A Survey of Provider Satisfaction of a New, Flexible Extended-Length Pharyngeal Airway to Relieve Upper Airway Obstruction During Deep Sedation
McMurray, R. R.; Gordan, L.
Show abstract
BackgroundMaintaining an open airway in a spontaneously-breathing patient under deep sedation, or deep monitored anaesthesia care, can be challenging. Specifically, current oral airways are not long enough to displace obstruction caused by redundant pharyngeal tissue, prompting external maneuvers by anesthetists that can impact patient outcomes and facility operational efficiency. As procedures increase at outpatient surgical centers, there is a need for an anesthesia provider-validated airway device that can sufficiently open an obstructed airway and maintain airway patency. MethodsThis prospective, multi-center user-experience survey evaluated anesthesia provider experience of a new airway device for adult patients with airway obstruction during deep sedation. The novel external airway has a longer flexible tubing allowing for displacement of pharyngeal tissue, smaller diameter to allow placement alongside an endoscopy bite block, and is manufactured with softer material to allow ease of insertion and patient comfort. ResultsFifty-four anaesthetists at 15 hospital systems reported their experience of airway use in 86 cases. The novel airway device was 95% successful in establishing and maintaining a patent airway (n=68). Survey responses indicated that the airway was easy to place (93%), allowed for a "hands-off approach" (98%), and would improve airway management practice and patient outcomes (86%). ConclusionsThis pilot study demonstrated that the novel external airway is an effective and satisfactory method for anaesthesia providers to alleviate airway obstruction during deep sedation. Additional studies will be initiated to confirm efficacy and cost-effectiveness in patient populations and clinical environments that will most benefit from the new airway device.
Matching journals
The top 2 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Virtual reality as a strategy for intra-operatory anxiolysis and pharmacological sparing in patients undergoing breast surgeries: the V-RAPS randomized controlled trial protocol 95%
- The Impact of a Wireless Audio System on Communication in Robotic-Assisted Laparoscopic Surgery: A Prospective Controlled Trial 94%
- Association between epidural catheter tip malposition and anesthesiologists’ experience after graduation: a cross-sectional study using postoperative CT images 93%
Similar papers in this journal
- DALES - a prospective cross-sectional study of incidence of penicillin allergy labels, risk of true allergy and attitudes of patients and anaesthetists to de-labelling strategies 91%
- Effect of Telemedicine Support for Intraoperative Anaesthesia Care on Postoperative Outcomes: The TECTONICS Randomised Clinical Trial 91%
- The impact of female sex on anaesthetic awareness, depth and emergence: A systematic review and meta-analysis 91%
Similar papers in this journal
- Findings of a feasibility study of pre-operative pulmonary rehabilitation to reduce post-operative pulmonary complications in people with chronic obstructive pulmonary disease scheduled for major abdominal surgery. 90%
- Cardiorespiratory physiological perturbations after acute smoke-induced lung injury and during extracorporeal membrane oxygenation support in sheep 88%
- Recommendations from long-term care reports, commissions, and inquiries in Canada 87%
Similar papers in this journal
- A quantitative evaluation of aerosol generation from upper airway suctioning during tracheal intubation and extubation sequences 93%
- Effectiveness of portable air filtration on reducing indoor aerosol counts: preclinical observational trials 87%
- Cleaning and disinfecting surfaces in hospitals and long-term care facilities for reducing hospital and facility-acquired bacterial and viral infections: A systematic review 87%
Similar papers in this journal
- Decontamination of filtering facepiece respirators in primary care using medical autoclave 92%
- Medication errors during simulated paediatric resuscitations: a prospective, observational human reliability analysis 90%
- Hydrocortisone for the prevention of postoperative delirium in digestive surgery (HyPOD): Study protocol for a multicentre randomized, blind, placebo-controlled trial 90%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.