Clinical and real-world evaluation of a fingernail selfie smartphone app for noninvasive, individually-personalized estimation of blood hemoglobin levels
Mannino, R. G.; Lopez, P.; Sullivan, J.; Whitson, J.; Tumlin, J.; Tyburski, E. A.; Lam, W. A.
Show abstract
Patients with chronic anemia, or low blood hemoglobin levels, are frequently subjected to the cost, inconvenience, and discomfort of traditional hematology analyzer-based measurements of blood hemoglobin levels via complete blood counts. Elimination of the need for complete blood count testing for hemoglobin screening is an unmet clinical need that we previously addressed by developing a non-invasive smartphone app that estimates hemoglobin levels via image analysis of fingernail bed images. In this work, we present additional data yielding significant improvement upon our previously established technology and describe the clinical validation, and real-world translation of the technology into a commercial product. To improve accuracy and create a clinical use case, we trained the app algorithm on individuals with chronic anemia to personalize the image analysis algorithm for estimating hemoglobin levels. Individual-level differences associated with using the app (variations between individuals, how a user captures images, the specific smartphone they use, the lighting conditions in the location they take the pictures, and biological variability within a population) appear to be the greatest source of measurement variability within larger sample sets. Therefore, we hypothesized that personalization of the algorithm could correct for user-to-user variability and translate to improved accuracy at the individual level. To test this hypothesis, we trained and tested personalized algorithms for individuals in clinical and "real world" settings. We enrolled 35 chronically anemic subjects [a chronic kidney disease (CKD) cohort] in a clinical study wherein the app algorithm was trained using complete blood count data and paired fingernail bed images, then tested against complete blood count data at subsequent study timepoints. After personalization, testing data revealed a mean absolute error (MAE) of 0.74 g/dL with a root mean squared error (RMSE) of 0.97 g/dL across all testing visits across all subjects, a significant improvement when compared to performance without personalization in the same user group (1.36 g/dL MAE and 1.70 g/dL RMSE, p = 3.13E-11). The app was also used in the "real world" by real app users who self-reported lab/complete blood count blood draw results. App performance findings were consistent with analysis of self-reported data from 17 individuals using our app. After training of the individual app algorithm in the "real world", testing data revealed a mean absolute error (MAE) of 0.62 g/dL with a root mean squared error (RMSE) of 0.85 g/dL when 4 training data points were used, an improvement when compared to performance of the app without personalization in the same user group (0.71 g/dL MAE and 1.27 g/dL RMSE). The personalized app accuracy is similar to that of other noninvasive Hgb measurement technologies currently on the market as medical devices with US Food & Drug Administration (US FDA) clearance. Thus, our technology represents a significant step forward towards true personalized medicine in a digital healthcare setting.
Matching journals
The top 1 journal accounts for 50% of the predicted probability mass.
Similar papers in this journal
Similar papers in this journal
- Smartphone screening for neonatal jaundice via ambient-subtracted sclera chromaticity: neoSCB app pilot study 93%
- Evaluation of the Practicability of a Finger-Stick Whole-Blood SARS-Cov-2 Self-Test Adapted for the General Population. 92%
- Impact of Skin Tone, Environmental, and Technical Factors on Thermal Imaging 91%
Similar papers in this journal
- Reducing the Cost of Rapid Antigen Tests through Swab Pooling and Extraction in a Device 90%
- Commercially-available heart rate monitor repurposed into a 9-gram standalone device for automatic arrhythmia detection with snapshot electrocardiographic capability: a pilot validation 89%
- A simple, cost-effective and extraction-free molecular diagnostic test for sickle cell disease in noninvasive buccal swab specimen for a limited-resource setting 89%
Similar papers in this journal
- Automated Image Transcription for Perinatal Blood Pressure Monitoring Using Mobile Health Technology 93%
- Racial disparities in continuous glucose monitoring-based 60-min glucose predictions among people with type 1 diabetes 92%
- Feasibility characteristics of wrist-worn fitness trackers in health status monitoring for post-COVID patients in remote and rural areas 91%
Similar papers in this journal
- Biometric linkage of longitudinally collected electronic case report forms and confirmation of subject identity: An open framework for ODK and related tools 93%
- Remote digital measurement of visual and auditory markers of Major Depressive Disorder severity and treatment response. 91%
- At-home blood collection and stabilization in high temperature climates using homeRNA 90%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.