Back

Wavelet Transform improves time-frequency characterization of the Electroretinographic Oscillatory Potentials as compared to Short-Time Fourier Transform across experimental and clinical models

Reiman, P.; Ghiam, S.; Beryozkin, A.; Stein Uman, V.; Sahel, A.; Mouillet, J.-F.; Janeschitz-Kriegl, L.; Safran, J.; Shemuelian, E.; Beale, O.; Khateb, S.; Ayalon, A.; Hagan, R.; Liasis, A.; Stavropoulos, D.; Chang, K.-C.; Kuwajima, T.; Mehta, K.; Aldiri, I.; Caspi, A.; Audo, I.; Banin, E.; Sahel, J.-A.; Rosin, B.

2026-10-02 physiology
10.64898/2026.09.26.754708 bioRxiv
Show abstract

Purpose: To compare continuous wavelet transform (CWT) and short-time Fourier transform (STFT) analyses of the oscillatory potentials (OPs) of the dark-adapted full-field electroretinogram (FFERG). Methods: FFERG recordings from Royal College of Surgeons (RCS) and healthy Brown Norway (BN) rats, wild-type and Atoh7 enhancer-knockout (KO) mice, and patients with diabetic retinopathy and healthy controls were analyzed with STFT and with CWT employing the real Morlet wavelet, after 60 Hz high-pass and sharp 60 Hz notch filtering. Time- and frequency-localized OP features were quantified and the methods compared on detection of transient OP signals. Both were additionally validated using synthetic OP-like bursts of known frequency embedded in each cohort's recorded noise. Results: CWT revealed distinct time-frequency patterns and disease-specific OP alterations across all rat, mouse, and human cohorts, with improved temporal localization and frequency resolution, whereas STFT merged transient features and was more susceptible to noise. CWT-derived dominant-frequency differences reached significance in all three models; the corresponding STFT difference reached significance only in rats (separate tests; methods not directly compared). In synthetic bursts, both methods recovered injected frequencies to within 1-2.5 Hz, but only CWT resolved two bursts separated by 15 ms. Conclusions: CWT employing the real Morlet wavelet provides a robust, physiologically relevant evaluation of OPs, with improved temporal localization and reduced spectral dispersion relative to STFT in clinical and experimental settings. Translational Relevance: CWT analysis may improve the characterization of inner retinal dysfunction by preserving transient OP time-frequency structure, as illustrated in preclinical rodent models and diabetic retinopathy patients.

Matching journals

The top 5 journals account for 50% of the predicted probability mass.

50% of probability mass above

"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.