Adaptive split ventilator system enables parallel ventilation, individual monitoring and ventilation pressures control for each lung simulators
Shahroor, S. H.; Sarouf, Y.; Oz-Ari, L.; Gilad, M.; k, J.; Leshem, N.; Z, N.; Naor, M.; B, A.; L, R.
Show abstract
ObjectiveIn mass crisis setting such as the COVID-19 pandemic, the number of patients requiring invasive ventilation may exceed the number of available ventilators. This challenge led to the concept of splitting ventilator between several patients, which aroused interest as well as a strong opposition from multiple professional societies (The joint statement)1.Establishment of a safe ventilator splitting setup which enables monitoring and control of each ventilated patient would be a desirable ability. Achieving independency between the Co-vent patients would enable effective coping with different individual clinical scenarios and broaden the pairing possibilities of patients connected to a single ventilator. We conducted an experiment to determine if our designed setup achieves these goals. MethodsWe utilized a double two limbed modified ventilator circuits which were connected to dual lung simulators. Adding readily available pressure sensors (transducers), PEEP valves, flow control valves, one-way (check) valves and HME filters made the circuit safe enough and suitable for our goals. We first examined a single lung simulator establishing the baseline set parameters, while monitoring ventilator measures as Tidal Volume. The initial ventilator setting we chose was a controlled mandatory ventilation mode with a PIP (peak inspiratory pressure) of 25cmH2O, PEEP (Positive End Expiratory Pressure) of 5 cmH2O. In pressure control set at 20 cmH2O, the recorded mean TV(tidal volume) was 1000 mL (approximately 500 mL/lung simulator) with an average MV(minute ventilation) of 13 L/min (or 6.5 L/min/lung simulator). After examining the system with the dual modified circuits attached, and obtaining all the ventilation parameters, we simulated several clinical scenarios. We simulated clinical events such as: partial or full obstruction, disconnection, air leak and compliance differentials, which occur frequently on a ventilation course. Thus, it is a paramount system demand to keep undisturbed ventilation to the Co-vent patient A, while being challenged by patient B. ResultsThe adaptive split ventilator setup yields increased safety, monitoring, and controls ventilation parameters successfully for each connected simulated patient (using lung simulators).It also enables coping with several common clinical scenarios on a ventilation course, by allowing the care provider to control PIP and PEEP of each Co-Vent patient. ConclusionIn a mass crisis setting, when there is a shortage of ventilators supply, and as a last resort, this setup can be a viable option to act upon. This experiment demonstrates the ability of the split ventilator to ventilate dual lung simulators with increased safety, monitoring and ventilation pressures control of each simulated patient. This split ventilator kept supporting a simulated patient with undisturbed parameters while the CO-vent patient was simulated to be disconnected, having an air leak, or exhibiting lung compliance deterioration. To the best of our knowledge, this is the first time a split ventilator setup demonstrates these capabilities. Our pilot experiment suggests a significant potential of expanding the ventilator support resources, and is especially relevant during COVID-19 outbreak. Since this setup has not been used in a clinical setting yet, further research should be conducted to explore the safety limits and the capabilities of this model.
Matching journals
The top 8 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Sharing ventilators in the Covid-19 pandemics. A bench study 96%
- Computational simulation to assess patient safety of uncompensated COVID-19 two-patient ventilator sharing using the Pulse Physiology Engine 95%
- PVP1–The People’s Ventilator Project: A fully open, low-cost, pressure-controlled ventilator 94%
Similar papers in this journal
- Performance of EasyBreath ® Decathlon Snorkeling mask for Delivering Continuous Positive Airway Pressure 95%
- A Cross-sectional Feasibility Study to Evaluate the Usability and Efficacy of “Swaasa”: An AI-Platform for Rapid Respiratory Health Assessment 94%
- Development and Clinical Validation of Swaasa AI Platform for screening and prioritization of Pulmonary TB 92%
Similar papers in this journal
Similar papers in this journal
- A Retrospective Analysis of Feeding Practices and Complications in Patients with Critical Bronchiolitis on Non-invasive Respiratory Support 89%
- Cine phase contrast magnetic resonance imaging of calf muscle contraction in pediatric patients with cerebral palsy and healthy children: comparison of voluntary motion and electrically evoked motion 84%
- Validity and wear compliance of wrist-wearable activity trackers in free-living schoolchildren: validation study 84%
Similar papers in this journal
- Long term impact on lung function of patients with moderate and severe COVID-19. A prospective cohort study 91%
- COVID-19 critical care simulations: An international cross-sectional survey 90%
- Oxygen and mortality in COVID-19 pneumonia: a comparative analysis of supplemental oxygen policies and health outcomes across 26 countries. 89%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.