Complete sequence verification of plasmid DNA using the Oxford Nanopore Technologies' MinION device
Brown, S. D.; Dreolini, L.; Wilson, J. F.; Balasundaram, M.; Holt, R. A.
Show abstract
BackgroundSequence verification is essential for plasmids used as critical reagents or therapeutic products. Typically, high-quality plasmid sequence is achieved through capillary-based Sanger sequencing, requiring customized sets of primers for each plasmid. This process can become expensive, particularly for applications where the validated sequence needs to be produced within a regulated and quality-controlled environment for downstream clinical research applications. ResultsHere, we describe a cost-effective and accurate plasmid sequencing and consensus generation procedure using the Oxford Nanopore Technologies MinION device as an alternative to capillary-based plasmid sequencing options. This procedure can verify the identity of a pure population of plasmid, either confirming it matches the known and expected sequence, or identifying mutations present in the plasmid if any exist. We use a full MinION flow cell per plasmid, maximizing available data and allowing for stringent quality filters. Pseudopairing reads for consensus base calling reduces read error rates from 5.3 % to 0.53 %, and our pileup consensus approach provides per-base counts and confidence scores, allowing for interpretation of the certainty of the resulting consensus sequences. For pure plasmid samples, we demonstrate 100 % accuracy in the resulting consensus sequence, and the sensitivity to detect small mutations such as insertions, deletions, and single nucleotide variants. In test cases where the sequenced pool of plasmids contains subclonal templates, detection sensitivity is similar to that of traditional capillary sequencing. ConclusionsOur pipeline can provide significant cost savings compared to outsourcing clinical-grade sequencing of plasmids, making generation of high-quality plasmid sequence for clinical sequence verification more accessible. While other long-read-based methods offer higher-throughput and less cost, our pipeline produces complete and accurate sequence verification for cases where absolute sequence accuracy is required.
Matching journals
The top 6 journals account for 50% of the predicted probability mass.
Similar papers in this journal
Similar papers in this journal
- PIPETS: A statistically informed, gene-annotation agnostic analysis method to study bacterial termination using 3'-end sequencing. 94%
- PtWAVE: A High-Sensitive deconvolution software of sequencing trace for the Detection of Large Indels in Genome Editing 94%
- nPoRe: n-Polymer Realigner for improved pileup variant calling 94%
Similar papers in this journal
- ConSeqUMI, an error-free nanopore sequencing pipeline to identify and extract individual nucleic acid molecules from heterogeneous samples 96%
- Rapid, robust plasmid verification by de novo assembly of short sequencing reads 96%
- Nanopore sequencing undergoes catastrophic sequence failure at inverted duplicated DNA sequences 95%
Similar papers in this journal
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.