A Physics-Informed Neural Network Surrogate for Patient-Specific Hepatic Arterial Hemodynamics in Yttrium-90 Radioembolization: Network Architecture, Boundary-Condition Enforcement, and Data Efficiency
Taatizadeh, E.; Panneer Selvam, N. K.; Roncali, E.
Show abstract
Trans-arterial radioembolization using yttrium-90 (Y-90) microspheres treats unresectable liver cancer with radiation. The tumor-to-parenchyma dose ratio is mainly governed by the patient-specific hepatic arterial flow distribution, which transports the microspheres. Even though computational fluid dynamics (CFD) simulation can predict this flow distribution, its high computational cost and time limit intraprocedural application. To overcome this computational limitation, a physics-informed neural network (PINN) surrogate was developed to provide rapid predictions of flow distribution in a patient-specific hepatic artery model. The surrogate maps spatial coordinates to the velocity vector U with Cartesian components u, v, w and the static pressure p. Reference velocity and pressure fields came from a converged finite-element CFD solve of the same geometry at about 1.05 x 105 nodes; a controlled fraction was used to supervise the training while the remainder was held out for validation. Using the NVIDIA PhysicsNeMo framework, we compared four coordinate networks (MLP, Modified Fourier, Multi-Scale Fourier and SIREN) under soft and hard inlet enforcement across a supervised data sweep (data fraction df = 0 to 0.20) and repeated df = 0.20 at a matched 300,000-step budget. Predicted flow splits were propagated through an established Y-90 dose-kernel pipeline. Accuracy is governed primarily by the supervised-data fraction, not the architecture: at df [≥] 0.10 the backbones agree to within one to two R2 points, and R2(u) rises from {approx} 0 under pure physics (df = 0) to {approx} 0.95 by df = 0.01 for the best backbones, saturating near 0.97 to 0.99 by df = 0.20. At a matched 300,000-step budget the Multi-Scale Fourier network leads (R2(u) = 0.978) ahead of SIREN (R2(u) = 0.976) and the MLP (R2(u) = 0.968); the best value seen (R2(u) = 0.985, Modified Fourier) needed 1.8 times that budget. On the df = 0.20 checkpoint the per-outlet flow split matches CFD (r = 0.999, L1 = 4.4 percentage points) and the derived dosimetry agrees to within 2.4% for perfused volume, mean dose and every isodose volume. At df = 0 training collapses toward the trivial near-zero state, which satisfies continuity, momentum and the zero-pressure outlets exactly and is ruled out only by the inlet and data terms; this, not architecture choice, is the limiting failure mode. Once trained, the network evaluates the full 105,284-node field in about 2 s on a four-core CPU. The supervised-data fraction, with a practical floor between df = 0.05 and 0.10, is the primary design lever for such hepatic-arterial PINN surrogates.
Matching journals
The top 8 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Precise dose verification in proton therapy using Positron Emission Tomography. 93%
- Development of a Coupled Simulation Toolkit for Computational Radiation Biology Based on Geant4 and CompuCell3D 92%
- High precision fluorescence tomography-guided system for pre-clinical radiation research: system design and validation 92%
Similar papers in this journal
- Quality Assurance Assessment of Intra-Acquisition Diffusion-Weighted and T2-Weighted Magnetic Resonance Imaging Registration and Contour Propagation for Head and Neck Cancer Radiotherapy 93%
- Evaluation of inverse treatment planning for Gamma Knife radiosurgery using fMRI brain activation maps as organs at risk 93%
- PSMA-Hornet: fully-automated, multi-target segmentation of healthy organs in PSMA PET/CT images 92%
Similar papers in this journal
Similar papers in this journal
- Enhanced perfusion following exposure to radiotherapy: a theoretical investigation 93%
- Radiation necrosis after radiation therapy treatment of brain metastases: A computational approach 93%
- Combining Hypoxia-Activated Prodrugs and Radiotherapy in silico: Impact of Treatment Scheduling and the Intra-Tumoural Oxygen Landscape 90%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.