Sensitivity of Pulmonary 4D Flow MRI Biomarkers to Controlled Spatial and Temporal Degradation in a CFD Benchmark
Zubillaga-Unsain, A.; Caballero-Gaudes, C.; Ruiz-Cabello, J.
Show abstract
Purpose: To quantify, in a computational fluid dynamics (CFD) benchmark, how spatial degradation, temporal acquisition and noise change the error of plane-based pulmonary-artery flow endpoints. Methods: Twenty-two historical, non-converged CFD simulations (11 geometry families) were voxelised at 2 mm with 80 frames per cycle. Simulations with numerical divergence were excluded, leaving 13 (7 families). Fields were degraded to 4 and 8 mm and with noise, plane waveforms were sampled at 20 phases with one-interval averaging, and errors were computed against the noise-free reference waveform on 66 geometric planes. Family-mean paired differences are reported with t-based 95% confidence intervals under an analysis plan fixed in advance. Results: Spatial degradation from 2 to 4 mm increased full-waveform nRMSE by 0.0032 [0.0021, 0.0043], in 7 of 7 families; cycle-mean flow bias accounted for 23% of the squared error, against 60% at 8 mm. With SNR scaled to voxel volume, the increase was not resolved (0.0002 [-0.0012, 0.0015]). Twenty-phase acquisition increased PI error (0.0223 [0.0214, 0.0233]) and diastolic-trough timing error (0.63 [0.52, 0.74] frames) more than spatial degradation, and its point estimates for these endpoints were larger with every recovery method; the nRMSE ordering and peak timing depended on the recovery method. The implementation of the downsampling operator mattered: an alternative, corner-aligned implementation of the same 4 mm degradation gave a larger spatial effect (nRMSE difference 0.0010 [0.0002, 0.0017]). Conclusion: In this benchmark, a 2 to 4 mm degradation produced a small, consistent, mostly shape-related nRMSE increase that depended on the noise model, whereas 20-phase acquisition changed PI error and trough timing more. The results describe benchmark behaviour, not clinical acquisition requirements.
Matching journals
The top 4 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Highly Accelerated Vessel-Selective Arterial Spin Labelling Angiography using Sparsity and Smoothness Constraints 94%
- Simulation-informed evaluation of microvascular parameter mapping for diffusion MR imaging of solid tumours 94%
- Deep Learning Based Cardiac Cine Segmentation – Transfer Learning Application to 7T Ultrahigh-Field MRI 93%
Similar papers in this journal
- Uncertainty in cardiovascular digital twins despite non-normal errors in 4D flow MRI: identifying reliable biomarkers such as ventricular relaxation rate 93%
- Aortic annuloplasty FSI digital twin of 3D-printed phantoms with 4D-flow MRI comparison 93%
- In-silico heart model phantom to validate cardiac strain imaging 92%
Similar papers in this journal
- Reproducibility of 4D Flow MRI-based Personalized Cardiovascular Models; Inter-sequence, Intra-observer, and Inter-observer variability 94%
- Diffusion tensor imaging and arterial tissue: establishing the influence of arterial tissue microstructure on fractional anisotropy, mean diffusivity and tractography 92%
- Does contrast-enhancement improve visualisation of lenticulostriate arteries in cerebral small vessel disease using time-of-flight magnetic resonance angiography at 7 Tesla? 92%
Similar papers in this journal
- Multi-modal Monte Carlo MRI simulator of tissue microstructure 92%
- BOLDsωimsuite: A new software suite for forward modeling of the BOLD fMRI signal 91%
- Visual stimulus-evoked blood velocity responses in individual human posterior cerebral arteries measured with dynamic phase-contrast functional MR angiography 91%
Similar papers in this journal
- Fluid and White Matter Suppression Contrasts MRI Improves Deep Learning Detection of Multiple Sclerosis Cortical Lesions 90%
- QSMRim-Net: Imbalance-Aware Learning for Identification of Chronic Active Multiple Sclerosis Lesions on Quantitative Susceptibility Maps 90%
- Meningioma microstructure assessed by diffusion MRI: an investigation of the source of mean diffusivity and fractional anisotropy by quantitative histology 87%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.