Single-Acquisition Spectral and Ultra-High-Resolution Pediatric Head CT: Phantom Comparison of Deep-Silicon Photon-Counting and Energy-Integrating Detectors
Feemster, S. G.; Rashidi, A.; Azimi, N.; Yin, Z.; Cherkezyan, L.; Yue, M.; Nett, B. E.; Pourmorteza, A.
Show abstract
Deep-silicon photon-counting CT uses a detector architecture distinct from cadmium-telluride systems and has not been evaluated for pediatric head imaging. To compare attenuation-dependent performance of deep-silicon photon-counting CT (dSi-PCCT) with energy-integrating detector CT (EID-CT) and assess spectral and ultra-high-resolution (UHR) reconstructions from one acquisition. Graded-thickness cranial attenuator and pediatric head phantoms were scanned at a matched target volume CT dose index of 18 mGy. dSi-PCCT used 120 kVp and generated 50-, 65-, and 100-keV images; EID-CT used 80 and 100 kVp. We measured CT-number bias, noise, contrast, and contrast-to-noise ratio (CNR) across 0--9 mm of nominal skull thickness. Mixed-effects models assessed imaging-condition effects. We compared matched standard-resolution and UHR temporal-bone images and generated calcium- and water-density maps from the same dSi-PCCT scan. Noise increased by 4.54%, 3.07%, and 1.35% per millimeter at 50, 65, and 100 keV, respectively, versus 8.38% and 7.84% at 80 and 100 kVp. Corresponding CNR decreases were 4.17%, 3.25%, and 1.75% versus 8.94% and 8.54% (interaction {rho} < 0.001). Changes in absolute CT-number bias and contrast did not differ among conditions ({rho} = 0.92 and {rho} = 0.59). In the pediatric head phantom, model-estimated 50-keV CNR ratios were 1.299 (95% CI, 1.163--1.452) versus 80 kVp and 1.424 (95% CI, 1.275--1.592) versus 100 kVp. Across three temporal-bone edges, UHR transition widths were 58.6%-61.9% narrower than standard-resolution widths. dSi-PCCT maintained CNR more consistently as nominal skull thickness increased and provided complementary spectral and UHR pediatric head images from one acquisition.
Matching journals
The top 5 journals account for 50% of the predicted probability mass.
Similar papers in this journal
Similar papers in this journal
- Reproducible spectral CT thermometry with liver-mimicking phantoms for image-guided thermal ablation 95%
- Patient-derived PixelPrint phantoms for evaluating clinical imaging performance of a deep learning CT reconstruction algorithm 94%
- Precise dose verification in proton therapy using Positron Emission Tomography. 93%
Similar papers in this journal
- First-generation clinical dual-source photon-counting CT: ultra-low dose quantitative spectral imaging 95%
- From Community Acquired Pneumonia to COVID-19: A Deep Learning Based Method for Quantitative Analysis of COVID-19 on thick-section CT Scans 90%
- Observer agreement and clinical significance of chest CT reporting in patients suspected of COVID-19 89%
Similar papers in this journal
- Quality Assurance Assessment of Intra-Acquisition Diffusion-Weighted and T2-Weighted Magnetic Resonance Imaging Registration and Contour Propagation for Head and Neck Cancer Radiotherapy 91%
- PSMA-Hornet: fully-automated, multi-target segmentation of healthy organs in PSMA PET/CT images 91%
- Phase Recognition in Contrast-Enhanced CT Scans based on Deep Learning and Random Sampling 90%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.