Diagnosis of left atrial appendage thrombus using cardiac computed tomography: new insights from thrombi locations
guo, c.; Jiang, Z.; He, J.; Ma, H.; Wang, Y.; Tan, J.; Ou, Q.; Tian, Y.; Tian, L.; Liu, Q.; Huang, J.; Yang, L.
Show abstract
BackgroundCardiac computed tomography (CCT) is an emerging non-invasive modality for assessing left atrial appendage (LAA) thrombus, but the results were conflicting. Our study aims to evaluate the accuracy of CCT for detecting LAA thrombus in patients undergoing catheter ablation of atrial fibrillation (AF), using transesophageal echocardiography (TEE) as the reference standard. MethodsFrom May 2017 to December 2022, 726 patients (male: 60.2%, age: 61{+/-}11 years) who had both TEE and CCT before catheter ablation of AF were retrospectively included. The CCT protocol consisted of one angiographic phase and one delayed scan 30 seconds later. LAA thrombi were defined as solid masses on TEE or persistent defects on CCT. The thrombus dimension and location, the LAA filling and emptying flow velocity were assessed by TEE. ResultsOf the 57(7.9%) patients with LAA thrombi identified by TEE, 29(50.9%) were located at the LAA ostium, and 28(49.1%) were in the LAA. The former showed higher motility following blood flow and heartbeats than the latter. The CCT detected 14(48.3%) of the LAA-ostium thrombi but 25(89.3%) of those in the LAA (p = 0.001). The LAA-ostium thrombi with the LAA mean flow velocity higher than 0.35m/s and maximum diameters shorter than 10mm were more prone to have CCT false-negative results. ConclusionFor patients undergoing catheter ablation for AF, CCT with a 30s delay scan is less sensitive to LAA thrombi than TEE, especially LAA-ostium thrombi with smaller sizes and higher LAA flow velocity. Clinical perspective section What are new?O_LIOver half of the LAA thrombi were located at the LAA ostium. C_LIO_LIThe CCT was less sensitive to the LAA-ostium thrombi with smaller sizes and higher LAA flow velocity. C_LI What is the clinical implication?1. The CCT using a 30s delay scan did not reliably exclude the LAA thrombi for the patients scheduled for pulmonary vein isolation, especially those located at the LAA ostium.
Matching journals
The top 4 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Catheter Ablation Approach Targeting Epicardial Connections to the Right Pulmonary Vein Antrum Detected before Pulmonary Vein Isolation 97%
- Impact of transseptal puncture location on the fossa ovalis on first-pass pulmonary vein isolation 97%
- Procedural Volume and Outcomes with Atrial Fibrillation Ablation: A Report from the NCDR AFib Ablation Registry 96%
Similar papers in this journal
- Surgical strategy for atrial functional mitral regurgitation with atrial fibrillation 96%
- Smartwatch Facilitated Remote Health Care for Patients Undergoing Transcatheter Aortic Valve Replacement Amid COVID-19 Pandemic 96%
- Relationship of mild to moderate impairment of left ventricular ejection fraction with fatal ventricular arrhythmic events in cardiac sarcoidosis 95%
Similar papers in this journal
- Atrial functional substrates for the prediction of atrial fibrillation recurrence after pulmonary vein isolation 97%
- Investigating Electrocardiographic Abnormalities in Patients with Coronary Microvascular Dysfunction 95%
- Prognostic value of compact myocardial thinning in patients with left ventricular non-compaction 95%
Similar papers in this journal
- Cardiac electrophysiological remodeling associated with enhanced arrhythmia susceptibility in a canine model of elite exercise 92%
- Derivation and Internal Validation of Prediction Models for Pulmonary Hypertension Risk Assessment in a Cohort Inhabiting Tibet, China 92%
- Personalized Computational Modeling Identifies Embolic Stroke of Undetermined Source Patients with Potential Arrhythmic Substrate 92%
Similar papers in this journal
- Evaluation of the second-generation whole-heart motion correction algorithm (SSF2) used to demonstrate the aortic annulus on cardiac CT 95%
- Deep Learning-based Prediction of Early Cerebrovascular Events after Transcatheter Aortic Valve Replacement 94%
- Reduced stress perfusion in myocardial infarction with nonobstructive coronary arteries 94%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.