First experiences of whole-head OP-MEG recordings from a patient with Epilepsy
Mellor, S. J.; Vivekananda, U.; O'Neill, G. C.; Tierney, T. M.; Doig, D.; Seymour, R. A.; Alexander, N.; Walker, M. C.; Barnes, G. R.
Show abstract
Optically Pumped Magnetometer based Magnetoencephalography (OP-MEG) has significant potential for clinical use in pre-surgical planning in epilepsy. Unlike current clinical MEG, the sensors do not require cryogenic cooling and so can be placed directly on the patients head. This allows the patient to move during the recording and means that the sensor positions can be chosen to suit the patients head shape and suspected epileptogenic focus. However, OP-MEG is a new technology, and more work is needed to demonstrate this potential. We present OP-MEG recordings from a patient (male in their 30s) with a radiologically identifiable focal cortical dysplasia (FCD) in the right superior frontal sulcus approximately 1.9 cm3 in volume. Previous scalp EEG studies and prolonged video-EEG telemetry did not identify any interictal epileptiform abnormalities. We recorded 30 minutes of OP-MEG with 62-channel, whole-head sensor coverage. During the experiment, the patients head was unconstrained. We localised interictal epileptiform discharges (IEDs) from this recording with a beamformer and by fitting a dipole to the averaged IED data. Both the beamformer peak and dipole fit locations were within 2.3 cm of the MRI lesion boundary. This single subject, proof-of-concept recording provides further evidence that OP-MEG can be a useful and minimally invasive tool in the clinical evaluation of epilepsy.
Matching journals
The top 5 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Detection of interictal epileptiform discharges: A comparison of on-scalp MEG and conventional MEG measurements 97%
- Fast oscillations >40Hz localize the epileptogenic zone: an electrical source imaging study using high-density electroencephalography 96%
- Introducing RELAX (the Reduction of Electroencephalographic Artifacts): A fully automated pre-processing pipeline for cleaning EEG data - Part 1: Algorithm and Application to Oscillations 94%
Similar papers in this journal
- 40 Hz Steady-State Visually Evoked Potentials Recovered During Oscillating Transcranial Electrical Stimulation 92%
- EPOC outside the shield: comparing the performance of a consumer-grade EEG device in shielded and unshielded environments. 91%
- Biophysical modeling of the electric field magnitude and distribution induced by electrical stimulation with intracerebral electrodes 87%
Similar papers in this journal
- Magnetoencephalography can reveal deep brain network activities linked to memory processes 97%
- Estimating functional EEG sources using topographical templates 94%
- Data-driven beamforming techniques to attenuate ballistocardiogram (BCG) artefacts in EEG-fMRI without detecting cardiac pulses in electrocardiography (ECG) recordings 94%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.