Severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) was first diagnosed in December 2019. Since then this virus has caused an ongoing wide pandemic. Accurate diagnostic tests for SARS-CoV-2 are used to prevent the virus from spreading. However, these tests could not keep up with the demand and were not available in all places. Self-testing devices are easy-to-use-tests and reduce the demand in the diagnostic laboratories. The Antigen Rapid Test evaluated in this study uses oral fluid which is a non-invasive technique compared to nasopharyngeal swabs. In this study the COVID-19 Antigen Rapid Test (Oral fluid) was evaluated with 150 SARS-CoV-2 positive saliva specimens and 350 SARS-CoV-2 negative saliva specimens. The Antigen Rapid Test was performed according to the instruction manual. SARS-CoV-2 Real-time RT-PCR was used as Golden Standard. Although the criteria of the WHO are specific to nasal / nasopharyngeal samples (and not saliva), the specificity of the Antigen Rapid Test meets the criteria of the World Health Organization (WHO; specificity [≥] 97%). The test meets the WHO sensitivity criteria in samples with higher viral loads (Ct<30), showing the better performance of the test in highly positive samples. For positive SARS-CoV-2 specimens with a Ct value lower than 30 a sensitivity of 83.8% (95% CI: 80.1%-86.8%) and an accuracy of 95.9% (95% CI: 93.7%-97.4%) was observed. This shows that this assay with saliva samples is able to meet the high standards set by the WHO. The performance of the test is comparable to other antigen rapid tests reported in meta-analyses. Furthermore, the test allows self-testing which is non-invasive, affordable and straightforward. This antigen rapid test may provide an affordable, quick, and easy to perform method to differentiate between individuals with high and low viral loads.
Matching journals
The top 8 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Evaluation of GENECUBE ® HQ SARS-CoV-2 for anterior nasal samples and saliva samples with a new rapid examination protocol 96%
- Evaluating diagnostic accuracies of Panbio ™ COVID-19 rapid antigen test and RT-PCR for the detection of SARS-CoV-2 in Addis Ababa, Ethiopia using Bayesian Latent-Class Models (BLCM) 95%
- Development And Performance Evaluation of A Rapid In-House ELISA for Retrospective Serosurveillance of SARS-CoV-2 95%
Similar papers in this journal
- Evaluation of seven different rapid methods for nucleic acid detection of SARS-COV-2 virus 96%
- Real-life performance of a novel antigen detection test on nasopharyngeal specimens for SARS-CoV-2 infection diagnosis: a prospective study 96%
- Evaluation Of A New “All In One” Sars-Cov-2 Antigen-Detecting Rapid Diagnostic Test And Self-Test: Diagnostic Performance And Usability On Child And Adult Population 95%
Similar papers in this journal
- Evaluation and modelling of the performance of an automated SARS-CoV-2 antigen assay according to sample type, target population and epidemic trends 96%
- SalivaSTAT: Direct-PCR and pooling of saliva samples collected in healthcare and community setting for SARS-CoV-2 mass surveillance 96%
- Feasibility and diagnostic accuracy of saliva-based SARS-CoV-2 screening in educational settings and children aged < 12 years 95%
Similar papers in this journal
- Evaluation of SARS-CoV-2 rapid antigen diagnostic tests for saliva samples 96%
- Retrospective and prospective studies evaluating the performance of the SARS-Cov-2 “AQ+ COVID-19 Ag Rapid Test” from InTec on symptomatic and non-symptomatic patients 95%
- Development of a simple and highly sensitive virion concentration method to detect SARS-CoV-2 in saliva 94%
Similar papers in this journal
- Evaluation of RNA extraction free method for detection of SARS-COV-2 in salivary samples for mass screening for COVID-19 98%
- Expression of nitric oxide synthase and nitric oxide levels in peripheral blood cells and oxidized low-density lipoprotein levels in saliva as early markers of severe dengue 93%
- Comparison of primer-probe sets among different master mixes for laboratory screening of Severe Acute Respiratory Syndrome - Coronavirus 2 (SARS-CoV-2) 91%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.