Direct detection of microorganisms responsible for the sexually transmitted infection on the mobile real-time PCR device without treating in advance
Muraoka, M.; Sohma, K.; Kawaguchi, O.; Mizukoshi, M.
Show abstract
As WHO reported, four curable STIs-chlamydia, gonorrhoea, syphilis and trichomoniasis occur more than 1 million per each day globally almond 2016. For this reason, it is important to control these STIs, one of which is "to detect". The general methods in order to detect STIs are nucleic acid amplification tests (NAATs). One of the reasons why NAATs are utilized in many tests is that it is possibly to be more sensitive than other test. However, there needs to treat extraction of nucleic acids in advance and amplify specific regions by NAATs, and hence it must take much labour and much time. In this work, for Chlamydia trachomatis (CT), Neisseria gonorrhoeae (NG) and Treponema pallidum (TP) which is each etiological agent of chlamydia, gonorrhoea and syphilis, we evaluate and propose "quicker and simpler" NAATs. Specifically, utilizing mobile real-time PCR device "PCR1100" and PCR reagent kit "KAPA3G Plant PCR Kit", it was considered whether real-time direct PCR could be performed or not without treating DNA extraction in advance so-called "direct". As a result, firstly, we established that real-time direct PCR could be performed in all of CT, NG, and TP, and moreover, each Ct value correlated with the concentration of each organism similarly to detection of genome DNA (each correlation coefficient R2 > 0.95). Moreover, each assay demonstrated a limit of detection (LOD) of the follows; CT was 10^0.86 = 7.24 IFU/reaction, NG was 10^-0.19 = 0.65 CFU/reaction, and TP was 10^1.4 = 25.1 organisms/reaction. However, it appeared the sensitivity was a little low, especially for CT and TP. Secondly, we found that even as without treating sample in advance, the time of detection was required more less 15 minutes at any of case, which was very quick compared with other current methods for real-time PCR. Additionally, compared with other commercial devices, it was easier to operate the PCR1100 device, for example, start, analysis of Ct value. In conclusion, the present study has demonstrated that it is possible for real-time direct PCR to perform with combination of the PCR1100 device and the PCR reagent kit in 3 kinds of microorganisms-CT, NG and TP. Furthermore, we propose "quicker and simpler" methods for NAATs, which it would not take labour and time. Further studies are needed in order to contribute to control STIs.
Matching journals
The top 9 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Evaluating diagnostic accuracies of Panbio ™ COVID-19 rapid antigen test and RT-PCR for the detection of SARS-CoV-2 in Addis Ababa, Ethiopia using Bayesian Latent-Class Models (BLCM) 97%
- SARS-CoV-2 detection in multi-sample pools in a real pandemic scenario: a screening strategy of choice for active surveillance 97%
- Rapid detection of Pecan Root-Knot Nematode, Meloidogyne partityla, in laboratory and field conditions using loop-mediated isothermal amplification 96%
Similar papers in this journal
- Evaluation of seven different rapid methods for nucleic acid detection of SARS-COV-2 virus 97%
- Amplification of human β-glucoronidase gene for appraising the accuracy of negative SARS-CoV-2 RT-PCR results in upper respiratory tract specimens 95%
- Detection Of Early HIV-1 Infection Among Febrile Persons And Blood Donors In Oyo State, Nigeria 94%
Similar papers in this journal
- Simple, sensitive and cost-effective detection of wAlbB Wolbachia in Aedes mosquitoes, using loop mediated isothermal amplification combined with the electrochemical biosensing method 96%
- The Accuracy of Histopathological and Cytopathological Techniques in the Identification of the Mycetoma Causative Agents 95%
- Evaluation of Fecal Immunoassays for Canine Echinococcus Infection in China 95%
Similar papers in this journal
- Performance of microbiological tests for tuberculosis diagnostic according to the type of respiratory specimen: a 10-year retrospective study 94%
- Clinical, immunological and genomic characterization of asymptomatic and symptomatic cases with SARS-CoV-2 infection, India 93%
- Wide application of minimally processed saliva on multiple RT-PCR kits for SARS-CoV-2 detection in Indonesia 93%
Similar papers in this journal
- Development and validation of cost-effective one-step multiplex RT-PCR assay for detecting the SARS-CoV-2 infection using SYBR Green melting curve analysis 95%
- Development and Validation of LAMP Primer Sets for Rapid and Correct Identification of Aspergillus fumigatus Carrying the cyp51A TR46 Azole Resistance Gene 95%
- Climate influences scrub typhus occurrence in Vellore, Tamil Nadu, India: Analysis of a 15 year dataset 94%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.