Reclassifying Ablation Energy Risk Profiles in Atrial Fibrillation: A Narrative-Adjudicated Comparative Analysis of the MAUDE Database
Shah, A. S.; Fuller, R.; Daoud, E. G.; Endo, B.; Goodwin, A.; Martinez-Parachini, R.; Engels, M.; Lehmann, H. I.; Konstantinidis, K.; Ranjan, R.; Bunch, T. J.
Show abstract
Background: Pulsed field ablation (PFA) has been rapidly adopted for atrial fibrillation (AF) on the premise of greater safety than thermal ablation. Real-world signals of hemolysis, coronary spasm, and neurologic events have since emerged, and prior Manufacturer and User Facility Device Experience (MAUDE) analyses relied on term matching without prospective signal detection. Methods: We queried MAUDE for AF ablation catheter reports received January 2016 through June 2026 and assigned each to PFA, radiofrequency ablation (RFA), or cryoballoon ablation. We adjudicated injury and death narratives into predefined complication families and severity tiers with a large language model, checked against a larger model and by physician review. We calculated reporting odds ratios (ROR) and Bayesian shrinkage estimators compared against an empirical null, applied interrupted time series and prospective sequential detection, and repeated estimates on a 2026 hold-out. Results: Among 44,623 reports, 30.1% were PFA, 50.9% RFA, and 19.0% cryoballoon, with 91.8% model agreement on event occurrence (? = 0.83). PFA carried an ROR of 527 (95% CI, 33, 8,509) for hemolysis, 2.83 (2.55, 3.16) for arrhythmia, 2.83 (2.30, 3.48) for coronary, and 2.39 (2.10, 2.73) for cerebrovascular events, against 0.024 (0.008, 0.075) for esophageal and 0.34 (0.32, 0.37) for pericardial events. The cerebrovascular excess was largest for VARIPULSE, but without it the class proportional reporting ratio was 1.36 (1.13, 1.65), concordant with the 1.56 measured in EMBOL-AF. In the hold-out, the cerebrovascular, arrhythmia and hemolysis signals replicated, and coronary events kept their direction without meeting the signal rule. Prospective detection flagged cerebrovascular events 13 months before AVANT GUARD published its neurologic events. Conclusions: PFA showed disproportionate reporting of hemolysis, cerebrovascular, coronary, and arrhythmic events across sequential testing. Machine learning methods allowed for flagging these signals months before confirmatory trials, demonstrating a scalable tool for early detection of procedural risk.
Matching journals
The top 4 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Multicenter analysis of atrioesophageal fistula rates before and after adoption of active esophageal cooling during atrial fibrillation ablation 96%
- Enhancing Ventricular Tachycardia Ablation Outcomes: The Impact Of Functional Mapping In Chagas Cardiomyopathy 94%
- Peri-Procedural Intravascular Hemolysis during Atrial Fibrillation Ablation: A Comparison of Pulsed-Field with Radiofrequency Ablation 94%
Similar papers in this journal
Similar papers in this journal
- Procedural Volume and Outcomes with Atrial Fibrillation Ablation: A Report from the NCDR AFib Ablation Registry 95%
- Linking the Heart-Eye-Brain Axis: Ocular and Cerebral Blood Flow After Catheter Ablation in Atrial Fibrillation 94%
- A Novel Temperature Controlled Bipolar Radiofrequency Ablation: An Ex Vivo Study for Optimizing Efficacy and Safety Parameters 93%
Similar papers in this journal
- Surgical strategy for atrial functional mitral regurgitation with atrial fibrillation 92%
- Mineralocorticoid Receptor Antagonism Reduces Atrial Arrhythmias Post-Cardiac Surgery and Attenuates Atrial Stress Responses to Cardioplegic Arrest 92%
- Smartwatch Facilitated Remote Health Care for Patients Undergoing Transcatheter Aortic Valve Replacement Amid COVID-19 Pandemic 91%
Similar papers in this journal
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.