Intraoperative adjustment of radiographic standard projections of the spine: Interrater- and intrarater variance and consequences of fluoro-hunting considering time and radiation exposure. A cadaveric study
Mandelka, E.; El Barbari, J.; Kausch, L.; Privalov, M.; Gruetzner, P. A.; Vetter, S. Y.; Franke, J.
Show abstract
BackgroundFor the acquisition of intraoperative fluoroscopic images, standard projections have to be manually adjusted. This process resembles a trial-and-error process and is therefore time-consuming and leads to increased radiation exposure for both patient and staff. In addition, the standard projections adjusted are subject to intra- and interindividual variance. However, to date, only very limited data exist in the literature quantifying the time and radiation exposure caused by the process of manually setting standard projections as well as the intra- and interindividual variance for the manual adjustment of standard projections. Material and MethodsA.p. and lateral standard projections of the vertebral bodies of two fresh-frozen specimen were manually adjusted by two examiners with a different level of experience using a mobile C-arm. The time needed for manual adjustment as well as the number of X-ray shots acquired and the radiation dose caused during this process were documented. Intra- and interindividual variance of the central beam, the orbital rotation and angulation of the C-arm was analyzed. ResultsThe median time needed was 75.9s, with no significant difference between the examiners (p=0.13). 7.1 x-ray images were acquired in average to reach subjective satisfaction with the standard projection with significantly more x-ray shots for the lateral standard (p=0.04) and for the examiner with less experience (p<0.001). Accordingly, the dose caused was more than 50% higher than for the experienced examiner (p=0.01). Mean interindividual variance of the central beam was 7.6{degrees} while the intraindividual variance was 4.2{degrees}. ConclusionIn summary, this study investigated the interrater and intrarater variance for standard manual level setting in the thoracic and lumbar spine. Additionally, we were able to quantify the time and number of radiographs required for this procedure for different levels of experience, as well as the resulting radiation dose.
Matching journals
The top 4 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Investigating the relationship between internal spinal alignment and back shape in patients with scoliosis using PCdare: a comparative, reliability and validation study 96%
- National diagnostic reference levels for digital diagnostic and screening mammography in Uganda. 95%
- Optimizing costs and sustainability for Gamma Knife Radiosurgery: A cost and breakeven analysis at India’s largest Neurosurgery Centre 93%
Similar papers in this journal
- AI-based image quality assessment in CT 91%
- Adverse events following COVID-19 virus vaccination in Japanese young population: The first cross-sectional study conducted by a questionnaire survey after the first-time-injection 90%
- Adverse events following COVID-19 vaccination in young Japanese people: A case-control study of the risk of systemic adverse events by a questionnaire surveyShort title: COVID-19 vaccine adverse events in young Japanese 89%
Similar papers in this journal
- Development and Validation of Collaborative Robot-assisted Cutting Method for Iliac Crest Flap Raising: Randomized Crossover Trial 93%
- Evaluation of longitudinal time-lapsed in vivo micro-CT for monitoring fracture healing in mouse femur defect models 93%
- Content-based image retrieval assists radiologists in diagnosing eye and orbital mass lesions in MRI 92%
Similar papers in this journal
- Effects of contrast-medium and vertebral measurement level on computed tomography-based body composition parameters of skeletal muscle and adipose tissue 91%
- Validation of the patient reported outcome measures tool “Catquest” in Odia language 91%
- Dosimetric Analysis of Fast Forward Breast Radiotherapy Using 3D-CRT with Deep Inspiration Breath Hold(DIBH) 91%
Similar papers in this journal
- Recent advances in the clinical applications of machine learning in proton therapy 90%
- Breast density prediction from low and standard dose mammograms using deep learning: effect of image resolution and model training approach on prediction quality 87%
- Model uncertainty estimates for deep learning mammographic density prediction using ordinal and classification approaches 86%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.