Measuring Intertrochanteric Fracture Stability with a Novel Strain-Sensing Sliding Hip Screw
Carrington, N. T.; Millhouse, P. W.; Behrend, C. J.; Pace, T. B.; Anker, J. N.; DesJardins, J. D.
Show abstract
BackgroundBone healing after internal fixation of intertrochanteric hip fractures is difficult to monitor with radiography, particularly with internal fixation implants such as the sliding hip screw (SHS). In this study, we evaluate a robust, user-friendly device to non-invasively determine the loading on the screw implant. This will allow clinicians to better monitor the status of bone healing and take preventative steps if complications occur. MethodsA novel strain-sensing sliding hip screw (SS-SHS) was designed and refined using a finite element model of a simple intertrochanteric fracture and a standard SHS implant. The SS-SHS houses an internally fixed indicator rod, whose position relative to the screw body can be viewed on plain film radiographs to measure screw bending. Screw bending was assessed in an intact femur and an unstable A1 intertrochanteric fracture using a finite element computational model and compared with experimental axial loading of a femoral Sawbones composite and human cadaveric femur specimens. Indicator rod position relative to the screw was visually tracked using plain radiographs at each load state. ResultsThe indicator rod was found to displace linearly in response to implant strain in the unstable fracture. This movement was consistently visible and measurable using radiography throughout loading cycles across the mechanical and cadaveric fracture models. Sensor movement was not detected in healed fracture models. The slope of the curve was approximately equal in the computations, composite and cadaveric models (0.08 {micro}m/N, 1.0 {micro}m/N, 0.08 {micro}m/N, respectively). The noise level was approximately 25 N in the composite model and 63 N in the cadaveric specimen and this was sufficient to see 1/10th of body weight or more for an 80 kg patient which is likely good enough to track fracture healing. ConclusionsIn current practice, clinicians must carefully monitor their patients for signs of implant failure after surgery. However, by the time signs of failure are apparent, it is often too late to avoid revision surgery. This device enables clinicians to quantitatively track fracture healing, and better communicate the process to the patient. Clinicians can also take preventive measures with at-risk patients before revision surgery is needed, thus reducing mortality risks. Clinical RelevanceBy augmenting an existing SHS system with an indicator rod, crucial information on the status of fracture healing can be ascertained from follow-up radiographs already taken with no additional risk to the patient.
Matching journals
The top 8 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Correlation of two different devices for the evaluation of primary implant stability depending on dental implant length and bone density: an in vitro study 94%
- Development of the mandibular curve of Spee and maxillary compensating curve: A finite element model 93%
- Lateral pressure equalisation as a principle for designing support surfaces to prevent deep tissue pressure ulcers 93%
Similar papers in this journal
- Are Electromyography data a fingerprint for patients with cerebral palsy (CP)? 89%
- Novel application method for mesenchymal stem cell therapy utilizing its attractant-responsive accumulation property 89%
- Genetic deletion of interleukin-15 is not associated with major structural changes following experimental post-traumatic knee osteoarthritis in rats 88%
Similar papers in this journal
- Evaluation of longitudinal time-lapsed in vivo micro-CT for monitoring fracture healing in mouse femur defect models 94%
- Development and Validation of Collaborative Robot-assisted Cutting Method for Iliac Crest Flap Raising: Randomized Crossover Trial 93%
- Runaway resorption of microcracks contributes to age-related hip-fracture patients 93%
Similar papers in this journal
- How osteons form: A quantitative hypothesis-testing analysis of cortical pore filling and wall asymmetry 92%
- Automated Segmentation of Fractured Distal Radii by 3D Geodesic Active Contouring of in vivo HR-pQCT Images 92%
- The Effect of Celecoxib and muMab911 on Strain Adaptive Bone Remodeling and Fracture Repair in Female Mice: Implications for Rapidly Progressive Osteoarthritis 92%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.