Virtual Noncontrast Imaging with Deep-Silicon Photon-Counting CT: Matched Phantom and Initial Human Evaluation
Azimi, N.; Brian-Choux, A.; Feemster, S.; Rahbar, A.; Linder, H.; Crotty, D.; Yin, Z.; Balthazar, P.; Pourmorteza, A.
Show abstract
To compare virtual noncontrast (VNC) error between deep-silicon photon-counting CT (PCCT) and dual-energy energy-integrating detector CT (EID-CT) in a matched phantom and characterize tissue-specific error in humans. This prospective exploratory study included a matched phantom experiment and pilot human evaluation. Prototype projection-domain water-density maps served as the VNC surrogate. Twenty-four vials containing 0.1--20 mg I/mL in deionized water or simulated blood were scanned with PCCT and EID-CT. Three men underwent true noncontrast and contrast-enhanced PCCT; 80 matched measurements were analyzed. Paired t tests and mixed-effects models assessed system differences and iodine associations. Three participants (mean age, 67 {+/-} 10 years; all men) were included. Mean VNC error was 29.1 HU lower with PCCT than EID-CT (95% CI, 15.5--42.7 HU; {rho} < 0.001). Error was not associated with iodine concentration for PCCT (slope, 0.03 HU per mg I/mL; 95% CI, -0.92 to 0.98; {rho} = 0.95) but increased for EID-CT (slope, 3.51 HU per mg I/mL; 95% CI, 2.56--4.46 HU; {rho} < 0.001). The slopes differed by 3.48 HU per mg I/mL ({rho} < 0.001). In humans, errors in five non-blood-pool tissues were within 5 HU. Error was not associated with iodine concentration among 61 non-blood-pool measurements (adjusted slope, -0.17 HU per mg I/mL; 95% CI, -1.22 to 0.88; {rho} = 0.75). PCCT provided VNC measurements with errors closer to zero and less dependent on iodine than EID-CT in the phantom. In humans, error was generally small in non-blood-pool tissues and was not associated with iodine concentration.
Matching journals
The top 4 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Inconsistency of AI in Intracranial Aneurysm Detection with Varying Dose and Image Reconstruction 93%
- Correcting B0 inhomogeneity-induced distortions in whole-body diffusion MRI of bone metastases 90%
- Tracking And Predicting COVID-19 Radiological Trajectory Using Deep Learning On Chest X-Rays: Initial Accuracy Testing 90%
Similar papers in this journal
- PSMA-Hornet: fully-automated, multi-target segmentation of healthy organs in PSMA PET/CT images 93%
- Fully Automated Explainable Abdominal CT Contrast Media Phase Classification Using Organ Segmentation and Machine Learning 90%
- Phase Recognition in Contrast-Enhanced CT Scans based on Deep Learning and Random Sampling 90%
Similar papers in this journal
- Reproducible spectral CT thermometry with liver-mimicking phantoms for image-guided thermal ablation 94%
- Patient-derived PixelPrint phantoms for evaluating clinical imaging performance of a deep learning CT reconstruction algorithm 93%
- Precise dose verification in proton therapy using Positron Emission Tomography. 92%
Similar papers in this journal
- First-generation clinical dual-source photon-counting CT: ultra-low dose quantitative spectral imaging 95%
- From Community Acquired Pneumonia to COVID-19: A Deep Learning Based Method for Quantitative Analysis of COVID-19 on thick-section CT Scans 90%
- Impact of Non-Contrast Enhanced Imaging Input Sequences on the Generation of Virtual Contrast-Enhanced Breast MRI Scans using Neural Networks 90%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.