Enhancing the Clinical Utility of Renal Denervation Through Efficient Physiologic Monitoring
Shad, K.; Schiller, A. M.; Zucker, I. H.; Chatzizisis, Y. S.; Wang, H.; Pellegrino, P. R.
Show abstract
Introduction: The inability to measure renal sympathetic outflow clinically poses a significant problem for patient identification and intraprocedural feedback for renal denervation. Sympathetic vasomotion is a novel physiologic measure of rhythmic vascular control that reflects renal sympathetic nervous system activity, but previous measurements of sympathetic vasomotion relied on 15-minute data recordings, which may be impractical in many clinical settings. We therefore tested whether shorter data segments can provide reliable sympathetic vasomotion assessment to enhance decision making for renal denervation. Methods: Ten swine that had previously undergone unilateral surgical renal denervation underwent four rounds of catheter-based denervation of the contralateral kidney. Sympathetic vasomotion was quantified from the time-varying arterial pressure-resistive renal blood flow transfer function of recordings obtained before and after each round of ablation. Randomly placed 1- to 14-minute data segments were scored and compared with the corresponding 15-minute sympathetic vasomotion scores across 100 passes using correlation, intraclass correlation, error, and Bland-Altman agreement metrics, and by whether they reproduced the denervation decisions made from the full recordings. Results: Agreement with the 15-minute reference score improved steeply with recording length up to approximately four minutes and slowly thereafter, with the point of diminishing returns at four minutes for every group-level measure. Four-minute data segments showed an intraclass correlation coefficient of 0.94, reproduced the group-level statistical results across ablations, and preserved intraprocedural denervation decisions. Bland-Altman analysis revealed that individual-level precision continued to improve with recording length; the proportion of scores falling within a quarter of the average difference between innervated and denervated kidneys at baseline was 65 percent at four minutes and 96 percent at ten minutes. Discussion: Four-minute data segments provide a feasible minimum recording duration when the question is a group comparison or a paired, within-individual decision, such as intraprocedural confirmation that an innervated kidney has shifted toward a denervated state. When a single score must be interpreted on its own, as in preprocedural patient selection, ten-minute recordings provide greater precision. Further studies are needed to prospectively evaluate sympathetic vasomotion in clinical settings and determine whether this technology can support procedural feedback and inform patient selection.
Matching journals
The top 5 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Reliability and Performance of the IRRAflow® System for Intracranial Lavage and Evacuation of Hematomas - A Technical Note 92%
- Validation of deep learning enabled web based and smartphone optimized application RadAnalyzer to measure vertebral heart size and vertebral left atrial size in dogs 91%
- Evaluating the kidney disease progression using a comprehensive patient profiling algorithm: A hybrid clustering approach 91%
Similar papers in this journal
- The assessment of cortical hemodynamical responses induced by tubuloglomerular feedback using in vivo imaging 93%
- Potential Relationship Between eGFR cystatin C /eGFR creatinine -ratio and Glomerular Basement Membrane Thickness in Diabetic Kidney Disease 91%
- Glenn circulation causes early and progressive shunting in a surgical model of pulmonary arteriovenous malformations 88%
Similar papers in this journal
Similar papers in this journal
- Cardiac Output During Exercise: Thermodilution versus Direct Fick 92%
- Non-Invasive Scale Measurement of Cardiac Output Compared with the Gold-Standard Direct Fick Method: A Feasibility Study 92%
- iCPET calculator: a web-based application to standardize the calculation of alpha distensibility in patients with pulmonary arterial hypertension 91%
Similar papers in this journal
- Correlating Deep Learning-Based Automated Reference Kidney Histomorphometry with Patient Demographics and Creatinine 93%
- Packed Red Blood Cell and Whole Blood Perfusates during an Ex-vivo Normothermic Perfusion for Assessment of High-Risk Donor Kidneys 92%
- Development and Validation of a Web-based Prediction Model for Acute Kidney Injury after surgery 92%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.