No Strings Attached: Predicting Tricuspid Valve Deformation Without In Vivo Chordal Geometry
Mathur, M.; Haese, C. E.; Dubey, V. K.; Seetharam, S.; Meador, W. D.; Jazwiec, T.; Simonian, N. T.; Sacks, M. S.; Malinowski, M.; Fuhg, J.; Moussa, I.; Cohen, J. A.; Summers, M. R.; Timek, T. A.; Hiesinger, W.; Rausch, M. K.
Show abstract
Predictive biomechanical models of the tricuspid valve require accurate representation of the chordae tendineae, yet subject-specific chordal geometry is difficult to reconstruct from non-invasive imaging. Here, we adopt a framework for generating functionally equivalent synthetic chordae without prior knowledge of in vivo chordal attachments. To this end, we first adapt an anatomy-informed hyperelastic shape-matching method that establishes correspondence between end-diastolic and end-systolic leaflet configurations using chordal-mimicking forces, a rigid contact template, and a Gaussian-smoothed locally corrective pressure field. We then generate synthetic chordal insertion sites using zone-based rejection sampling and calibrate the unloaded length of each chord by combining reaction forces with the chordal stress-stretch relationship. The framework was evaluated using Texas TriValve 1.1, a high-fidelity finite element model of a human tricuspid valve validated against beating-heart echocardiography. We found that shape matching reproduced the target end-systolic geometry with a mean inter-surface distance of 0.29 {+/-} 0.35 mm. Moreover, synthetic chordal insertions faithfully reproduce end-systolic leaflet deformations. We subsequently examined synthetic chordal configurations containing 202, 225, and 450 insertions, informed by measurements from eight explanted human tricuspid valves. Here, increasing insertion number reduced mean inter-surface distance from 0.63 {+/-} 0.52 mm to 0.49 {+/-} 0.44 mm and reduced contact area errors from 3.52% to 0.59%. Across all configurations, mean maximum principal stretch errors in leaflet belly regions remained below 2.4%, while areal strain errors ranged from 0.34% to 10.01%. These results demonstrate that anatomically informed shape matching coupled with stress-based chordal calibration can reproduce tricuspid valve closure without explicit subject-specific chordal geometry. This framework provides a foundation for generating synthetic subvalvular anatomy for future imaging-derived, predictive tricuspid valve models.
Matching journals
The top 6 journals account for 50% of the predicted probability mass.
Similar papers in this journal
Similar papers in this journal
- Integrated multi-modal data analysis for computational modeling of healthy and location-dependent myocardial infarction conditions in porcine hearts 95%
- Systematic computational assessment of atrial function impairment due to fibrotic remodeling in electromechanical properties 94%
- The Geometric Evolution of Aortic Dissections: Predicting Surgical Success using Fluctuations in Integrated Gaussian Curvature 94%
Similar papers in this journal
- Multiscale Multimodal Characterization and Simulation of Structural Alterations in Failed Bioprosthetic Heart Valves 93%
- Tricuspid valve leaflet remodeling in sheep with biventricular heart failure: A comparison between leaflets 93%
- Characterization of pediatric porcine pulmonary valves as a model for tissue engineered heart valves 92%
Similar papers in this journal
- Model order reduction for left ventricular mechanics via congruency training 95%
- Mechanical effects of MitraClip on leaflet stress and myocardial strain in functional mitral regurgitation: A finite element modeling study. 93%
- Ventricular anatomical complexity and gender differences impact predictions from computational models 93%
Similar papers in this journal
- A comprehensive stroke risk assessment by combining atrial computational fluid dynamics simulations and functional patient data 93%
- A simple approach for image-based modelling of the heart that enables robust simulation of highly heterogeneous electrical excitation. 93%
- Reproducibility of 4D Flow MRI-based Personalized Cardiovascular Models; Inter-sequence, Intra-observer, and Inter-observer variability 92%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.