Evaluations of retrospective frequency and phase correction methods for single-voxel MR spectroscopy at 7T
Lee, C.-Y.; Xu, J.; Yang, B.; Noeske, R.; Magnotta, V.
Show abstract
Subject motion and gradient heating-induced frequency and phase offsets result in spectral misalignment during single-voxel MR spectroscopy (SVS) acquisitions. Several methods have been presented to align the spectra, but their performance on a 7T system is unclear. This study aimed to evaluate the practical importance of four retrospective correction methods, namely creatine fitting, residual water, spectral registration, and cross-correlation. SVS data were collected from 127 participants (88/39 female/male, 39{+/-}15 years) using a semi-localization by adiabatic selective refocusing sequence at 7T. Changes in the spectral linewidth, signal-to-noise ratio (SNR), similarity (mean similarity matrix (SImean)), and metabolite quantification (concentration, relative Cramer-Rao lower bounds (rCRLB)) after correction were evaluated. A Wilcoxon signed rank test was used to evaluate these changes. The p-values were adjusted using the false discovery rate (q<0.05) for multiple comparisons. For significant changes, the effect size was further calculated using the Rosenthal formula. The results demonstrated that all correction methods resulted in a significant decrease in the spectral linewidth and significant increases in the spectral SNR and SImean. The mean changes by using the four methods were 0.76-0.99 Hz for the spectral linewidth change (effect sizes:0.73-0.86), 5.79-6.95 for the SNR change (effect size:0.60-0.72), and 0.03-0.03 for the SImean change (effect size:0.87-0.87). The correction also significantly increased the estimates of the metabolite concentrations of PCr, Gln, Glu, GPC, Ins, NAA, Scyllo, and Tau (effect size:0.25-0.57), and significantly decreased the rCRLBs (effect size:0.26-0.42) of Scyllo, Tau, and Gly. These results indicate that each method provides practical benefits in improving the spectral linewidth, SNR, and similarity by showing a strong to very strong effect of the improvements (effect size>0.60). The correction only showed a weak to moderate effect of the changes in the metabolite quantification (effect size<0.60), suggesting that whether the correction results in more reliable metabolite quantification requires further validation.
Matching journals
The top 1 journal accounts for 50% of the predicted probability mass.
Similar papers in this journal
Similar papers in this journal
Similar papers in this journal
- Test-retest reproducibility of in vivo magnetization transfer ratio and saturation index in mice at 9.4 Tesla 94%
- Correction of Artifacts Induced by B0 Inhomogeneities in Breast MRI using Reduced Field-of-View Echo-Planar Imaging and Enhanced Reverse Polarity Gradient Method 94%
- AI-powered Gradient Echo Plural Contrast Imaging (AI-GEPCI): a Comprehensive Multiparametric Neurological Protocol from a Single MRI Scan 93%
Similar papers in this journal
- GABA quantification in human anterior cingulate cortex 95%
- Increased brain coverage and efficiency when measuring current-induced magnetic fields by use of simultaneous multi-slice echo-planar MRI 94%
- Acceleration of chemical shift encoding-based water fat MRI for liver proton density fat fraction and T2* mapping using compressed sensing 94%
Similar papers in this journal
- Quantitative T1-relaxation corrected metabolite mapping of 12 metabolites in the human brain at 9.4 T 95%
- The dot-compartment revealed? Diffusion MRI with ultra-strong gradients and spherical tensor encoding in the living human brain 94%
- Detection of Nanoliter-Scale Cortical Perivascular Spaces Using Heavily T2-weighted MRI at 7T 94%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.