Safety, usability, patient comfort, and exploratory biofilm outcomes of the superhydrophilic antifouling LubriShield(R) Foley catheter: a randomised controlled trial
Romero, A. I.; Madhusudhan, S.; Krishnakumar, M.; Sambasivam, R.; Surkov, S.; Wirsen, P.; Bergström, L.; Brookes, G.; Leire, K.; Andersson, J.
Show abstract
Background: Indwelling urinary catheters can cause pain, urethral irritation and trauma and provide surfaces for microbial colonisation and biofilm formation. The LubriShield(R) Foley catheter incorporates a covalently bonded, superhydrophilic antifouling hydrogel designed to reduce surface friction and limit biofilm accumulation without releasing an antimicrobial agent. This study evaluated its safety and clinical performance compared with an uncoated silicone Foley catheter, including usability and patient comfort, and explored catheter-associated microbial colonisation and biofilm formation. Methods: This prospective, randomised, single-blind, single-centre controlled clinical investigation enrolled 33 adults requiring indwelling urinary catheterisation for 72 hours to 14 days. Participants received either the LubriShield(R) Foley catheter (n = 16) or an uncoated Sterimed all-silicone Foley catheter (n = 17). The primary endpoint was safety based on adverse-event reporting; the prespecified safety criterion was the absence of a serious adverse device effect in the LubriShield(R) group. Secondary endpoints included investigator-rated ease and functionality of catheter insertion and removal and participant-reported pain and irritation/discomfort assessed using 0-10 numerical rating scales. Urine microbiology, catheter colonisation and catheter-level biofilm measurements were exploratory endpoints. Analyses were performed in the as-treated population. Numerical rating scale outcomes were compared using two-sided Mann-Whitney U tests; exploratory biofilm analyses used permutation tests with bootstrap confidence intervals. Results: No serious adverse events or serious adverse device effects occurred. Nine non-serious adverse events were reported and resolved completely. At least one adverse event occurred in 4/16 (25.0%) participants in the LubriShield(R) group and 4/17 (23.5%) participants in the control group. The prespecified safety criterion, defined as the absence of a SADE in the LubriShield(R) group, was met. LubriShield(R) was rated more favourably for ease of insertion (p = 0.0096), functionality during insertion (p = 0.0051), ease of removal (p = 0.0037) and functionality during removal (p = 0.0085). Participants reported significantly less pain and irritation/discomfort during insertion, while the catheter was indwelling and during removal (all p < 0.05). Outcomes 7 {+/-} 1 days after catheter removal were similar between groups. Absolute biofilm biomass and bacterial and fungal loads did not differ significantly. In a post hoc exploratory normalised analysis, the biofilm-to-bacterial-load ratio was lower with LubriShield(R) (median 0.052 vs 0.080; permutation p = 0.043), although the bootstrap 95% confidence interval for the between-group difference included zero. Conclusions: The LubriShield(R) Foley catheter demonstrated a favourable short-term safety profile and was associated with improved investigator-rated usability and participant-reported comfort compared with an uncoated silicone Foley catheter. A post hoc exploratory analysis was compatible with reduced biofilm accumulation relative to bacterial load, but this finding is hypothesis-generating only and requires confirmation in larger, adequately powered studies with prespecified biofilm endpoints.
Matching journals
The top 6 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Reliability and Performance of the IRRAflow® System for Intracranial Lavage and Evacuation of Hematomas - A Technical Note 92%
- Care Of Peripheral Intravenous Catheters In Three Hospitals In Spain: Mapping Clinical Outcomes And Implementation Of Clinical Practice Guidelines 91%
- Randomised, controlled, feasibility trial comparing vasopressor infusion administered via peripheral cannula versus central venous catheter for critically ill adults: a study protocol 91%
Similar papers in this journal
- Factors influencing plasma galectin-3 concentrations in catheter-bearing hospitalized patients 89%
- Preclinical and clinical validation of a novel injected molded swab for molecular assay detection of SARS-CoV-2 virus 87%
- Reducing the Cost of Rapid Antigen Tests through Swab Pooling and Extraction in a Device 85%
Similar papers in this journal
- Development And Characterization Of A New Endoscopic Drug Eluting Platform With Proven Efficacy In Acute And Chronic Experimental Colitis 88%
- Combining Bacteriophage and Vancomycin is Efficacious Against MRSA biofilm-like Aggregates Formed in Synovial Fluid 87%
- A Predictive Nomogram for In-ICU Deterioration of Stage 1 Pressure Injuries: A Retrospective Study 87%
Similar papers in this journal
- Validity of intraoperative imageless navigation (Naviswiss™) for component positioning accuracy in primary total hip arthroplasty: Protocol for a prospective observational cohort study in a single-surgeon practice 90%
- Criteria to Achieve Safe Antimicrobial Intravenous-to-Oral Switch in Hospitalised Adult Populations: A Systematic Rapid Review 89%
- Prescribing patterns for medical treatment of suspected prostatic obstruction: A spatiotemporal statistical analysis of Scottish open access data 89%
Similar papers in this journal
- Does Copper treating of commonly touched surfaces reduce healthcare acquired infections? A Systematic Review and meta-analysis 91%
- Cleaning and disinfecting surfaces in hospitals and long-term care facilities for reducing hospital and facility-acquired bacterial and viral infections: A systematic review 89%
- In vitro and in situ analysis of a novel copper-based antimicrobial surface coating designed to reduce the microbial bioburden of high touch surfaces in a hospital environment. 88%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.