous Pulmonary Valves using Virtual Reality 97%
- Smartwatch Facilitated Remote Health Care for Patients Undergoing Transcatheter Aortic Valve Replacement Amid COVID-19 Pandemic 96%
- Surgical strategy for atrial functional mitral regurgitation with atrial fibrillation 95%
Similar papers in this journal
- Mechanical effects of MitraClip on leaflet stress and myocardial strain in functional mitral regurgitation: A finite element modeling study. 96%
- Effects of low versus high inspired oxygen fraction on myocardial injury after transcatheter aortic valve implantation: A randomized clinical trial 96%
- {-}CardiOvascular examination in awake Orangutans (Pongo pygmaeus pygmaeus): Low-stress Echocardiography including Speckle Tracking imaging (the COOLEST method) 95%
Similar papers in this journal
- Ticagrelor vs Clopidogrel: the Impact of Platelet Inhibition on Cerebrovascular Microembolic Events during TAVR 95%
- Sex-Related Outcomes of Transcatheter Aortic Valve Implantation with Self-Expanding or Balloon-Expandable Valves: Insights from the OPERA-TAVI Registry 95%
- Investigating Electrocardiographic Abnormalities in Patients with Coronary Microvascular Dysfunction 94%
Similar papers in this journal
- Improved Hemodynamic Performance and Reduced Paravalvular Regurgitation with the SAPIEN 3 Ultra RESILIA Valve: A Propensity-Matched Single-Center TAVR Study 96%
- Autologous cardiac micrografts as support therapy to coronary artery bypass surgery 95%
- Results of the inoperable and operable with aortic valve endocarditis 94%
Similar papers in this journal
- Cardiac electrophysiological remodeling associated with enhanced arrhythmia susceptibility in a canine model of elite exercise 91%
- Multiplex immunohistochemistry differences between Q fever and atherosclerotic abdominal aortic aneurysms indicate immune suppression 91%
- Derivation and Internal Validation of Prediction Models for Pulmonary Hypertension Risk Assessment in a Cohort Inhabiting Tibet, China 91%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.