Electronic Computer-Based Model of Combined Ventilation Using a New Medical Device
Ramos, M.; Orofino, R.; Riva, D.; Biancolini, M. F.; Lugones, I.
Show abstract
IntroductionThe increased demand for mechanical ventilation caused by the SARS-CoV-2 pandemic could generate a critical situation where patients may lose access to mechanical ventilators. Combined ventilation, in which two patients are ventilated simultaneously but independently with a single ventilator has been proposed as a life-saving bridge while waiting for new ventilators availability. New devices have emerged to facilitate this task and allow individualization of ventilatory parameters in combined ventilation. In this work we run computer-based electrical simulations of combined ventilation. We introduce an electrical model of a proposed mechanical device which is designed to individualize ventilatory parameters, and tested it under different circumstances. Materials and MethodsWith an electronic circuit simulator applet, an electrical model of combined ventilation is created using resistor-capacitor circuits. A device is added to the electrical model which is capable of individualizing the ventilatory parameters of two patients connected to the same ventilator. Through computational simulation, the model is tested in different scenarios with the aim of achieving adequate ventilation of two subjects under different circumstances: 1) two identical subjects; 2) two subjects with the same size but different lung compliance; and 3) two subjects with different sizes and compliances. The goal is to achieve the established charge per unit of size on each capacitor under different levels of end-expiratory voltage (as an end-expiratory pressure analog). Data collected included capacitor charge, voltage, and charge normalized to the weight of the simulated patient. ResultsSimulations show that it is possible to provide the proper charge to each capacitor under different circumstances using an array of electrical components as equivalents to a proposed mechanical device for combined ventilation. If the pair of connected capacitors have different capacitances, adjustments must be made to the source voltage and/or the resistance of the device to provide the appropriate charge for each capacitor under initial conditions. In pressure control simulation, increasing the end-expiratory voltage on one capacitor requires increasing the source voltage and the device resistance associated with the other simulated patient. On the other hand, in the volume control simulation, it is only required to intervene in the device resistance. ConclusionsUnder simulated conditions, this electrical model allows individualization of combined mechanical ventilation.
Matching journals
The top 3 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Computational simulation to assess patient safety of uncompensated COVID-19 two-patient ventilator sharing using the Pulse Physiology Engine 96%
- PVP1–The People’s Ventilator Project: A fully open, low-cost, pressure-controlled ventilator 95%
- Sharing ventilators in the Covid-19 pandemics. A bench study 95%
Similar papers in this journal
- A simple agent-based hybrid model to simulate the biophysics of glioblastoma multiforme cells and the concomitant evolution of the oxygen field 91%
- Digitizing ECG image: new fully automated method and open-source software code 91%
- An algorithm to detect dicrotic notch in arterial blood pressure and photoplethysmography waveforms using the iterative envelope mean method 91%
Similar papers in this journal
- Cardiorespiratory physiological perturbations after acute smoke-induced lung injury and during extracorporeal membrane oxygenation support in sheep 91%
- A Systematic Investigation of Detectors for Low Signal-to-Noise Ratio EMG Signals 90%
- Findings of a feasibility study of pre-operative pulmonary rehabilitation to reduce post-operative pulmonary complications in people with chronic obstructive pulmonary disease scheduled for major abdominal surgery. 89%
Similar papers in this journal
- Design and execution of a Verification, Validation, and Uncertainty Quantification plan for a numerical model of left ventricular flow after LVAD implantation 94%
- Age-dependent ventilator-induced lung injury: Mathematical modeling, experimental data, and statistical analysis 94%
- Hierarchical semantic composition of biosimulation models using bond graphs 92%
Similar papers in this journal
- A Predictive Nomogram for In-ICU Deterioration of Stage 1 Pressure Injuries: A Retrospective Study 89%
- Machine Learning-based Clinical Decision Support for Infection Risk Prediction 88%
- Predictive validity of the simplified Radiographic Assessment of Lung Edema score for the mortality in critically ill COVID-19 patients with the B.1.617.2 (Delta) variant in Vietnam: a single-centre, cross-sectional study 88%