Multi-Contrast Deep-Silicon Photon-Counting CT for Post-Embolization Imaging: A Quantitative Phantom Study
Azimi, N.; Holmes, T. W.; Brian-Choux, A. R.; Yin, Z.; Crotty, D.; Nezami, N.; Pourmorteza, A.
Show abstract
To evaluate whether eight-bin deep-silicon photon-counting CT can quantify iodine and gadolinium separately and distinguish radiopaque embolic beads from vascular contrast in tumor phantoms. In this phantom study, two-input decomposition of scanner-generated iodine and water images was compared with three- and five-material decomposition of five reconstructed energy-bin images in 56 common test vials, including nine simulated-blood preparations. One tantalum and one bismuth vial were also tested with five-material decomposition. A separately calibrated two-input method using scanner-generated 70-keV and iodine images was applied to four static 3D-printed tumor vascular models: iodine-only and gadolinium-only controls and two models with iodine-containing beads and gadolinium-filled channels. Concentration errors were summarized by bias and root mean square error (RMSE). For iodine, RMSE was 0.40, 0.73, and 1.12 mg I/mL with two-input, three-material, and five-material decomposition, respectively; corresponding gadolinium RMSEs were 0.57, 0.55, and 0.46 mg Gd/mL. Two-input biases were +0.01 mg I/mL and +0.29 mg Gd/mL. Five-material decomposition distinguished tantalum and bismuth in the separate test vials. Beads and vascular gadolinium were spatially separated in the tumor models. In the two bead-containing models, gadolinium measured 32.56 {+/-} 8.02 and 37.02 {+/-} 7.93 mg Gd/mL (mean {+/-} spatial SD), compared with the prepared 35.00 mg Gd/mL. Deep-silicon photon-counting CT separately visualized radiopaque embolic beads and quantified vascular gadolinium from a single acquisition. Recalibrated scanner-generated images supported quantitative dual-contrast imaging, while research energy-bin decomposition distinguished additional materials.
Matching journals
The top 4 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Reproducible spectral CT thermometry with liver-mimicking phantoms for image-guided thermal ablation 96%
- Contrast-enhanced photon-counting micro-CT of tumor xenograft models 94%
- Patient-derived PixelPrint phantoms for evaluating clinical imaging performance of a deep learning CT reconstruction algorithm 94%
Similar papers in this journal
Similar papers in this journal
- PSMA-Hornet: fully-automated, multi-target segmentation of healthy organs in PSMA PET/CT images 93%
- Fully Automated Explainable Abdominal CT Contrast Media Phase Classification Using Organ Segmentation and Machine Learning 91%
- Phase Recognition in Contrast-Enhanced CT Scans based on Deep Learning and Random Sampling 91%
Similar papers in this journal
- First-generation clinical dual-source photon-counting CT: ultra-low dose quantitative spectral imaging 95%
- From Community Acquired Pneumonia to COVID-19: A Deep Learning Based Method for Quantitative Analysis of COVID-19 on thick-section CT Scans 90%
- Impact of Non-Contrast Enhanced Imaging Input Sequences on the Generation of Virtual Contrast-Enhanced Breast MRI Scans using Neural Networks 90%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.